Literature DB >> 15975463

Influence of intraocular lens optical design on high-order aberrations.

Futoshi Taketani1, Eiichi Yukawa, Toshiaki Yoshii, Yuuko Sugie, Yoshiaki Hara.   

Abstract

PURPOSE: To compare differences in high-order aberrations (HOAs) between 2 intraocular lens (IOL) optical designs.
SETTING: Department of Ophthalmology, Nara Medical University, Nara, Japan.
METHOD: Sixty eyes that had uncomplicated phacoemulsification and IOL implantation were assigned to 1 of 2 groups based on the type of IOL optical design: more posteriorly curved biconvex shape (AcrySof MA30BA, Alcon) (n=30 eyes) or more anteriorly curved biconvex shape (AcrySof MA30AC) (n=30 eyes). All patients had best corrected visual acuity better than 20/25. High-order aberrations were measured using a Hartmann-Shack aberrometer at 4.0 mm and 6.0 mm wavefront aperture diameters.
RESULTS: At 4.0 mm aperture diameters, there were no differences between the 2 groups in HOAs (P>.05, Mann-Whitney U test) in the cornea and the whole eye. At 6.0 mm aperture diameters, MA30AC eyes had a smaller amount of spherical-like aberrations (P=.043) than MA30BA eyes; however, there were no significant differences between the 2 groups in coma-like aberrations and total aberrations in the whole eye (P>.05). At 6.0 mm aperture diameters, there were no differences between the 2 groups HOAs in the cornea. (P>.05).
CONCLUSION: The optical design of the spherical IOL influenced the spherical-like aberrations in the whole eye. This may reduce retinal image quality.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15975463     DOI: 10.1016/j.jcrs.2004.10.064

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Star testing: a novel evaluation of intraocular lens optical quality.

Authors:  L Mitchell; A C B Molteno; T H Bevin; G Sanderson
Journal:  Br J Ophthalmol       Date:  2006-05       Impact factor: 4.638

2.  Comparative study of visual function and ocular aberrations of two different one-piece designed hydrophilic acrylic intraocular lens.

Authors:  Yuxin Zhao; Zhaoxia Wang; Xia Tian; Xuehong Wang; Xining Gao
Journal:  Int Ophthalmol       Date:  2017-05-30       Impact factor: 2.031

3.  Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer.

Authors:  Wenwen He; Xiaodi Qiu; Shaohua Zhang; Yu Du; Yinglei Zhang; Yi Lu; Xiangjia Zhu
Journal:  Eye (Lond)       Date:  2018-03-09       Impact factor: 3.775

4.  Spherical aberration of intraocular lenses.

Authors:  Majid Moshirfar
Journal:  J Ophthalmic Vis Res       Date:  2010-10

5.  Comparing the effect of two different intraocular lenses on optical aberrations in bilaterally operated eyes for cataract.

Authors:  Esra Ayhan Tuzcu; Kuddusi Erkilic; Betul Bulut; Nilufer Ilhan
Journal:  Pak J Med Sci       Date:  2013-07       Impact factor: 1.088

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.