| Literature DB >> 24923279 |
Mareike Simon1, Ludger Keilig, Jörg Schwarze, Britta A Jung, Christoph Bourauel.
Abstract
BACKGROUND: The aim of this study was to investigate the efficacy of orthodontic treatment using the Invisalign® system. Particularly, we analyzed the influence of auxiliaries (Attachment/Power Ridge) as well as the staging (movement per aligner) on treatment efficacy.Entities:
Mesh:
Year: 2014 PMID: 24923279 PMCID: PMC4068978 DOI: 10.1186/1472-6831-14-68
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Amount of planned movement
| Premolar Derotation w Att | 2.0° | 30.0° | 17.8° | 1.1° |
| Premolar Derotation w/o Att | 2.0° | 35.0° | 20.1° | 1.2° |
| Distalization w Att | 0.25 mm | 3.2 mm | 2.7 mm | 0.2 mm |
| Distalization w/o Att | 0.25 mm | 3.2 mm | 2.6 mm | 0.2 mm |
| Incisor Torque w Att | 1.0° | 28.0° | 16.1° | 1.2° |
| Incisor Torque w PR | 1.0° | 30.0° | 15.9° | 1.1° |
w Att. = with Attachment; w/o Att. = without Attachment; w PR = with Power Ridge.
*Possible staging according to the treatment protocol of Align technology.
**Amount of planned movement according to ClinCheck/the technician.
Figure 1Laser scanner used in this study.
Figure 2Superimposition of the scans. a) The plaster cast models of the beginning conditions are digitised using a laser scanner. b) The models are segmented into single teeth. c) The predicted tooth movement in the ClinCheck (extracted from the dataset from Align Technology). d) Superimposition of the plaster cast of the beginning conditions with the ending conditions in the ClinCheck to determine the predicted tooth movement.
Figure 3Definition of the coordinate system used in this work. The distalization is described as a translation on the x-axis, incisor torque as a rotation around the y-axis, and premolar derotation is described as a rotation around the z-axis.
Figure 4Box– whisker plots showing the treatment efficacy of incisor torque, premolar derotation and molar distalization. w. Att = with Attachment, w/o Att = without Attachment, w. PR. = With Power Ridge.
Accuracy of tooth movements
| Premolar Derotation w Att | 37.5 | 80.6 | - 2.9 | 0.3 | 0.00 |
| Premolar Derotation w/o Att | 42.4 | 79.8 | 23.6 | 0.3 | 0.02 |
| Distalization w Att | 88.4 | 108.7 | 56.4 | 0.2 | 0.38 |
| Distalization w/o Att | 86.9 | 104.2 | 61.0 | 0.2 | 0.46 |
| Incisor Torque w Att | 49.1 | 71.6 | 29.9 | 0.2 | 0.00 |
| Incisor Torque w PR | 51.5 | 75.1 | 27.4 | 0.2 | 0.00 |
w Att. = with Attachment; w/o Att. = without Attachment; w PR = with Power Ridge.
p-value = clinically achieved tooth movement (T2) – tooth movement predicted by ClinCheck (Clin T2), p < 0.05.
Accuracy of premolar derotation according to the amount of planned tooth movement
| Premolar Derotation < 15° | 43.3 | 72.5 | 16.8 | 0.24 |
| Premolar Derotation > 15° | 23.6 | 76.9 | -2.9 | 0.15 |
Accuracy of premolar derotation according to the staging (movement/aligner)
| Premolar Derotation | < 1.5° | 41.8 | 0.3 |
| Premolar Derotation | > 1.5° | 23.2 | 0.2 |