Impact of anti-charge sharing on the zero-frequency detective quantum efficiency of CdTe-based photon counting detector system: cascaded systems analysis and experimental validation.

Xu Ji1, Ran Zhang, Guang-Hong Chen, Ke Li.   

Abstract

Inter-pixel communication and anti-charge sharing (ACS) technologies have been introduced to photon counting detector (PCD) systems to address the undesirable charge sharing problem. In addition to improving the energy resolution of PCD, ACS may also influence other aspects of PCD performance such as detector multiplicity (i.e. the number of pixels triggered by each interacted photon) and detective quantum efficiency (DQE). In this work, a theoretical model was developed to address how ACS impacts the multiplicity and zero-frequency DQE [DQE(0)] of PCD systems. The work focused on cadmium telluride (CdTe)-based PCD that often involves the generation and transport of K-fluorescence photons. Under the parallel cascaded systems analysis framework, the theory takes both photoelectric and scattering effects into account, and it also considers both the reabsorption and escape of photons. In a new theoretical treatment of ACS, it was considered as a modified version of the conventional single pixel (i.e. non-ACS) mode, but with reduced charge spreading distance and K-fluorescence travel distance. The proposed theoretical model does not require prior knowledge of the detailed ACS implementation method for each specific PCD, and its parameters can be experimentally determined using a radioisotope without invoking any Monte-Carlo simulation. After determining the model parameters, independent validation experiments were performed using a diagnostic x-ray tube and four different polychromatic beams (from 50 to 120 kVp). Both the theoretical and experimental results demonstrate that ACS increased the first and second moments of multiplicity for a majority of the x-ray energy and threshold levels tested, except when the threshold level was much lower than the x-ray energy level. However, ACS always improved DQE(0) at all energy and threshold levels tested.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29582785      PMCID: PMC5975362          DOI: 10.1088/1361-6560/aab9c9

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  45 in total

1.  Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.

Authors:  Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

2.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

3.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

4.  Detective quantum efficiency of photon-counting x-ray detectors.

Authors:  Jesse Tanguay; Seungman Yun; Ho Kyung Kim; Ian A Cunningham
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

5.  Photon-counting CT for simultaneous imaging of multiple contrast agents in the abdomen: An in vivo study.

Authors:  Rolf Symons; Bernhard Krauss; Pooyan Sahbaee; Tyler E Cork; Manu N Lakshmanan; David A Bluemke; Amir Pourmorteza
Journal:  Med Phys       Date:  2017-08-20       Impact factor: 4.071

6.  Fundamental relationship between the noise properties of grating-based differential phase contrast CT and absorption CT: theoretical framework using a cascaded system model and experimental validation.

Authors:  Ke Li; Nicholas Bevins; Joseph Zambelli; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

7.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

8.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems.

Authors:  I A Cunningham; M S Westmore; A Fenster
Journal:  Med Phys       Date:  1994-03       Impact factor: 4.071

9.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application.

Authors:  Polad M Shikhaliev; Shannon G Fritz
Journal:  Phys Med Biol       Date:  2011-03-02       Impact factor: 3.609

10.  Dual-Source Multi-Energy CT with Triple or Quadruple X-ray Beams.

Authors:  Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22
View more
  4 in total

1.  Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning.

Authors:  Joakim da Silva; Fredrik Grönberg; Björn Cederström; Mats Persson; Martin Sjölin; Zlatan Alagic; Robert Bujila; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-15

2.  Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication.

Authors:  Xu Ji; Kevin Treb; Ke Li
Journal:  Phys Med Biol       Date:  2021-04-14       Impact factor: 3.609

3.  Task-driven optimization of the non-spectral mode of photon counting CT for intracranial hemorrhage assessment.

Authors:  Xu Ji; Ran Zhang; Guang-Hong Chen; Ke Li
Journal:  Phys Med Biol       Date:  2019-10-31       Impact factor: 3.609

4.  Frequency-dependent signal and noise in spectroscopic x-ray imaging.

Authors:  Jesse Tanguay; Jinwoo Kim; Ho Kyung Kim; Kris Iniewski; Ian A Cunningham
Journal:  Med Phys       Date:  2020-04-22       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.