| Literature DB >> 29216865 |
Yueh-Chang Lee1, Jen-Hung Wang2,3, Cheng-Jen Chiu4,5.
Abstract
BACKGROUND: Several studies reported the efficacy of orthokeratology for myopia control. Somehow, there is limited publication with follow-up longer than 3 years. This study aims to research whether overnight orthokeratology influences the progression rate of the manifest refractive error of myopic children in a longer follow-up period (up to 12 years). And if changes in progression rate are found, to investigate the relationship between refractive changes and different baseline factors, including refraction error, wearing age and lens replacement frequency. In addition, this study collects long-term safety profile of overnight orthokeratology.Entities:
Keywords: Contact lenses; Myopia; Myopia control; Optical intervention; Orthokeratology
Mesh:
Year: 2017 PMID: 29216865 PMCID: PMC5721542 DOI: 10.1186/s12886-017-0639-4
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Comparison of Demographics between OK Group and Control Group
| Variable | OK Group | Control Group |
| Total |
|---|---|---|---|---|
| Number of eyes | 131 | 72 | 203 | |
| Wearing Age | 11.65 ± 0.24 | 11.83 ± 0.26 | 0.628 | 11.72 ± 0.18 |
| Gender | 0.058 | |||
| Male | 61 (46.6%) | 44 (61.1%) | 105 (51.7%) | |
| Female | 70 (53.4%) | 28 (38.9%) | 98 (48.3%) | |
| Sphere refraction (D) | −3.82 ± 0.14 | −3.48 ± 0.20 | 0.167 | −3.70 ± 0.12 |
| Cylinder refraction (D) | −0.56 ± 0.07 | −0.52 ± 0.08 | 0.683 | −0.55 ± 0.05 |
| M | −3.54 ± 0.14 | −3.22 ± 0.19 | −3.43 ± 0.12 | |
| J0 | −0.26 ± 0.03 | −0.25 ± 0.04 | −0.26 ± 0.03 | |
| J45 | −0.03 ± 0.01 | 0.03 ± 0.01 | −0.01 ± 0.01 | |
| Follow-up Time (years) | 6.20 ± 0.21 | 6.53 ± 0.17 | 0.291 | 6.32 ± 0.15 |
Data are presented as n(%) or mean ± standard error of the mean
*p-value < 0.05 was considered statistically significant after test
D, diopters; M, the spherical equivalent; J0, the astigmatism power vector associated with a horizontally oriented axis; J45, the astigmatism power vector associated with an obliquely oriented axis in the 45° meridian
Fig. 1Trend of refractive error change. The trend of refractive error change during year 0 to year 2 for OK and control groups were 0.17 ± 0.02 D and 0.52 ± 0.03 D (mean ± SE), respectfully. The trend of refractive error change during year 2 to year 4 for OK and control groups were 0.23 ± 0.03 D and 0.50 ± 0.03 D (mean ± SE), respectfully. The trend of refractive error change during year 4 to year 6 for OK and control groups were 0.28 ± 0.03 D and 0.47 ± 0.03 D (mean ± SE), respectfully. The trend of refractive error change during year 6 to year 8 for OK and control groups were 0.32 ± 0.05 D and 0.37 ± 0.04 D (mean ± SE), respectfully. Asterisk (*) denotes statistically significant difference between OK and control groups
Baseline Characteristics and Treatment Parameters of 66 OK subjects
| Variable | n(%) or mean ± S.E. |
|---|---|
| Number of eyes | 131 |
| Gender | |
| Male | 61(46.6%) |
| Female | 70 (53.4%) |
| Age | 11.65 ± 0.24 |
| < =10 years-old | 39 (29.8%) |
| > 10 years-old | 92 (70.2%) |
| Ocular sphere refraction (D) | −3.82 ± 0.14 |
| < −5D | 91 (69.5%) |
| > = − 5D | 40 (30.5%) |
| Ocular cylinder refraction (D) | −0.56 ± 0.07 |
| < −1.5D | 117 (89.3%) |
| > =1.5D | 14 (10.7%) |
| M | −3.54 ± 0.14 |
| J0 | −0.26 ± 0.03 |
| J45 | −0.03 ± 0.01 |
| Keratometry value (D) | 43.64 ± 0.11 |
| Follow-up time (years) | 6.20 ± 0.21 |
