Literature DB >> 12906237

Blind deblurring of spiral CT images.

Ming Jiang1, Ge Wang, Margaret W Skinner, Jay T Rubinstein, Michael W Vannier.   

Abstract

To discriminate fine anatomical features in the inner ear, it has been desirable that spiral computed tomography (CT) may perform beyond their current resolution limits with the aid of digital image processing techniques. In this paper, we develop a blind deblurring approach to enhance image resolution retrospectively without complete knowledge of the underlying point spread function (PSF). An oblique CT image can be approximated as the convolution of an isotropic Gaussian PSF and the actual cross section. Practically, the parameter of the PSF is often unavailable. Hence, estimation of the parameter for the underlying PSF is crucially important for blind image deblurring. Based on the iterative deblurring theory, we formulate an edge-to-noise ratio (ENR) to characterize the image quality change due to deblurring. Our blind deblurring algorithm estimates the parameter of the PSF by maximizing the ENR, and deblurs images. In the phantom studies, the blind deblurring algorithm reduces image blurring by about 24%, according to our blurring residual measure. Also, the blind deblurring algorithm works well in patient studies. After fully automatic blind deblurring, the conspicuity of the submillimeter features of the cochlea is substantially improved.

Entities:  

Mesh:

Year:  2003        PMID: 12906237     DOI: 10.1109/TMI.2003.815075

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  Cochlear implant phantom for evaluating computed tomography acquisition parameters.

Authors:  Srijata Chakravorti; Brian J Bussey; Yiyuan Zhao; Benoit M Dawant; Robert F Labadie; Jack H Noble
Journal:  J Med Imaging (Bellingham)       Date:  2017-11-16

2.  Harmonization of in-plane resolution in CT using multiple reconstructions from single acquisitions.

Authors:  Gonzalo Vegas-Sánchez-Ferrero; Gabriel Ramos-Llordén; Raúl San José Estépar
Journal:  Med Phys       Date:  2021-09-14       Impact factor: 4.071

3.  4D-CT-based motion correction of PET images using 3D iterative deconvolution.

Authors:  Lena Thomas; Thomas Schultz; Vesna Prokic; Matthias Guckenberger; Stephanie Tanadini-Lang; Melanie Hohberg; Markus Wild; Alexander Drzezga; Ralph A Bundschuh
Journal:  Oncotarget       Date:  2019-04-26
  3 in total