Relation of external surface to internal tumor motion studied with cine CT.

Pai-Chun Melinda Chi1, Peter Balter, Dershan Luo, Radhe Mohan, Tinsu Pan.   

Abstract

The accuracy of delivering gated-radiation therapy to lung tumors using an external respiratory surrogate relies on not only interfractional and intrafractional reproducibility, but also a strong correlation between external motion and internal tumor motion. The purpose of this work was to use the cine images acquired by four-dimensional computed tomography acquisition protocol to study the relation between external surface motion and internal tumor motion. The respiratory phase information of tumor motion and chest wall motion was measured on the cine images using a proposed region-of-interest (ROI) method and compared to measurement of an external respiratory monitoring device. On eight lung patient data sets, the phase shifts were measured between (1) the signal of a real-time positioning-management (RPM) respiratory monitoring device placed in the abdominal region and four surface locations on the chest wall, (2) the RPM signal in the abdominal region and tumor motions, and (3) chest wall surface motions and tumor motions. Respiratory waveforms measured at different surface locations during the same respiratory cycle often varied and had significant phase shifts. Seven of the 8 patients showed the abdominal motion leading chest wall motion. The best correlation (smallest phase shift) was found between the abdominal motion and the superior-inferior (S-I) tumor motion. A wide range of phase shifts was observed between external surface motion and tumor anterior-posterior (A-P)/lateral motion. The result supported the placement of the RPM block in the abdominal region and suggested that during a gated therapy utilizing the RPM system, it is necessary to place the RPM block at the same location as it is during treatment simulation in order to reduce potential errors introduced by the position of the RPM block. Correlations between external motions and lateral/A-P tumor motions were inconclusive due to a combination of patient selection and the limitation of the ROI method.

Entities:  

Mesh:

Year:  2006        PMID: 17022203     DOI: 10.1118/1.2241993

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for radiotherapy treatment planning.

Authors:  David A Zamora; Adam C Riegel; Xiaojun Sun; Peter Balter; George Starkschall; Osama Mawlawi; Tinsu Pan
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

2.  Real-time tumor motion estimation using respiratory surrogate via memory-based learning.

Authors:  Ruijiang Li; John H Lewis; Ross I Berbeco; Lei Xing
Journal:  Phys Med Biol       Date:  2012-07-06       Impact factor: 3.609

3.  Fast internal marker tracking algorithm for onboard MV and kV imaging systems.

Authors:  W Mao; R D Wiersma; L Xing
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  An externally and internally deformable, programmable lung motion phantom.

Authors:  Yam Cheung; Amit Sawant
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

5.  Adaptation of the modified Bouc-Wen model to compensate for hysteresis in respiratory motion for the list-mode binning of cardiac SPECT and PET acquisitions: testing using MRI.

Authors:  Paul K R Dasari; Mohammed Salman Shazeeb; Arda Könik; Clifford Lindsay; Joyeeta M Mukherjee; Karen L Johnson; Michael A King
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

6.  The correlation of tissue motion within the lung: implications on fiducial based treatments.

Authors:  Ryan L Smith; Deshan Yang; Andrew Lee; Martin L Mayse; Dan A Low; Parag J Parikh
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

7.  Inferring positions of tumor and nodes in Stage III lung cancer from multiple anatomical surrogates using four-dimensional computed tomography.

Authors:  Kathleen T Malinowski; Jason R Pantarotto; Suresh Senan; Thomas J McAvoy; Warren D D'Souza
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-03       Impact factor: 7.038

8.  MRI Investigation of the Linkage Between Respiratory Motion of the Heart and Markers on Patient's Abdomen and Chest: Implications for Respiratory Amplitude Binning List-Mode PET and SPECT Studies.

Authors:  Paul Dasari; Karen Johnson; Joyoni Dey; Clifford Lindsay; Mohammed S Shazeeb; Joyeeta Mitra Mukherjee; Shaokuan Zheng; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2014-02-06       Impact factor: 1.679

9.  Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate.

Authors:  Guang Li; Naveen C Arora; Huchen Xie; Holly Ning; Wei Lu; Daniel Low; Deborah Citrin; Aradhana Kaushal; Leor Zach; Kevin Camphausen; Robert W Miller
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

10.  A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging.

Authors:  Weihua Mao; Nadeem Riaz; Louis Lee; Rodney Wiersma; Lei Xing
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.