Design, analysis and simulation for development of the first clinical micro-CT scanner.

Ge Wang1, Shiying Zhao, Hengyong Yu, Charles A Miller, Paul J Abbas, Bruce J Gantz, Seung Wook Lee, Jay T Rubinstein.   

Abstract

In this article, we propose to develop the first clinical micro-CT (CMCT) system for human temporal bone imaging in vivo. This CMCT system consists of medical CT and micro-CT scanners either as separate components or in a combination, a cross-modality registration mechanism such as a facial surface scanner, and associated software. This system integrates the strengths of state-of-the-art medical CT and micro-CT techniques to achieve a spatial resolution that is much higher than currently available for inner ear imaging at acceptable dose levels. Our design, analysis, and simulation results demonstrate that the CMCT system is feasible for inner ear imaging and other clinical applications. For example, the CMCT system has the potential to improve the safety of guiding cochlear implant electrodes within the inner ear and assist the placement of inner ear microcatheters for delivery of gene modification therapy or administration of neurotrophic factors. Imaging of microarchitectures of the cancellous bone would be also an important application.

Entities:  

Mesh:

Year:  2005        PMID: 15831426     DOI: 10.1016/j.acra.2004.01.024

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  10 in total

1.  Modeling and measurement of the detector presampling MTF of a variable resolution x-ray CT scanner.

Authors:  Roman Melnyk; Frank A DiBianca
Journal:  Med Phys       Date:  2007-03       Impact factor: 4.071

2.  Enhanced repair of segmental bone defects in rabbit radius by porous tantalum scaffolds modified with the RGD peptide.

Authors:  Hui Wang; Qijia Li; Qian Wang; Hui Zhang; Wei Shi; Hongquan Gan; Huiping Song; Zhiqiang Wang
Journal:  J Mater Sci Mater Med       Date:  2017-02-14       Impact factor: 3.896

3.  A scheme for multisource interior tomography.

Authors:  Ge Wang; Hengyong Yu; Yangbo Ye
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

4.  Cochlear implant phantom for evaluating computed tomography acquisition parameters.

Authors:  Srijata Chakravorti; Brian J Bussey; Yiyuan Zhao; Benoit M Dawant; Robert F Labadie; Jack H Noble
Journal:  J Med Imaging (Bellingham)       Date:  2017-11-16

5.  Microarchitectural and mechanical characterization of the sickle bone.

Authors:  Mykel Green; Idowu Akinsami; Angela Lin; Shereka Banton; Samit Ghosh; Binbin Chen; Manu Platt; Ifeyinwa Osunkwo; Solomon Ofori-Acquah; Robert Guldberg; Gilda Barabino
Journal:  J Mech Behav Biomed Mater       Date:  2015-04-24

6.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

7.  Fast exact/quasi-exact FBP algorithms for triple-source helical cone-beam CT.

Authors:  Yang Lu; Alexander Katsevich; Jun Zhao; Hengyong Yu; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

Review 8.  The meaning of interior tomography.

Authors:  Ge Wang; Hengyong Yu
Journal:  Phys Med Biol       Date:  2013-08-02       Impact factor: 3.609

9.  Clinical Micro-CT Empowered by Interior Tomography, Robotic Scanning, and Deep Learning.

Authors:  Mengzhou Li; Zheng Fang; Wenxiang Cong; Chuang Niu; Weiwen Wu; Josef Uher; James Bennett; Jay T Rubinstein; G E Wang
Journal:  IEEE Access       Date:  2020-12-21       Impact factor: 3.367

10.  High-Resolution Methods for Diagnosing Cartilage Damage In Vivo.

Authors:  Kira D Novakofski; Sarah L Pownder; Matthew F Koff; Rebecca M Williams; Hollis G Potter; Lisa A Fortier
Journal:  Cartilage       Date:  2016-01       Impact factor: 4.634

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.