Literature DB >> 29296337

On a single isocenter volumetric modulated arc therapy SRS planning technique for multiple brain metastases.

Nicholas Hardcastle1,2,3, Wolfgang A Tome1,3,4.   

Abstract

Volumetric modulated arc therapy (VMAT) is a new technique for efficient delivery of intensity modulated dose distributions. This study investigates a single isocenter VMAT technique to treat multiple brain metastases to 15 - 24 Gy. The Pinnacle3 SmartArc VMAT optimization plugin was used for all VMAT plans. A non-coplanar arc technique using five 100° arcs and one isocenter was compared with a conformal arc technique which used anywhere from 5 to 9 arcs with at least one isocenter per target. Comparison was done using the Conformality Number (CN), Prescription Isodose to Target Volume (PITV), Homogeneity Index (HI), Conformity-Gradient Index (CGI) as well as the 12 Gy isodose volume in the normal brain from which the risk of symptomatic necrosis (S-NEC) was calculated. The VMAT technique resulted in plans with a maximum delivery of 15 minutes, regardless of the number of targets. The VMAT technique provided superior conformity for large targets but for small targets the conformal arc technique resulted in superior conformity. For all targets, the conformal arc technique resulted in superior dose fall off outside of the target. The VMAT technique resulted in an increase in the 12 Gy volume over the conformal arc technique, with an accompanying increase in risk of S-NEC. While the 12 Gy volume was still within an acceptable clinical range, 4 out 20 patients showed a significant increase (15-20%) in absolute risk of S-NEC. Thus the VMAT technique resulted in clinically acceptable plans with vast reductions in treatment time.

Entities:  

Keywords:  VMAT; intracranial; multiple metastases; single isocenter; smartArc

Year:  2012        PMID: 29296337      PMCID: PMC5658858     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  12 in total

1.  A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note.

Authors:  I Paddick
Journal:  J Neurosurg       Date:  2000-12       Impact factor: 5.115

2.  A simple and reliable index for scoring rival stereotactic radiosurgery plans.

Authors:  Thomas H Wagner; Francis J Bova; William A Friedman; John M Buatti; Lionel G Bouchet; Sanford L Meeks
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-11-15       Impact factor: 7.038

3.  Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs.

Authors:  Chantal Audet; Brett A Poffenbarger; Pauling Chang; Paul S Jackson; Robert E Lundahl; Stephen I Ryu; Gordon R Ray
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

4.  A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases.

Authors:  Jun Kang; Eric C Ford; Koren Smith; John Wong; Todd R McNutt
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

5.  A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate.

Authors:  A van't Riet; A C Mak; M A Moerland; L H Elders; W van der Zee
Journal:  Int J Radiat Oncol Biol Phys       Date:  1997-02-01       Impact factor: 7.038

6.  Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines.

Authors:  E Shaw; R Kline; M Gillin; L Souhami; A Hirschfeld; R Dinapoli; L Martin
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-12-01       Impact factor: 7.038

7.  A comparison of helical tomotherapy to circular collimator-based linear-accelerator radiosurgery for the treatment of brain metastases.

Authors:  Emilie T Soisson; Minesh P Mehta; Wolfgang A Tomé
Journal:  Am J Clin Oncol       Date:  2011-08       Impact factor: 2.339

8.  12 Gy gamma knife radiosurgical volume is a predictor for radiation necrosis in non-AVM intracranial tumors.

Authors:  Timothy Korytko; Tomas Radivoyevitch; Valdir Colussi; Barry W Wessels; Kunjan Pillai; Robert J Maciunas; Douglas B Einstein
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-10-14       Impact factor: 7.038

9.  Intensity modulation with photons for benign intracranial tumours: a planning comparison of volumetric single arc, helical arc and fixed gantry techniques.

