Literature DB >> 29038997

Multiparticle Simulations of Quadrupolar Ion Detection in an Ion Cyclotron Resonance Cell with Four Narrow Aperture Detection Electrodes.

Joshua A Driver1, Konstantin O Nagornov2, Anton N Kozhinov2, Yury O Tsybin2, Andriy Kharchenko1,3, I Jonathan Amster4.   

Abstract

The current paradigm in FT-ICR cell design is to approximate the ideal three-dimensional quadratic trapping potential as closely as possible to maintain ion cloud spatial coherence and achieve long transients, either with hyperbolically shaped electrodes, shimming electrodes, or by dynamic harmonization. In sharp contrast, the FT-ICR analyzer cell with four narrow aperture detection electrodes (NADEL) introduces significant anharmonic terms to the trapping potential. This analyzer cell is capable of quadrupolar detection by which one can measure a signal that is close to the unperturbed cyclotron frequency. This is far less sensitive to trapping potential and space charge shifts than the reduced cyclotron frequency measured in conventional ICR cells. The quadrupolar mode of ion detection in NADEL cells has been examined previously by SIMION simulations of ion clouds with up to 500 ions per simulation. Here, the behavior of the NADEL analyzer cell is examined through particle-in-cell (PIC) simulations, which allows us to examine the behavior of large populations (tens of thousands) of ions with space charge considerations, and to calculate the induced charge on the NADEL detection electrodes, and thus the transient signal. PIC simulations confirm a unique spatial distribution of the ions, with a coherent motion that results in long transient signals. Dependence of the ion cloud and image current signal on cell design, ion energy, and magnetron radius are examined. Coalescence effects are compared with those found in a dynamically harmonized cell. The insensitivity of the measured cyclotron frequency to space-charge is demonstrated both with simulations and experimentally. Graphical Abstract ᅟ.

Entities:  

Keywords:  Analyzer cell; FTICR; Fourier transform mass spectrometry; Ion motion simulations

Year:  2017        PMID: 29038997     DOI: 10.1007/s13361-017-1817-6

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  18 in total

1.  Fourier transform ion cyclotron resonance mass resolution and dynamic range limits calculated by computer modeling of ion cloud motion.

Authors:  Gleb Vladimirov; Christopher L Hendrickson; Greg T Blakney; Alan G Marshall; Ron M A Heeren; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-27       Impact factor: 3.109

2.  Performance of Orbitrap mass analyzer at various space charge and non-ideal field conditions: simulation approach.

Authors:  Andriy Kharchenko; Gleb Vladimirov; Ron M A Heeren; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2012-02-22       Impact factor: 3.109

3.  Initial experimental characterization of a new ultra-high resolution FTICR cell with dynamic harmonization.

Authors:  Eugene N Nikolaev; Ivan A Boldin; Roland Jertz; Gökhan Baykut
Journal:  J Am Soc Mass Spectrom       Date:  2011-04-19       Impact factor: 3.109

4.  Analyzing complex FTMS simulations: a case study in high-level visualization of ion motions.

Authors:  Wojciech Burakiewicz; Robert van Liere
Journal:  IEEE Trans Vis Comput Graph       Date:  2006 Sep-Oct       Impact factor: 4.579

5.  Ion trap with narrow aperture detection electrodes for Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Konstantin O Nagornov; Anton N Kozhinov; Oleg Y Tsybin; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2015-03-14       Impact factor: 3.109

6.  Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.

Authors:  Konstantin O Nagornov; Anton N Kozhinov; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2017-02-17       Impact factor: 3.109

7.  Petroleomics by electrospray ionization FT-ICR mass spectrometry coupled to partial least squares with variable selection methods: prediction of the total acid number of crude oils.

Authors:  Luciana A Terra; Paulo R Filgueiras; Lílian V Tose; Wanderson Romão; Douglas D de Souza; Eustáquio V R de Castro; Mirela S L de Oliveira; Júlio C M Dias; Ronei J Poppi
Journal:  Analyst       Date:  2014-10-07       Impact factor: 4.616

8.  Trapping ring electrode cell: a FTICR mass spectrometer cell for improved signal-to-noise and resolving power.

Authors:  Chad R Weisbrod; Nathan K Kaiser; Gunnar E Skulason; James E Bruce
Journal:  Anal Chem       Date:  2008-08-06       Impact factor: 6.986

9.  An electrically compensated trap designed to eighth order for FT-ICR mass spectrometry.

Authors:  Adam M Brustkern; Don L Rempel; Michael L Gross
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-02       Impact factor: 3.109

10.  Comparison of particle-in-cell simulations with experimentally observed frequency shifts between ions of the same mass-to-charge in Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Franklin E Leach; Andriy Kharchenko; Ron M A Heeren; Eugene Nikolaev; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2009-10-06       Impact factor: 3.109

View more
  1 in total

1.  Cyclotron Phase-Coherent Ion Spatial Dispersion in a Non-Quadratic Trapping Potential is Responsible for FT-ICR MS at the Cyclotron Frequency.

Authors:  Konstantin O Nagornov; Anton N Kozhinov; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2017-11-08       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.