Literature DB >> 29520045

Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer.

Wenwen He1,2,3, Xiaodi Qiu1,2,3, Shaohua Zhang1,2,3, Yu Du1,2,3, Yinglei Zhang1,2,3, Yi Lu4,5,6, Xiangjia Zhu7,8,9.   

Abstract

PURPOSE: To compare the long-term decentration and tilt in two multifocal intraocular lenses (MfIOLs) with an OPD-Scan III aberrometer.
METHODS: Eighty cataract patients who underwent uneventful MfIOL implantation (42 with AcrySof® IQ ReSTOR® SN6AD1 and 38 with AMO Tecnis® ZMB00) were enrolled. At 1 year after surgery, a postoperative visual acuity evaluation included the measurement of uncorrected distance visual acuity, corrected distance visual acuity, distance-corrected near visual acuity, and distance-corrected intermediate visual acuity. OPD-Scan III aberrometer was used to collect the decentration, tilt, and high-order aberration (HOA) data. Significance was tested with Student's t test, Mann-Whitney U test, paired t test, and χ2 test
RESULTS: The average intraocular tilt was lower in the SN6AD1 group than in the ZMB00 group, whereas the average decentration of the two groups did not differ significantly. The mean total ocular HOAs, ocular trefoil, total internal HOAs, and spherical aberrations were significantly lower in the SN6AD1 group than in the ZMB00 group. In both the SN6AD1 and ZMB00 groups, the intraocular tilt was directly proportional to the total ocular HOAs, coma, and spherical aberration. However, there was no significant correlation between decentration and any type of HOA in SN6AD1 group, whereas decentration correlated positively with total ocular HOAs, coma, and spherical aberration in ZMB00 group.
CONCLUSION: Both MfIOLs significantly improve the visual acuity of the patients. However, tilt was lower in the SN6AD1 group than in the ZMB00 group 1 year after surgery, which provide fewer HOAs and better visual quality.

Entities:  

Mesh:

Year:  2018        PMID: 29520045      PMCID: PMC6043556          DOI: 10.1038/s41433-018-0068-5

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  28 in total

1.  Effect of decentration on the optical performance in multifocal intraocular lenses.

Authors:  Mitsutaka Soda; Shigeo Yaguchi
Journal:  Ophthalmologica       Date:  2012-01-03       Impact factor: 3.250

2.  IOL tilt and decentration.

Authors:  Suk Kyue Choi; Jin Hyoung Kim; Doh Lee; Se Hoon Park; Naoyuki Maeda; Ki Jung Ma
Journal:  Ophthalmology       Date:  2010-09       Impact factor: 12.079

3.  Comparison of Ocular Aberrations in Two Hydrophobic and Hydrophilic Intraocular Lenses.

Authors:  Ebrahim Jafarzadehpur; Hassan Hashemi; Tahereh Abdolahinia; Abbas A Yekta; Mehdi Khabazkhoob
Journal:  Eye Contact Lens       Date:  2015-09       Impact factor: 2.018

4.  Intraocular optical quality of phakic intraocular lenses: comparison of angle-supported, iris-fixated, and posterior chamber lenses.

Authors:  Jorge L Alio; Pablo Peña-García; Ketevan Pachkoria; Jorge L Alio; Amr El Aswad
Journal:  Am J Ophthalmol       Date:  2013-07-10       Impact factor: 5.258

5.  Visual outcomes in eyes with a distance-dominant diffractive multifocal intraocular lens with low near addition power.

Authors:  Ken Hayashi; Soichiro Ogawa; Shin-ichi Manabe; Akira Hirata
Journal:  Br J Ophthalmol       Date:  2015-04-14       Impact factor: 4.638

6.  Influence of intraocular lens optical design on high-order aberrations.

Authors:  Futoshi Taketani; Eiichi Yukawa; Toshiaki Yoshii; Yuuko Sugie; Yoshiaki Hara
Journal:  J Cataract Refract Surg       Date:  2005-05       Impact factor: 3.351

7.  Intraocular lens tilt and decentration measured by Scheimpflug camera following manual or femtosecond laser-created continuous circular capsulotomy.