| Regular lens replacement | |
| No | 23 (17.6%) |
| Yes | 108 (82.4%) |
Data are presented as n(%) or mean ± standard error of the mean
D, diopters; M, the spherical equivalent; J0, the astigmatism power vector associated with a horizontally oriented axis; J45, the astigmatism power vector associated with an obliquely oriented axis in the 45° meridian
The effect of orthokeratology corrections at different periods over 12 years follow-up
| Item | 1st to 2nd year | 3rd to 4th year | 5th to 6th year | 7th to 8th year | 9th to 10th year | 11th to 12th year |
|---|---|---|---|---|---|---|
| Number of eyes | 131 | 129 | 95 | 58 | 18 | 8 |
| Change of refractive error | 0.17 ± 0.02 | 0.23 ± 0.03 | 0.28 ± 0.03 | 0.32 ± 0.05 | 0.23 ± 0.07 | 0.06 ± 0.04 |
| Change of corneal curvature | −1.72 ± 0.08 | −1.57 ± 0.09 | −1.45 ± 0.11 | −1.45 ± 0.16 | −1.18 ± 0.30 | −2.14 ± 0.69 |
Data are presented as n or mean ± standard error of the mean
GEE Model predicting change of refractive error over 8 years follow-up. (n = 131)
| Predictor | β | S.E. | Z |
|
|---|---|---|---|---|
| A | ||||
| Intercept | −0.039 | 0.105 | −0.37 | 0.711 |
| Wearing Age(>10 y/o vs. <=10 y/o) | 0.063 | 0.051 | 1.24 | 0.215 |
| Stable Change(Yes vs. No) | −0.014 | 0.010 | −1.43 | 0.151 |
| Initial D(> = −5D vs. <−5D) | −0.012 | 0.054 | −0.22 | 0.829 |
| Initial A(> = −1.5D vs. <−1.5D) | 0.181 | 0.070 | 2.60 | 0.009* |
| B | ||||
| Intercept | −0.039 | 0.105 | −0.37 | 0.711 |
| Wearing Age (>10 y/o vs. <=10 y/o) | 0.063 | 0.051 | 1.24 | 0.215 |
| Stable Change (Yes vs. No) | −0.014 | 0.010 | −1.43 | 0.151 |
| M | −0.012 | 0.010 | −1.14 | 0.255 |
| J0 | −0.189 | 0.051 | −3.72 | <0.001* |
| J45 | −0.076 | 0.099 | −0.77 | 0.444 |
Abbreviation: GEE, generalized estimating equations
*p-value < 0.05 was considered statistically significant after test
D, diopters; M, the spherical equivalent; J0, the astigmatism power vector associated with a horizontally oriented axis; J45, the astigmatism power vector associated with an obliquely oriented axis in the 45° meridian
GEE Model predicting change of refractive error over 12 years follow-up. (n = 131)
| Predictor | β | S.E. | Z |
|
|---|---|---|---|---|
| a | ||||
| Intercept | −0.010 | 0.091 | −0.11 | 0.916 |
| Wearing Age(>10 y/o vs. <=10 y/o) | 0.058 | 0.050 | 1.17 | 0.240 |
| Stable Change(Yes vs. No) | −0.013 | 0.010 | −1.38 | 0.167 |
| Initial D(> = −5D vs. <−5D) | −0.007 | 0.053 | −0.13 | 0.898 |
| Initial A(> = −1.5D vs. <−1.5D) | 0.153 | 0.056 | 2.75 | 0.006* |
| b | ||||
| Intercept | −0.010 | 0.091 | −0.11 | 0.916 |
| Wearing Age (>10 y/o vs. <=10 y/o) | 0.058 | 0.050 | 1.17 | 0.240 |
| Stable Change (Yes vs. No) | −0.013 | 0.010 | −1.38 | 0.167 |
| M | −0.013 | 0.010 | −1.38 | 0.169 |
| J0 | −0.182 | 0.045 | −4.02 | <0.001* |
| J45 | −0.045 | 0.102 | −0.44 | 0.659 |
Abbreviation: GEE, generalized estimating equations
*p-value < 0.05 was considered statistically significant after test
D, diopters; M, the spherical equivalent; J0, the astigmatism power vector associated with a horizontally oriented axis; J45, the astigmatism power vector associated with an obliquely oriented axis in the 45° meridian
Fig. 2Trend of refractive error change (a) By different wearing age groups (b) By initial myopic refraction groups (c) By initial astigmatism groups and (d) By stable lens change groups. Asterisk (*) denotes statistically significant difference between OK and control groups