Literature DB >> 7295134

Accuracy of ultrasound intraocular lens calculation.

K J Hoffer.   

Abstract

A review of the literature was made to evaluate the prediction accuracy of intraocular lens calculations. A uniform standard formula (percentage +/- 1.0 diopter/percentage +/- 2.0 D/range of error) for reporting accuracy was used to evaluate the accuracy of reports in the literature, as well as the accuracy of an ultrasound unit (Kretz 7100 MA), the HOffer formula, use of a standard 3.5-mm anterior chamber depth, and addition of a retinal thickness factor to the measured ultrasound axial length. The appropriateness of technicians performing this procedure also was evaluated. Results of previous studies show that the use of another ultrasound unit (Sonometrics DBR) and Binkhorst's formula is the least clinically accurate method.

Entities:  

Mesh:

Year:  1981        PMID: 7295134     DOI: 10.1001/archopht.1981.03930020693014

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  8 in total

1.  Accuracy of routine intraocular lens power calculation in a district general hospital.

Authors:  P T Gregory; R M Esbester; D L Boase
Journal:  Br J Ophthalmol       Date:  1989-01       Impact factor: 4.638

2.  Significance of intraocular lens power calculation.

Authors:  M Singh; A Dahalan
Journal:  Br J Ophthalmol       Date:  1987-11       Impact factor: 4.638

3.  A comparison of postoperative refractive results with and without intraocular lens power calculation.

Authors:  S M Thompson; V Mohan-Roberts
Journal:  Br J Ophthalmol       Date:  1986-01       Impact factor: 4.638

4.  Influence of the invariant refraction assumption in studies of formulas for monofocal and multifocal intraocular lens power calculation.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Noemi Burguera; David Piñero
Journal:  Int Ophthalmol       Date:  2022-02-08       Impact factor: 2.029

5.  Factors influencing the accuracy of the SRK formula in the intraocular less power calculation.

Authors:  C Kalogeropoulos; M Aspiotis; M Stefaniotou; K Psilas
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

6.  The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas.

Authors:  Jinho Jeong; Han Song; Jimmy K Lee; Roy S Chuck; Ji-Won Kwon
Journal:  BMC Ophthalmol       Date:  2017-05-02       Impact factor: 2.209

7.  Prediction Error Stabilization and Long-Term Standard Results with a Monofocal Intraocular Lens.

Authors:  Beatríz Macías-Murelaga; Gonzaga Garay-Aramburu; Roberto Bergado-Mijangos; Daniel Coello-Ojeda; Itziar Ozaeta; Pio Jésus Garcia-Gómez; Jesús Garrido-Fierro; Manuel Rodríguez-Vallejo; Joaquín Fernández
Journal:  Vision (Basel)       Date:  2022-01-13

Review 8.  Focused ultrasound in ophthalmology.

Authors:  Ronald H Silverman
Journal:  Clin Ophthalmol       Date:  2016-09-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.