Literature DB >> 2914119

Evaluation of three methods for measurement of femoral neck anteversion. Femoral neck anteversion, definition, measuring methods and errors.

A Høiseth1, O Reikerås, E Fønstelien.   

Abstract

A variety of methods exist for determining femoral neck anteversion. There is, however, no consistent definition or reference method by which the correctness of the measurements can be determined. In this report the precision of a specific definition of femoral neck anteversion is estimated by means of a reference method. Three different radiologic measuring methods based on fundamentally different principles are evaluated by comparison with this reference. It is concluded that: 1) The Dunlap/Rippstein method can be recommended as the standard method. 2) Computed tomography may have substantial sources of error. 3) Methods based on arbitrary projections have poor precision.

Mesh:

Year:  1989        PMID: 2914119

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  8 in total

1.  Measurement of femoral neck anteversion in 3D. Part 2: 3D modelling method.

Authors:  J S Kim; T S Park; S B Park; J S Kim; I Y Kim; S I Kim
Journal:  Med Biol Eng Comput       Date:  2000-11       Impact factor: 2.602

2.  3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC system.

Authors:  Yeon Soo Lee; Seung Hoon Oh; Jong Keun Seon; Eun Kyoo Song; Taek Rim Yoon
Journal:  Med Biol Eng Comput       Date:  2006-09-29       Impact factor: 2.602

3.  A local reference frame for describing the proximal human femur: application in clinical settings.

Authors:  Milad Masjedi; Charison Tay; Simon J Harris; Justin P Cobb
Journal:  Skeletal Radiol       Date:  2013-12-18       Impact factor: 2.199

4.  Predicting anatomical landmarks and bone morphology of the femur using local region matching.

Authors:  Cong-Bo Phan; Seungbum Koo
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-02-12       Impact factor: 2.924

5.  Closed intramedullary derotational osteotomy and hip arthroscopy for cam femoroacetabular impingement from femoral retroversion.

Authors:  Dean K Matsuda; Nikhil Gupta; Hal D Martin
Journal:  Arthrosc Tech       Date:  2014-01-10

6.  Measurement of femoral neck anteversion in 3D. Part 1: 3D imaging method.

Authors:  J S Kim; T S Park; S B Park; J S Kim; I Y Kim; S I Kim
Journal:  Med Biol Eng Comput       Date:  2000-11       Impact factor: 2.602

7.  Femoral bowing plane adaptation to femoral anteversion.

Authors:  Alp Akman; Fahir Demirkan; Nuran Sabir; Murat Oto; Cagdas Yorukoglu; Esat Kiter
Journal:  Indian J Orthop       Date:  2017 Jan-Feb       Impact factor: 1.251

8.  Relationship between lower limb torsion and coronal morphologies of the femur and tibia in patients with medial knee osteoarthritis.

Authors:  Shuntaro Nejima; Yasushi Akamatsu; Hideo Kobayashi; Masaki Tsuji; Shota Mitsuhashi; Takahiro Sasaki; Ken Kumagai; Yutaka Inaba
Journal:  BMC Musculoskelet Disord       Date:  2020-04-17       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.