Portable abdomen radiography: moving to thickness-based protocols.

Adrian A Sánchez1, Ingrid Reiser2, Tina Baxter2, Yue Zhang2, Joshua H Finkle2, Zheng Feng Lu2, Kate A Feinstein2.   

Abstract

BACKGROUND: Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations.
OBJECTIVE: To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography.
MATERIALS AND METHODS: We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI.
RESULTS: Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart.
CONCLUSION: Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography.

Entities:  

Keywords:  Abdomen; Children; Exposure index; Image quality; Portable radiography; Protocol design; Radiography; Radiography protocols

Mesh:

Year:  2017        PMID: 29130139     DOI: 10.1007/s00247-017-4025-4

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  13 in total

1.  Quality assurance: a comparison study of radiographic exposure for neonatal chest radiographs at 4 academic hospitals.

Authors:  Mervyn D Cohen; Richard Markowitz; Jeanne Hill; Walter Huda; Paul Babyn; Bruce Apgar
Journal:  Pediatr Radiol       Date:  2011-11-06

2.  The standardized exposure index for digital radiography: an opportunity for optimization of radiation dose to the pediatric population.

Authors:  J Anthony Seibert; Richard L Morin
Journal:  Pediatr Radiol       Date:  2011-04-14

3.  Consequences of modern anthropometric dimensions for radiographic techniques and patient radiation exposures.

Authors:  Chintan Shah; A Kyle Jones; Charles E Willis
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

4.  Image gently: using exposure indicators to improve pediatric digital radiography.

Authors:  Quentin T Moore; Steven Don; Marilyn J Goske; Keith J Strauss; Mervyn Cohen; Tracy Herrmann; Robert Macdougall; Lauren Noble; Greg Morrison; Susan D John; Lois Lehman
Journal:  Radiol Technol       Date:  2012 Sep-Oct

5.  Patient size measured on CT images as a function of age at a tertiary care children's hospital.

Authors:  Patricia L Kleinman; Keith J Strauss; David Zurakowski; Kevin S Buckley; George A Taylor
Journal:  AJR Am J Roentgenol       Date:  2010-06       Impact factor: 3.959

6.  Quality assurance: using the exposure index and the deviation index to monitor radiation exposure for portable chest radiographs in neonates.

Authors:  Mervyn D Cohen; Matt L Cooper; Kelly Piersall; Bruce K Apgar
Journal:  Pediatr Radiol       Date:  2010-12-30

Review 7.  Strategies for dose reduction in ordinary radiographic examinations using CR and DR.

Authors:  C E Willis
Journal:  Pediatr Radiol       Date:  2004-10

8.  Effect of X-ray beam quality on determination of exposure index.

Authors:  Shogo Yasumatsu; Nobukazu Tanaka; Kensuke Iwase; Yoichiro Shimizu; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2015-11-30

Review 9.  Image gently campaign back to basics initiative: ten steps to help manage radiation dose in pediatric digital radiography.

Authors:  Steven Don; Robert Macdougall; Keith Strauss; Quentin T Moore; Marilyn J Goske; Mervyn Cohen; Tracy Herrmann; Susan D John; Lauren Noble; Greg Morrison; Lois Lehman; Bruce R Whiting
Journal:  AJR Am J Roentgenol       Date:  2013-05       Impact factor: 3.959

10.  Retrospective evaluation of exposure index (EI) values from plain radiographs reveals important considerations for quality improvement.

Authors:  Ursula Mothiram; Patrick C Brennan; John Robinson; Sarah J Lewis; Bernadette Moran
Journal:  J Med Radiat Sci       Date:  2013-11-20
View more
  1 in total

1.  Proper Management of the Clinical Exposure Index Based on Body Thickness Using Dose Optimization Tools in Digital Chest Radiography: A Phantom Study.

Authors:  Yongsu Yoon; Hyemin Park; Jungmin Kim; Jungsu Kim; Younghoon Roh; Nobukazu Tanaka; Junji Morishita
Journal:  Int J Environ Res Public Health       Date:  2021-05-13       Impact factor: 3.390

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.