Literature DB >> 2920155

Accuracy of routine intraocular lens power calculation in a district general hospital.

P T Gregory1, R M Esbester, D L Boase.   

Abstract

To assess the accuracy of routine preoperative biometry we reviewed all cases of extracapsular cataract extraction with posterior chamber implant performed at Queen Alexandra Hospital in 1985. Of 471 eyes included in the survey 67.9% were within 1.0 D of the expected refraction and 90.7% within 2.0 D. Factors influencing accuracy are discussed. The necessity of routine preoperative biometry is emphasised.

Entities:  

Mesh:

Year:  1989        PMID: 2920155      PMCID: PMC1041644          DOI: 10.1136/bjo.73.1.57

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  22 in total

1.  Posterior chamber intraocular lens power calculation in 441 cases.

Authors:  W F Maloney; R P Kratz; T R Mazzocco; B Davidson
Journal:  J Am Intraocul Implant Soc       Date:  1979-10

2.  Control of astigmatism after surgery and trauma.

Authors:  M J Roper-Hall
Journal:  Br J Ophthalmol       Date:  1982-09       Impact factor: 4.638

3.  The computer calculation of intraocular lens power. A clinical study.

Authors:  J S Hillman
Journal:  Trans Ophthalmol Soc U K       Date:  1980-04

4.  Intraocular lens optical quality: update 1979.

Authors:  R J Olson
Journal:  J Am Intraocul Implant Soc       Date:  1980-01

5.  Accuracy of ultrasound intraocular lens calculation.

Authors:  K J Hoffer
Journal:  Arch Ophthalmol       Date:  1981-10

6.  Posterior chamber implant power calculation: regression formulas.

Authors:  J Retzlaff
Journal:  J Am Intraocul Implant Soc       Date:  1980-07

7.  Improvement of intraocular lens power calculation using empirical data.

Authors:  D R Sanders; M C Kraff
Journal:  J Am Intraocul Implant Soc       Date:  1980-07

8.  Biometry of 7,500 cataractous eyes.

Authors:  K J Hoffer
Journal:  Am J Ophthalmol       Date:  1980-09       Impact factor: 5.258

9.  Clinical evaluation of the DBR A-scan unit.

Authors:  G E Johns
Journal:  J Am Intraocul Implant Soc       Date:  1979-07

10.  The optical quality of currently manufactured intraocular lenses.

Authors:  R J Olson; H Kolodner; H E Kaufman
Journal:  Am J Ophthalmol       Date:  1979-09       Impact factor: 5.258

View more
  3 in total

1.  Calculation of the power of anterior chamber implants.

Authors:  J R Villada; P S Raj; T Akingbehin
Journal:  Br J Ophthalmol       Date:  1992-05       Impact factor: 4.638

2.  Factors influencing the accuracy of the SRK formula in the intraocular less power calculation.

Authors:  C Kalogeropoulos; M Aspiotis; M Stefaniotou; K Psilas
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

3.  Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length.

Authors:  Mohammad Miraftab; Hassan Hashemi; Akbar Fotouhi; Mehdi Khabazkhoob; Farhad Rezvan; Soheila Asgari
Journal:  Middle East Afr J Ophthalmol       Date:  2014 Oct-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.