Literature DB >> 29340986

Comparison of maximal Rubidium-82 activities for myocardial blood flow quantification between digital and conventional PET systems.

Joris D van Dijk1, Pieter L Jager2, Jochen A C van Osch3, Maryam Khodaverdi4, Jorn A van Dalen3.   

Abstract

BACKGROUND: PET-based myocardial blood flow (MBF) quantification can be inaccurate when using high tracer activities. Our aim was to derive the maximal Rubidium-82 activity for MBF assessment using a new digital PET system and compare the results with conventional analog systems.
METHODS: 1.8 GBq Rubidium-82 was injected into the cardiac insert of an anthropomorphic torso phantom. Data were acquired for 10 min using an Ingenuity TF (Philips Healthcare), Discovery 690 (D690, GE Healthcare), and digital PET prototype system (Philips Healthcare). The dynamic ranges, defined as the maximal measured activity in the reconstructed images deviating < 10% from the true present activity, were determined in all scans.
RESULTS: The dynamic ranges were 312 MBq for Ingenuity TF, 650 MBq for D690, and 654 MBq for digital PET prototype.
CONCLUSIONS: The maximal Rb-82 activity for MBF assessment using digital PET prototype is higher than that for its analog counterpart (Ingenuity TF), but seems comparable to the D690.

Entities:  

Keywords:  Digital PET; cardiac positron emission tomography; direct photon counting; dynamic range; rubidium-82

Year:  2018        PMID: 29340986     DOI: 10.1007/s12350-017-1156-9

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  10 in total

Review 1.  Recent Advances and Future Progress in PET Instrumentation.

Authors:  Piotr J Slomka; Tinsu Pan; Guido Germano
Journal:  Semin Nucl Med       Date:  2016-01       Impact factor: 4.446

2.  Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions.

Authors:  Jeffrey A Kolthammer; Kuan-Hao Su; Anu Grover; Manoj Narayanan; David W Jordan; Raymond F Muzic
Journal:  Phys Med Biol       Date:  2014-06-23       Impact factor: 3.609

3.  Minimizing rubidium-82 tracer activity for relative PET myocardial perfusion imaging.

Authors:  Eline D Huizing; Joris D van Dijk; Jorn A van Dalen; Jorik R Timmer; Hester Arkies; Cees H Slump; Pieter L Jager
Journal:  Nucl Med Commun       Date:  2017-08       Impact factor: 1.690

4.  Variation in Maximum Counting Rates During Myocardial Blood Flow Quantification Using 82Rb PET.

Authors:  Joris D van Dijk; Pieter L Jager; Jochen A C van Osch; Jorn A van Dalen
Journal:  J Nucl Med       Date:  2017-01-19       Impact factor: 10.057

5.  Reply: Variation in Maximum Counting Rates During Myocardial Blood Flow Quantification Using 82Rb PET.

Authors:  Jennifer M Renaud; Jonathan B Moody; Robert A deKemp
Journal:  J Nucl Med       Date:  2017-01-26       Impact factor: 10.057

6.  Characterization of 3-Dimensional PET Systems for Accurate Quantification of Myocardial Blood Flow.

Authors:  Jennifer M Renaud; Kathy Yip; Jean Guimond; Mikaël Trottier; Philippe Pibarot; Eric Turcotte; Conor Maguire; Lucille Lalonde; Karen Gulenchyn; Troy Farncombe; Gerald Wisenberg; Jonathan Moody; Benjamin Lee; Steven C Port; Timothy G Turkington; Rob S Beanlands; Robert A deKemp
Journal:  J Nucl Med       Date:  2016-08-18       Impact factor: 10.057

7.  Quantification of coronary flow reserve in patients with ischaemic and non-ischaemic cardiomyopathy and its association with clinical outcomes.

Authors:  Maulik D Majmudar; Venkatesh L Murthy; Ravi V Shah; Swathy Kolli; Negareh Mousavi; Courtney R Foster; Jon Hainer; Ron Blankstein; Sharmila Dorbala; Arkadiusz Sitek; Lynne W Stevenson; Mandeep R Mehra; Marcelo F Di Carli
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-02-25       Impact factor: 6.875

8.  Image Quality and Diagnostic Performance of a Digital PET Prototype in Patients with Oncologic Diseases: Initial Experience and Comparison with Analog PET.

Authors:  Nghi C Nguyen; Jose L Vercher-Conejero; Abdus Sattar; Michael A Miller; Piotr J Maniawski; David W Jordan; Raymond F Muzic; Kuan-Hao Su; James K O'Donnell; Peter F Faulhaber
Journal:  J Nucl Med       Date:  2015-07-09       Impact factor: 10.057

Review 9.  Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease?: A systematic review and meta-analysis.

Authors:  Brian A Mc Ardle; Taylor F Dowsley; Robert A deKemp; George A Wells; Rob S Beanlands
Journal:  J Am Coll Cardiol       Date:  2012-10-03       Impact factor: 24.094

Review 10.  Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow?

Authors:  Robert A deKemp; Keiichiro Yoshinaga; Rob S B Beanlands
Journal:  J Nucl Cardiol       Date:  2007 May-Jun       Impact factor: 5.952

  10 in total
  3 in total

1.  Effect of temporal sampling protocols on myocardial blood flow measurements using Rubidium-82 PET.

Authors:  S S Koenders; J D van Dijk; P L Jager; M Mouden; A G Tegelaar; C H Slump; J A van Dalen
Journal:  J Nucl Cardiol       Date:  2021-03-02       Impact factor: 3.872

2.  Assessment of a digital and an analog PET/CT system for accurate myocardial perfusion imaging with a flow phantom.

Authors:  Reetta Siekkinen; Anna K Kirjavainen; Kalle Koskensalo; Nadia A S Smith; Andrew Fenwick; Virva Saunavaara; Tuula Tolvanen; Hidehiro Iida; Antti Saraste; Mika Teräs; Jarmo Teuho
Journal:  J Nucl Cardiol       Date:  2021-05-04       Impact factor: 3.872

3.  Value of SiPM PET in myocardial perfusion imaging using Rubidium-82.

Authors:  S S Koenders; J A van Dalen; P L Jager; S Knollema; J R Timmer; M Mouden; C H Slump; J D van Dijk
Journal:  J Nucl Cardiol       Date:  2020-05-14       Impact factor: 5.952

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.