Literature DB >> 21491197

The standardized exposure index for digital radiography: an opportunity for optimization of radiation dose to the pediatric population.

J Anthony Seibert1, Richard L Morin.   

Abstract

The exposure index is currently a method by which digital radiography manufacturers provide feedback to the technologist regarding the estimated exposure on the detector, as a surrogate for image signal-to-noise ratio and an indirect indication of digital image quality. Unfortunately, there are as many exposure index values and methods as there are manufacturers, and in an environment with multiple vendors and a need to share data across institutions and dose registry databases, the situation is complicated. Fortunately, a new exposure index of digital X-ray imaging systems has been implemented. Developed concurrently by the International Electrotechnical Commission and the American Association of Physicists in Medicine in cooperation with digital radiography system manufacturers, the index has been implemented as an international standard. As explained, the exposure index does not indicate patient dose but rather a linearly proportional estimate of the incident radiation exposure to the detector. However, the use of the standardized exposure index and its associated target exposure index and deviation index values will likely lead to improved technologist performance in terms of uniformity and use of optimized radiographic techniques, leading to safer care of children needing radiographic examinations. Radiologists will benefit from standardized terminology, and institutions and clinics will be able to compare exposure index values with others through a national dose index registry database now under development. The Alliance for Radiation Safety in Pediatric Imaging, in its role as a benefactor of and advocate for the pediatric patient, is using the Image Gently campaign to disseminate information regarding the exposure index standard for digital radiography so that these benefits can be achieved in a rapid and effective manner.

Entities:  

Mesh:

Year:  2011        PMID: 21491197      PMCID: PMC3076558          DOI: 10.1007/s00247-010-1954-6

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  1 in total

1.  An exposure indicator for digital radiography: AAPM Task Group 116 (executive summary).

Authors:  S Jeff Shepard; Jihong Wang; Michael Flynn; Eric Gingold; Lee Goldman; Kerry Krugh; David L Leong; Eugene Mah; Kent Ogden; Donald Peck; Ehsan Samei; Jihong Wang; Charles E Willis
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

  1 in total
  18 in total

1.  How many strikes does it take till we are out?

Authors:  Thomas L Slovis; Keith J Strauss; Donald P Frush
Journal:  Pediatr Radiol       Date:  2011-04-14

2.  [Dose reduction and adequate image quality in digital radiography: a contradiction?].

Authors:  S Pötter-Lang; M Dünkelmeyer; M Uffmann
Journal:  Radiologe       Date:  2012-10       Impact factor: 0.635

3.  Portable abdomen radiography: moving to thickness-based protocols.

Authors:  Adrian A Sánchez; Ingrid Reiser; Tina Baxter; Yue Zhang; Joshua H Finkle; Zheng Feng Lu; Kate A Feinstein
Journal:  Pediatr Radiol       Date:  2017-11-12

4.  [Specific characteristics of chest X‑ray in childhood : Basics for radiologists].

Authors:  K Schneider
Journal:  Radiologe       Date:  2018-04       Impact factor: 0.635

5.  Evaluation of the effects of subject thickness on the exposure index in digital radiography.

Authors:  Takeshi Takaki; Kazuki Takeda; Seiichi Murakami; Haruhisa Ogawa; Masato Ogawa; Masatoshi Sakamoto
Journal:  Radiol Phys Technol       Date:  2015-11-27

6.  Effect of X-ray beam quality on determination of exposure index.

Authors:  Shogo Yasumatsu; Nobukazu Tanaka; Kensuke Iwase; Yoichiro Shimizu; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2015-11-30

7.  Patient dose management solution directly integrated in the RIS: "Gray Detector" software.

Authors:  A Nitrosi; A Corazza; M Bertolini; R Sghedoni; P Pattacini; M Iori
Journal:  J Digit Imaging       Date:  2014-12       Impact factor: 4.056

8.  A method to derive appropriate exposure parameters from target exposure index and patient thickness in pediatric digital radiography.

Authors:  Menglong Zhang; Kai Liu; Xuecai Niu; Xinli Liu
Journal:  Pediatr Radiol       Date:  2012-12-04

9.  Method of determining technique from weight and height to achieve targeted detector exposures in portable chest and abdominal digital radiography.

Authors:  Matthew Hoerner; Kevin Grizzard; Jennifer Moroz
Journal:  J Appl Clin Med Phys       Date:  2022-03-09       Impact factor: 2.243

10.  Proper Management of the Clinical Exposure Index Based on Body Thickness Using Dose Optimization Tools in Digital Chest Radiography: A Phantom Study.

Authors:  Yongsu Yoon; Hyemin Park; Jungmin Kim; Jungsu Kim; Younghoon Roh; Nobukazu Tanaka; Junji Morishita
Journal:  Int J Environ Res Public Health       Date:  2021-05-13       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.