Authors:  Antonella Fogliata; Alessandro Clivio; Giorgia Nicolini; Eugenio Vanetti; Luca Cozzi
Journal:  Radiother Oncol       Date:  2008-08-28       Impact factor: 6.280

10.  Single fraction radiosurgery using Rapid Arc for treatment of intracranial targets.

Authors:  Hendrik A Wolff; Daniela M Wagner; Hans Christiansen; Clemens F Hess; Hilke Vorwerk
Journal:  Radiat Oncol       Date:  2010-09-13       Impact factor: 3.481

View more
  11 in total

1.  Interinstitutional Plan Quality Assessment of 2 Linac-Based, Single-Isocenter, Multiple Metastasis Radiosurgery Techniques.

Authors:  Haisong Liu; Evan M Thomas; Jun Li; Yan Yu; David Andrews; James M Markert; John B Fiveash; Wenyin Shi; Richard A Popple
Journal:  Adv Radiat Oncol       Date:  2019-12-02

2.  SBRT treatment of multiple extracranial oligometastases using a single isocenter with distinct optimizations.

Authors:  Michael Trager; Joseph Salama; Fang-Fang Yin; Justus Adamson
Journal:  J Radiosurg SBRT       Date:  2017

3.  Spatial variations of multiple off-axial targets for a single isocenter SRS treatment in Novalis Tx linac system.

Authors:  Sangroh Kim; Tzu-Chi Tseng; Andrew Morrow
Journal:  J Radiosurg SBRT       Date:  2015

4.  Plan Quality and Treatment Efficiency for Radiosurgery to Multiple Brain Metastases: Non-Coplanar RapidArc vs. Gamma Knife.

Authors:  Haisong Liu; David W Andrews; James J Evans; Maria Werner-Wasik; Yan Yu; Adam Paul Dicker; Wenyin Shi
Journal:  Front Oncol       Date:  2016-02-11       Impact factor: 6.244

5.  Single isocenter treatment planning techniques for stereotactic radiosurgery of multiple cranial metastases.

Authors:  Christian Velten; Rafi Kabarriti; Madhur Garg; Wolfgang A Tomé
Journal:  Phys Imaging Radiat Oncol       Date:  2021-01-20

6.  Comparison of dosimetric impact of intra-fractional setup discrepancy between multiple- and single-isocenter approaches in linac-based stereotactic radiotherapy of multiple brain metastases.

Authors:  Sylvia S W Tsui; Vincent W C Wu; Jerry S C Cheung
Journal:  J Appl Clin Med Phys       Date:  2021-12-20       Impact factor: 2.102

7.  Dosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcsDosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcs.

Authors:  Haisong Liu; Jun Li; Evangelos Pappas; David Andrews; James Evans; Maria Werner-Wasik; Yan Yu; Adam Dicker; Wenyin Shi
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

8.  Dosimetric effect of rotational setup errors in stereotactic radiosurgery with HyperArc for single and multiple brain metastases.

Authors:  Tomohiro Sagawa; Shingo Ohira; Yoshihiro Ueda; Yuichi Akino; Hirokazu Mizuno; Masao Matsumoto; Masayoshi Miyazaki; Masahiko Koizumi; Teruki Teshima
Journal:  J Appl Clin Med Phys       Date:  2019-09-11       Impact factor: 2.102

9.  Improving efficiency in the radiation management of multiple brain metastases using a knowledge-based planning solution for single-isocentre volumetric modulated arc therapy (VMAT) technique.

Authors:  James O'Toole; Maddison Picton; Mario Perez; Michael Back; Dasantha Jayamanne; Andrew Le; Kenny Wu; Chris Brown; John Atyeo
Journal:  J Med Radiat Sci       Date:  2021-07-26

10.  The use of collimator angle optimization and jaw tracking for VMAT-based single-isocenter multiple-target stereotactic radiosurgery for up to six targets in the Varian Eclipse treatment planning system.

Authors:  Lauren M M Pudsey; Dean Cutajar; Alex Wallace; Anastasia Saba; Laurel Schmidt; Andrej Bece; Catherine Clark; Yoshiya Yamada; Giordano Biasi; Anatoly Rosenfeld; Joel Poder
Journal:  J Appl Clin Med Phys       Date:  2021-07-19       Impact factor: 2.102

View more