Intraocular lens implantation in the absence of capsular support: a report by the American Academy of Ophthalmology.

Michael D Wagoner, Terry A Cox, Reginald George Ariyasu, Deborah S Jacobs, Carol L Karp.   

Abstract

OBJECTIVE: This review was conducted to determine the safety and efficacy of open-loop anterior chamber, scleral-sutured posterior chamber, and iris-sutured posterior chamber intraocular lenses (IOLs) in eyes with inadequate capsular support for posterior chamber implantation in the capsular bag or ciliary sulcus. It also attempted to determine whether there is a preferred IOL or fixation site of choice in eyes with inadequate capsular support.
METHODS: A literature search conducted for the years 1980 to 2001 yielded 189 citations related to IOL implantation in the absence of capsular support. An update search, conducted in March 2002, yielded an additional 28 articles. The Anterior Segment Panel members reviewed these abstracts and selected 148 articles of possible clinical relevance for review. Of these, 89 were considered sufficiently clinically relevant for the panel methodologist to review and rate according to the strength of evidence. A level I rating was assigned to properly conducted, well-designed, randomized clinical trials; a level II rating was assigned to well-designed cohort and case-control studies; and a level III rating was assigned to case series. Articles comparing the safety and efficacy of the IOL type and fixation site were further evaluated for the quality of the statistical methods used in the study. Studies with a rating of A or B were considered acceptable, C was borderline, and D and F were considered unacceptable as medical evidence.
RESULTS: Forty-three articles with data concerning outcome of IOL insertion in eyes with inadequate capsular support had an evidence rating of level III or higher and were used in the final review of the safety and efficacy of one or more lens types and/or fixation sites. Seven articles had data about more than one lens type. Six had a statistical method rating of C or higher and were used to evaluate differences in visual outcomes and complication rates between lens types and fixation sites.
CONCLUSIONS: The literature supports the safe and effective use of open-loop anterior chamber, scleral-sutured posterior chamber, and iris-sutured posterior chamber IOLs for the correction of aphakia in eyes without adequate capsular support for placement of a posterior chamber lens in the capsular bag or ciliary sulcus. At this time, there is insufficient evidence to demonstrate the superiority of one lens type or fixation site. Precise determination of small differences in visual outcome or complication rates will require a large prospective, randomized clinical trial.

Entities:  

Mesh:

Year:  2003        PMID: 12689913     DOI: 10.1016/s0161-6420(02)02000-6

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  86 in total

1.  [Secondary intraocular lens implantation using scleral suture fixation].

Authors:  P Szurman; K Gekeler
Journal:  Ophthalmologe       Date:  2014-03       Impact factor: 1.059

2.  Sutureless intrascleral pocket technique of transscleral fixation of intraocular lens in previous vitrectomized eyes.

Authors:  Yong-Wun Cho; In-Young Chung; Ji-Myong Yoo; Seong-Jae Kim
Journal:  Korean J Ophthalmol       Date:  2014-03-14

3.  Late dislocation of an anterior chamber intraocular lens into the vitreous.

Authors:  Vuslat Pelitli Gürlü; Omer Benian
Journal:  Int Ophthalmol       Date:  2007-04-06       Impact factor: 2.031

4.  Scleral fixation of a posterior chamber intraocular lens combined with penetrating keratoplasty in an aphakic patient with microcornea and microphthalmia.

Authors:  He J Li; Konstantinos T Tsaousis; Geoffrey C Tabin
Journal:  BMJ Case Rep       Date:  2016-04-06

Review 5.  Molecular pathogenesis and management strategies of ectopia lentis.

Authors:  A Chandra; D Charteris
Journal:  Eye (Lond)       Date:  2014-01-10       Impact factor: 3.775

6.  Scleral Fixation of Intraocular Lenses with Gore-Tex Suture: Refractive Outcomes and Comparison of Lens Power Formulas.

Authors:  Benjamin W Botsford; Andrew M Williams; Ian P Conner; Joseph N Martel; Andrew W Eller
Journal:  Ophthalmol Retina       Date:  2019-02-19

7.  The novel haptic-twist method for a sutureless double-needle intrascleral haptic fixation technique.

Authors:  Tansu Erakgun; Hamidu Hamisi Gobeka
Journal:  Int Ophthalmol       Date:  2021-05-20       Impact factor: 2.031

8.  27-GAUGE SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENSES WITH HAPTIC FLANGING: Short-Term Clinical Outcomes and a Disinsertion Force Study.

Authors:  Maxwell S Stem; Christianne A Wa; Bozho Todorich; Maria A Woodward; Mark K Walsh; Jeremy D Wolfe
Journal:  Retina       Date:  2019-11       Impact factor: 4.256

Review 9.  Surgical approaches to posterior polar cataract: a review.

Authors:  A R Vasavada; S M Raj; V Vasavada; S Shrivastav
Journal:  Eye (Lond)       Date:  2012-03-23       Impact factor: 3.775

10.  Posterior Chamber Scleral Fixation of Intraocular Lenses in Post-Vitrectomised Aphakic Eyes.

Authors:  Francis Kwasi Obeng; Vipan Kumar Vig; Preetam Singh; Rajbir Singh; Bodhraj Dhawan; Nikhil Sahajpal
Journal:  J Clin Diagn Res       Date:  2017-03-01