Literature DB >> 7576095

High dose rate (HDR) brachytherapy technique: for carcinoma of uterine cervix using Nucletron applicators.

M T Nair1, M C Cheng, A Barker, B S Rouse.   

Abstract

This study describes our existing treatment method for high dose rate (HDR) brachytherapy of carcinoma of uterine cervix using Nucletron applicators. Based on our clinical experience with low dose rate (LDR) brachytherapy since 1986, we deliver 40-45Gy by external and 30Gy by internal radiation therapy. The change in regimen using HDR brachytherapy is that internal radiation dose is given in 5 fractions at weekly intervals following external radiotherapy. We have analyzed the dosimetry of 20 patients; total of 100 treatments done at our center using ring-tandem (R-T) and ovoid-tandem (O-T) applicator combinations. Since O-T applicator has more flexibility of using desired tandem length and reduced rectum and bladder dose due to internal shielding inside the ovoids, we have made the transition from R-T to O-T combination of applicator. The dose volume histogram of the isodose curve indicates that there is an increase in isodose volume with the O-T applicator by as much as 1.5 times as compared to R-T applicator. In majority of the treatments, rectum and bladder doses are less than 70% of target dose, however in very few treatments, the bladder dose has increased to more than the target dose, in which case, the applicators were reseated and added more packing or reduced the dose per fraction, for better tolerance of late responding normal tissues. All our dose calculations are checked with an independent calculation method and agreement was obtained with in 5-7% discrepancy.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7576095     DOI: 10.1016/0958-3947(95)00019-s

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  3 in total

1.  Short-term clinical outcome and dosimetric comparison of tandem and ring versus tandem and ovoids intracavitary applicators.

Authors:  John K Ma; Waleed F Mourad; Robert Allbright; Satyaseelan Packianathan; Leslie M Harrell; Edmund Chinchar; Alex Nguyen; Srinivasan Vijayakumar
Journal:  J Contemp Brachytherapy       Date:  2015-05-28

Review 2.  Evolution of Brachytherapy Applicators for the Treatment of Cervical Cancer.

Authors:  Ankur Mourya; Lalit Mohan Aggarwal; Sunil Choudhary
Journal:  J Med Phys       Date:  2021-12-31

3.  Dosimetric evaluation of image based brachytherapy using tandem ovoid and tandem ring applicators.

Authors:  Ramya Rangarajan
Journal:  Rep Pract Oncol Radiother       Date:  2018-01-12