Literature DB >> 29460101

Pulse-echo ultrasound method for detection of post-menopausal women with osteoporotic BMD.

J P Karjalainen1, O Riekkinen2, H Kröger3.   

Abstract

We lack effective diagnostics of osteoporosis at the primary health care level. An ultrasound device was used to identify subjects in the osteoporotic range as defined by DXA. A case finding strategy combining ultrasound results with DXA measurements for patients with intermediate ultrasound results is presented.
INTRODUCTION: We lack effective screening and diagnostics of osteoporosis at primary health care. In this study, a pulse-echo ultrasound (US) method is investigated for osteoporosis screening.
METHODS: A total of 1091 Caucasian women (aged 50-80 years) were recruited for the study and measured with US in the tibia and radius. This method measures cortical thickness and provides an estimate of bone mineral density (BMD) and density index (DI). BMD assessment of the hip was available for 988 women. A total of 888 women had one or more risk factors for osteoporosis (OP susp ), and 100 women were classified healthy. Previously determined thresholds for the DI were evaluated for assessment of efficacy of the technique to detect hip BMD at osteoporotic range (T-score at or below - 2.5).
RESULTS: In the OP susp group, the application of thresholds for the DI showed that approximately 32% of the subjects would require an additional DXA measurement. The multi-site ultrasound (US) measurement-based DI showed 93.7% sensitivity and 81.6% specificity, whereas the corresponding values for single-site US measurement-based DI were 84.7 and 82.0%, respectively. The ultrasound measurements showed a high negative predictive value 97.7 to 99.2% in every age decade examined (ages 50-59, 60-69, 70-79 years).
CONCLUSIONS: The study data demonstrate that a strategy of combining ultrasound measurement with added DXA measurements in cases with intermediate ultrasound results (about 30%) can be useful for identifying subjects at risk for a low bone mineral density in the osteoporotic range.

Entities:  

Keywords:  Bone; DXA; Osteoporosis; Screening; Ultrasound

Mesh:

Year:  2018        PMID: 29460101     DOI: 10.1007/s00198-018-4408-x

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  15 in total

1.  Cross-calibration and minimum precision standards for dual-energy X-ray absorptiometry: the 2005 ISCD Official Positions.

Authors:  John A Shepherd; Ying Lu; Kevin Wilson; Thomas Fuerst; Harry Genant; Thomas N Hangartner; Charles Wilson; Didier Hans; Edward S Leib
Journal:  J Clin Densitom       Date:  2006-05-12       Impact factor: 2.617

2.  Prediction of hip osteoporosis by DXA using a novel pulse-echo ultrasound device.

Authors:  J T Schousboe; O Riekkinen; J Karjalainen
Journal:  Osteoporos Int       Date:  2016-08-04       Impact factor: 4.507

3.  Mortality after all major types of osteoporotic fracture in men and women: an observational study.

Authors:  J R Center; T V Nguyen; D Schneider; P N Sambrook; J A Eisman
Journal:  Lancet       Date:  1999-03-13       Impact factor: 79.321

4.  Multi-site bone ultrasound measurements in elderly women with and without previous hip fractures.

Authors:  J P Karjalainen; O Riekkinen; J Töyräs; M Hakulinen; H Kröger; T Rikkonen; K Salovaara; J S Jurvelin
Journal:  Osteoporos Int       Date:  2011-06-09       Impact factor: 4.507

5.  A list of device-specific thresholds for the clinical interpretation of peripheral x-ray absorptiometry examinations.

Authors:  G M Blake; D J Chinn; S A Steel; R Patel; E Panayiotou; J Thorpe; J N Fordham
Journal:  Osteoporos Int       Date:  2005-10-15       Impact factor: 4.507

6.  Mortality and morbidity after hip fractures.

Authors:  G S Keene; M J Parker; G A Pryor
Journal:  BMJ       Date:  1993-11-13

7.  Effect of precision error on T-scores and the diagnostic classification of bone status.

Authors:  Gary M Kiebzak; Kenneth G Faulkner; Wynn Wacker; Ronald Hamdy; Edith Seier; Nelson B Watts
Journal:  J Clin Densitom       Date:  2007-04-23       Impact factor: 2.617

Review 8.  Diagnosis of osteoporosis and assessment of fracture risk.

Authors:  John A Kanis
Journal:  Lancet       Date:  2002-06-01       Impact factor: 79.321

9.  New method for point-of-care osteoporosis screening and diagnostics.

Authors:  J P Karjalainen; O Riekkinen; J Töyräs; J S Jurvelin; H Kröger
Journal:  Osteoporos Int       Date:  2015-11-10       Impact factor: 4.507

10.  Precision error of fan-beam dual X-ray absorptiometry scans at the spine, hip, and forearm.

Authors:  S Henzell; S Dhaliwal; R Pontifex; F Gill; R Price; R Retallack; R Prince
Journal:  J Clin Densitom       Date:  2000       Impact factor: 2.963

View more
  8 in total

Review 1.  Clinical Devices for Bone Assessment.

Authors:  Kay Raum; Pascal Laugier
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

2.  Quantitative Ultrasound (QUS) in the Management of Osteoporosis and Assessment of Fracture Risk: An Update.

Authors:  Didier Hans; Antoine Métrailler; Elena Gonzalez Rodriguez; Olivier Lamy; Enisa Shevroja
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

3.  Associations between radius low-frequency axial ultrasound velocity and bone fragility in elderly men and women.

Authors:  E Biver; J Pepe; A de Sire; T Chevalley; S Ferrari
Journal:  Osteoporos Int       Date:  2018-10-10       Impact factor: 4.507

4.  Application of a Neural Network Classifier to Radiofrequency-Based Osteopenia/Osteoporosis Screening.

Authors:  Johnathan W Adams; Ziming Zhang; Gregory M Noetscher; Ara Nazarian; Sergey N Makarov
Journal:  IEEE J Transl Eng Health Med       Date:  2021-08-30       Impact factor: 3.316

5.  Cost-effectiveness of pulse-echo ultrasonometry in osteoporosis management.

Authors:  Erkki Soini; Ossi Riekkinen; Heikki Kröger; Petri Mankinen; Taru Hallinen; Janne P Karjalainen
Journal:  Clinicoecon Outcomes Res       Date:  2018-05-29

6.  Concept of a Radiofrequency Device for Osteopenia/Osteoporosis Screening.

Authors:  Sergey N Makarov; Gregory M Noetscher; Seth Arum; Robert Rabiner; Ara Nazarian
Journal:  Sci Rep       Date:  2020-02-26       Impact factor: 4.379

7.  Cortical bone thickness of the distal radius predicts the local bone mineral density.

Authors:  Florian Schmidutz; Christoph Schopf; Shuang G Yan; Marc-Daniel Ahrend; Christoph Ihle; Christoph Sprecher
Journal:  Bone Joint Res       Date:  2021-12       Impact factor: 5.853

8.  Trabecular bone score and phalangeal quantitative ultrasound are associated with muscle strength and fracture risk in hemodialysis patients.

Authors:  Antonino Catalano; Agostino Gaudio; Federica Bellone; Mattia Miriam La Fauci; Anastasia Xourafa; Guido Gembillo; Giorgio Basile; Giuseppe Natale; Giovanni Squadrito; Francesco Corica; Nunziata Morabito; Domenico Santoro
Journal:  Front Endocrinol (Lausanne)       Date:  2022-09-07       Impact factor: 6.055

  8 in total