| Literature DB >> 29246189 |
Santiago Esteban1,2, Ricardo Ricci3,4, Sergio Terrasa3,5,6, Karin Kopitowski3,7.
Abstract
BACKGROUND: In recent years, there has been growing concern about the overuse of colonoscopy (CC). Our objective was to evaluate the incidence rate and cumulative probability of having a potentially inadequate CC (PI-CC, e.g. a CC that was performed earlier that recommended) and the association between the report of a hyperplastic polyp in the baseline CC report and the probability of having a PI-CC.Entities:
Keywords: Colonoscopy; Colorectal cancer; Over screening
Mesh:
Year: 2017 PMID: 29246189 PMCID: PMC5732490 DOI: 10.1186/s12876-017-0722-6
Source DB: PubMed Journal: BMC Gastroenterol ISSN: 1471-230X Impact factor: 3.067
Fig. 1Patient flow chart
Baseline characteristics of patients included in the cohort
| No Potentially inadequate colonoscopy | Potentially inadequate colonoscopy |
| |
|---|---|---|---|
| N (total = 389) | 299 | 90 | |
| Age (median [IQR]) | 63.00 [58.00, 70.00] | 62.00 [58.25, 65.00] | 0.06 |
| Age categories (%) | 0.002 | ||
| 50–54 | 33 (11.0) | 11 (12.2) | |
| 55–59 | 71 (23.7) | 19 (21.1) | |
| 60–64 | 62 (20.7) | 33 (36.7) | |
| 65–69 | 56 (18.7) | 19 (21.1) | |
| 70–74 | 77 (25.8) | 8 (8.9) | |
| Female (%) | 200 (66.9) | 53 (58.9) | 0.20 |
| No. comorbidities (%) | 0.87 | ||
| 0 | 83 (27.8) | 28 (31.1) | |
| 1 | 100 (33.4) | 27 (30.0) | |
| 2 | 51 (17.1) | 18 (20) | |
| 3 | 40 (13.4) | 11 (12.2) | |
| >3 | 25 (8.4) | 6 (6.4) | |
| Baseline motive for Colonoscopy: Screening (%) | 71 (23.7) | 26 (28.9) | 0.39 |
| Reported polyp (%) | 42 (14) | 22 (24.4) | 0.03 |
| Polypectomy (%) | 35 (11.7) | 20 (22.2) | 0.02 |
| Mucosectomy (%) | 1 (0.3) | 3 (3.3) | 0.06 |
| Biopsy (%) | 44 (14.4) | 19 (21.1) | 0.17 |
| Anemia (%) | 46 (15.4) | 3 (3.3) | 0.005 |
| Weight loss (%) | 3 (1.0) | 0 (0.0) | 0.79 |
Fig. 2Cumulative probability of a potentially inadequate colonoscopy
Fig. 3Cumulative probability of a PI-VCC by reported lesion in baseline VCC
Crude and adjusted HR for having a PI-CC performed
| Crude Hazard Ratio | |||
|---|---|---|---|
| HR | 95% CI |
| |
| Polyp reported | 1.663 | 1.03, 2.69 | 0.04 |
| Adjusted Hazard Ratio | |||
| Polyp reported | 1.67 | 1.02, 2.73 | 0.04 |
| Sex: Female | 0.81 | 0.53, 1.25 | 0.34 |
| Age at baseline: linear term | 0.979 | 0.945, 1.017 | 0.29 |
| Age at baseline: non-linear terms | – | – | 0.001 |
| Motive for Colonoscopy: Screening | 1.112 | 0.704, 1.758 | 0.65 |
| Anemia | 0.281 | 0.09, 0.895 | 0.03 |
| Modified Elixhauser Comorbidity index | 1.026 | 0.88, 1.2 | 0.74 |