Literature DB >> 29181432

Cochlear implant phantom for evaluating computed tomography acquisition parameters.

Srijata Chakravorti1, Brian J Bussey2, Yiyuan Zhao1, Benoit M Dawant1, Robert F Labadie3, Jack H Noble1.   

Abstract

Cochlear implants (CIs) are surgically implantable neuroprosthetic devices used to treat profound hearing loss. Recent literature indicates that there is a correlation between the final intracochlear positioning of the CI electrode arrays and the ultimate hearing outcome of the patient, indicating that further studies to better understand the relationship between electrode position and outcomes could have significant implications for future surgical techniques, array design, and processor programming methods. Postimplantation high-resolution computed tomography (CT) imaging is the best modality for localizing electrodes and provides the resolution necessary to visually identify electrode position, although with an unknown degree of accuracy depending on image acquisition parameters, like the hounsfield unit (HU) range of reconstruction, orientation, radiation dose, and image resolution. We report on the development of a phantom and on its use to study how four acquisition parameters, including image resolution and HU range of reconstruction, affect how accurately the true position of the electrodes can be found in a dataset of CT scans acquired from multiple helical and cone beam scanners. We also show how the phantom can be used to evaluate the effect of acquisition parameters on automatic electrode localization techniques.

Entities:  

Keywords:  cochlear implants; computed tomography; image quality; phantom

Year:  2017        PMID: 29181432      PMCID: PMC5689133          DOI: 10.1117/1.JMI.4.4.045002

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  28 in total

1.  Nondestructive three-dimensional analysis of electrode to modiolus proximity.

Authors:  Hartmut W Husstedt; Antje Aschendorff; Bernhard Richter; Roland Laszig; Martin Schumacher
Journal:  Otol Neurotol       Date:  2002-01       Impact factor: 2.311

2.  Blind deblurring of spiral CT images.

Authors:  Ming Jiang; Ge Wang; Margaret W Skinner; Jay T Rubinstein; Michael W Vannier
Journal:  IEEE Trans Med Imaging       Date:  2003-07       Impact factor: 10.048

3.  Computation of measures of effect size for neuroscience data sets.

Authors:  Harald Hentschke; Maik C Stüttgen
Journal:  Eur J Neurosci       Date:  2011-11-14       Impact factor: 3.386

4.  Design, analysis and simulation for development of the first clinical micro-CT scanner.

Authors:  Ge Wang; Shiying Zhao; Hengyong Yu; Charles A Miller; Paul J Abbas; Bruce J Gantz; Seung Wook Lee; Jay T Rubinstein
Journal:  Acad Radiol       Date:  2005-04       Impact factor: 3.173

5.  The generalisation of student's problems when several different population variances are involved.

Authors:  B L WELCH
Journal:  Biometrika       Date:  1947       Impact factor: 2.445

6.  Predicting error in rigid-body point-based registration.

Authors:  J M Fitzpatrick; J B West; C R Maurer
Journal:  IEEE Trans Med Imaging       Date:  1998-10       Impact factor: 10.048

7.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

8.  Automatic segmentation of intracochlear anatomy in conventional CT.

Authors:  Jack H Noble; Robert F Labadie; Omid Majdani; Benoit M Dawant
Journal:  IEEE Trans Biomed Eng       Date:  2011-06-23       Impact factor: 4.538

9.  In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays.

Authors:  D R Ketten; M W Skinner; G Wang; M W Vannier; G A Gates; J G Neely
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  1998-11

10.  In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea.

Authors:  Margaret W Skinner; Timothy A Holden; Bruce R Whiting; Arne H Voie; Barry Brunsden; J Gail Neely; Eugene A Saxon; Timothy E Hullar; Charles C Finley
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  2007-04
View more
  1 in total

1.  Automatic localization of closely spaced cochlear implant electrode arrays in clinical CTs.

Authors:  Yiyuan Zhao; Benoit M Dawant; Robert F Labadie; Jack H Noble
Journal:  Med Phys       Date:  2018-10-08       Impact factor: 4.071

  1 in total