Literature DB >> 19690623

A Multi-Threshold Sampling Method for TOF PET Signal Processing.

H Kim1, C M Kao, Q Xie, C T Chen, L Zhou, F Tang, H Frisch, W W Moses, W S Choong.   

Abstract

As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multi-threshold sampling method to generate samples of a PET event waveform with respect to a few user-defined amplitudes. In this sampling scheme, one can extract both the energy and timing information for an event. In this paper, we report our prototype implementation of this sampling method and the performance results obtained with this prototype. The prototype consists of two multi-threshold discriminator boards and a time-to-digital converter (TDC) board. Each of the multi-threshold discriminator boards takes one input and provides up to 8 threshold levels, which can be defined by users, for sampling the input signal. The TDC board employs the CERN HPTDC chip that determines the digitized times of the leading and falling edges of the discriminator output pulses. We connect our prototype electronics to the outputs of two Hamamatsu R9800 photomultiplier tubes (PMTs) that are individually coupled to a 6.25×6.25×25mm(3) LSO crystal. By analyzing waveform samples generated by using four thresholds, we obtain a coincidence timing resolution of about 340 ps and an ∼18% energy resolution at 511 keV. We are also able to estimate the decay-time constant from the resulting samples and obtain a mean value of 44ns with an ∼9 ns FWHM. In comparison, using digitized waveforms obtained at a 20 GSps sampling rate for the same LSO/PMT modules we obtain ∼300 ps coincidence timing resolution, ∼14% energy resolution at 511 keV, and ∼5 ns FWHM for the estimated decay-time constant. Details of the results on the timing and energy resolutions by using the multi-threshold method indicate that it is a promising approach for implementing digital PET data acquisition.

Entities:  

Year:  2009        PMID: 19690623      PMCID: PMC2727689          DOI: 10.1016/j.nima.2009.01.100

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  4 in total

1.  Modularized compact positron emission tomography detector for rapid system development.

Authors:  Daoming Xi; Xiang Liu; Chen Zeng; Wei Liu; Yanzhao Li; Yuexuan Hua; Xiongze Mei; Heejong Kim; Peng Xiao; Chien-Min Kao; Qingguo Xie
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-20

2.  A Time-Walk Correction Method for PET Detectors Based on Leading Edge Discriminators.

Authors:  Junwei Du; Jeffrey P Schmall; Martin S Judenhofer; Kun Di; Yongfeng Yang; Simon R Cherry
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2017-07-13

3.  Investigation of a Model-based Time-over-threshold Technique for Phoswich Crystal Discrimination.

Authors:  Haithem Bouziri; Catherine M Pepin; Konin Koua; Maher Benhouria; Caroline Paulin; Jinsong Ouyang; Marc Normandin; Jean-François Pratte; Georges El Fakhri; Roger Lecomte; Réjean Fontaine
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-05-04

4.  New Digital Plug and Imaging Sensor for a Proton Therapy Monitoring System Based on Positron Emission Tomography.

Authors:  Nicola D'Ascenzo; Min Gao; Emanuele Antonecchia; Paolo Gnudi; Hsien-Hsin Chen; Fang-Hsin Chen; Ji-Hong Hong; Ing-Tsung Hsiao; Tzu-Chen Yen; Weidong Wang; Daoming Xi; Bo Zhang; Qingguo Xie
Journal:  Sensors (Basel)       Date:  2018-09-08       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.