Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study.

Parag Parekh1, W Richard Green, Walter J Stark, Esen Karamursel Akpek.   

Abstract

PURPOSE: To report the occurrence of subluxation of suture-fixated posterior chamber (PC) intraocular lenses (IOL) and elucidate the mechanisms involved.
DESIGN: Prospective clinicopathologic study. PARTICIPANTS: A single 10-0 Prolene suture explanted from a patient who experienced subluxation of his PC-IOL, 11.5 years after placement. Furthermore, multiple 10-0 Prolene sutures and PC-IOLs used for iris fixation were studied as controls.
METHODS: Scanning electron microscopy (SEM) was used to analyze the surface of the explanted suture. In addition, randomly selected 10-0 Prolene sutures cut with Vannas scissors and cut with the positioning holes of a randomly selected PC-IOL identical to that implanted in the patient's eye were examined as controls. Finally, the positioning holes of several randomly selected, iris-fixated PC-IOLs were studied using SEM with particular attention to surface quality and edge finish. MAIN OUTCOME MEASURES: Presence of any signs of suture degradation, the character of the cut edge of the suture, as well as the characteristics of the positioning holes of the PC-IOLs.
RESULTS: Scanning electron microscopy of the explanted suture revealed sharply cut edges, without significant degradation of the suture, and no intact loop. Scanning electron microscopy of the control suture cut with a PC-IOL demonstrated a similarly cut edge. The positioning holes of the examined PC-IOLs had a sharp edge, and some also had an imperfect finish.
CONCLUSION: We conclude that the surface properties of the positioning holes lead to cutting of the suture, and subsequent subluxation of the PC-IOL.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17270672     DOI: 10.1016/j.ophtha.2006.10.037

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  15 in total

1.  Ocular biocompatibility of nitinol intraocular clips.

Authors:  Jeffrey L Olson; Raul Velez-Montoya; Michael Erlanger
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-25       Impact factor: 4.799

2.  Long-term Outcome of Pars Plana Vitrectomy and Sutured Scleral-Fixated Posterior Chamber Intraocular Lens Implantation or Repositioning.

Authors:  Gregg T Kokame; Ryan T Yanagihara; Jessica G Shantha; Kyle N Kaneko
Journal:  Am J Ophthalmol       Date:  2018-02-07       Impact factor: 5.258

3.  Comparision of surgical outcomes of intraocular lens refixation and intraocular lens exchange with perfluorocarbon liquid and fibrin glue-assisted sutureless scleral fixation.

Authors:  S Y Oh; S J Lee; J M Park
Journal:  Eye (Lond)       Date:  2015-03-20       Impact factor: 3.775

4.  Report of a 10-0 polypropylene suture that did not undergo biodegradation after 13 years in the eye.

Authors:  Michael Coleman; Uri Soiberman; Walter J Stark
Journal:  Digit J Ophthalmol       Date:  2016-08-25

5.  Late dislocation of the capsular bag-intraocular lens-modified capsular tension ring complex after knotless transscleral suturing using 9-0 polypropylene.

Authors:  Natalia S Anisimova; Lisa B Arbisser; Natalya F Shilova; Roman V Kirtaev; Daria A Dibina; Boris E Malyugin
Journal:  Digit J Ophthalmol       Date:  2020-06-26

6.  Glued intraocular lens implantation for eyes with defective capsules: A retrospective analysis of anatomical and functional outcome.

Authors:  Dhivya A Kumar; Athiya Agarwal; Amar Agarwal; Gaurav Prakash; Soosan Jacob
Journal:  Saudi J Ophthalmol       Date:  2011-04-15

7.  A comparative study of transscleral suture-fixated and scleral-fixated intraocular lens implantation.

Authors:  Yu Mizuno; Yosuke Sugimoto
Journal:  Int Ophthalmol       Date:  2018-03-03       Impact factor: 2.031

8.  Glued intraocular lens implantation for eyes with inadequate capsular support: Analysis of the postoperative visual outcome.

Authors:  Sujatha Mohan; Bina John; Mohan Rajan; Harsha Malkani; S V Nagalekshmi; Siddhartha Singh
Journal:  Indian J Ophthalmol       Date:  2017-06       Impact factor: 1.848

9.  Glue-assisted intrascleral fixation of posterior chamber intraocular lens.

Authors:  Priya Narang; Samir Narang
Journal:  Indian J Ophthalmol       Date:  2013-04       Impact factor: 1.848

10.  Evaluation of Sutureless, Glueless, Flapless, Intrascleral Fixated Posterior Chamber Intraocular Lens in Children with Ectopia Lentis.

Authors:  Kannan Nb; Piyush Kohli; Bhanu Pratap Singh Pangtey; Kim Ramasamy
Journal:  J Ophthalmol       Date:  2018-08-29       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.