Authors:  Kinga Kránitz; Kata Miháltz; Gábor L Sándor; Agnes Takacs; Michael C Knorz; Zoltán Z Nagy
Journal:  J Refract Surg       Date:  2012-04       Impact factor: 3.573

8.  Comparative study on optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis ® ZMB00 and AcrySof ® IQ ReSTOR ® Multifocal IOL SN6AD1.

Authors:  Mario Augusto Pereira Dias Chaves; Wilson Takashi Hida; Patrick Frenzel Tzeliks; Michelle Rodrigues Gonçalves; Fernando de Bortoli Nogueira; Celso Takashi Nakano; Antonio Francisco Pimenta Motta; André Gustavo Rolim de Araújo; Milton Ruiz Alves
Journal:  Arq Bras Oftalmol       Date:  2016 May-Jun       Impact factor: 0.872

9.  Clinical outcomes after cataract surgery with implantation of the Tecnis ZMB00 multifocal intraocular lens.

Authors:  Wojciech Lubiński; Jolanta Gronkowska-Serafin; Karolina Podborączyńska-Jodko
Journal:  Med Sci Monit       Date:  2014-07-15

10.  Long-term outcomes of ciliary sulcus versus capsular bag fixation of intraocular lenses in children: An ultrasound biomicroscopy study.

Authors:  Yun-E Zhao; Xian-Hui Gong; Xue-Ning Zhu; He-Ming Li; Meng-Jun Tu; Terry G Coursey; Stephen C Pflugfelder; Feng Gu; Ding Chen
Journal:  PLoS One       Date:  2017-03-16       Impact factor: 3.240

View more
  6 in total

1.  Effects of tilt and decentration of Visian Implantable Collamer Lens (ICL V4c) on visual quality: an observational study.

Authors:  Lingling Niu; Zhe Zhang; Huamao Miao; Jing Zhao; Meiyan Li; Ji C He; Peijun Yao; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2022-07-05       Impact factor: 2.086

Review 2.  Tilt and decentration with various intraocular lenses: A narrative review.

Authors:  Xiao-Yong Chen; Yu-Chen Wang; Tian-Yao Zhao; Zi-Zhen Wang; Wei Wang
Journal:  World J Clin Cases       Date:  2022-04-26       Impact factor: 1.534

3.  Intraocular Lens Position and Anterior Chamber Parameters Evaluation After Nd:YAG Laser Posterior Capsulotomy for Posterior Capsular Opacification Using Anterior Segment Swept-Source Optical Coherence Tomography.

Authors:  Marina Delgado João; Jorge Vasco Costa; Tiago Monteiro; Nuno Franqueira; Fernando Faria Correia; Fernando Vaz
Journal:  Clin Ophthalmol       Date:  2022-01-18

4.  Phacoemulsification Combined With Supra-Capsular and Scleral-Fixated Intraocular Lens Implantation in Microspherophakia: A Retrospective Comparative Study.

Authors:  Ze-Xu Chen; Zhen-Nan Zhao; Yang Sun; Wan-Nan Jia; Jia-Lei Zheng; Jia-Hui Chen; Tian-Hui Chen; Li-Na Lan; Yong-Xiang Jiang
Journal:  Front Med (Lausanne)       Date:  2022-04-14

5.  Influence of Angle κ and Higher-Order Aberrations on Visual Quality Employing Two Diffractive Trifocal IOLs.

Authors:  Cecilio Velasco-Barona; Claudia Corredor-Ortega; Alejandra Mendez-Leon; Nadia L Casillas-Chavarín; Daniel Valdepeña-López Velarde; Guadalupe Cervantes-Coste; Daniel Malacara-Hernández; Roberto Gonzalez-Salinas
Journal:  J Ophthalmol       Date:  2019-11-27       Impact factor: 1.909

6.  Determinants of intraocular lens tilt and decentration after cataract surgery.

Authors:  Xiaoxun Gu; Xiaoyun Chen; Guangyao Yang; Wei Wang; Wei Xiao; Guangming Jin; Lanhua Wang; Ye Dai; Xiaoting Ruan; Zhenzhen Liu; Lixia Luo; Yizhi Liu
Journal:  Ann Transl Med       Date:  2020-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.