Literature DB >> 21953094

Initial experimental characterization of a new ultra-high resolution FTICR cell with dynamic harmonization.

Eugene N Nikolaev1, Ivan A Boldin, Roland Jertz, Gökhan Baykut.   

Abstract

A new Fourier transform ion cyclotron resonance (FTICR) cell based on completely new principles of formation of the effective electric potential distribution in Penning type traps, Boldin and Nikolaev (Proceedings of the 58th ASMS Conference, 2010), Boldin and Nikolaev (Rapid Commun Mass Spectrom 25:122-126, 2011) is constructed and tested experimentally. Its operation is based on the concept of electric potential space-averaging via charged particle cyclotron motion. Such an averaging process permits an effective electric force distribution in the entire volume of a cylindrical Penning trap to be equal to its distribution in the field created by hyperbolic electrodes in an ideal Penning trap. The excitation and detection electrodes of this new cell are shaped for generating a quadratic dependence on axial coordinates of an averaged (along cyclotron motion orbit) electric potential at any radius of the cyclotron motion. These electrodes together with the trapping segments form a cylindrical surface like in a conventional cylindrical cell. In excitation mode this cell being elongated behaves almost like an open cylindrical cell of the same length. It is more effective in ion motion harmonization at larger cyclotron radii than a Gabrielse et al.-type (Int J Mass Spectrom Ion Processes 88:319-332, 1989) cylindrical cell with four compensation sections. A mass resolving power of more than twenty millions of reserpine (m/z 609) and more than one million of highly charged BSA molecular ions (m/z 1357) has been obtained in a 7T magnetic field.

Mesh:

Substances:

Year:  2011        PMID: 21953094     DOI: 10.1007/s13361-011-0125-9

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  9 in total

1.  A novel high-performance fourier transform ion cyclotron resonance cell for improved biopolymer characterization.

Authors:  J E Bruce; G A Anderson; C Y Lin; M Gorshkov; A L Rockwood; R D Smith
Journal:  J Mass Spectrom       Date:  2000-01       Impact factor: 1.982

2.  Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly.

Authors:  Ivan A Boldin; Eugene N Nikolaev
Journal:  Rapid Commun Mass Spectrom       Date:  2011-01-15       Impact factor: 2.419

3.  Realistic modeling of ion cloud motion in a Fourier transform ion cyclotron resonance cell by use of a particle-in-cell approach.

Authors:  Eugene N Nikolaev; Ron M A Heeren; Alexander M Popov; Alexander V Pozdneev; Konstantin S Chingin
Journal:  Rapid Commun Mass Spectrom       Date:  2007       Impact factor: 2.419

4.  Trapped-ion cell with improved DC potential harmonicity for FT-ICR MS.

Authors:  Aleksey V Tolmachev; Errol W Robinson; Si Wu; Hyuk Kang; Natacha M Lourette; Ljiljana Pasa-Tolić; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2008-01-31       Impact factor: 3.109

Review 5.  Fourier transform ion cyclotron resonance mass spectrometry: a primer.

Authors:  A G Marshall; C L Hendrickson; G S Jackson
Journal:  Mass Spectrom Rev       Date:  1998 Jan-Feb       Impact factor: 10.946

6.  A "screened" electrostatic ion trap for enhanced mass resolution, mass accuracy, reproducibility, and upper mass limit in Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  M Wang; A G Marshall
Journal:  Anal Chem       Date:  1989-06-01       Impact factor: 6.986

7.  Parametric mode operation of a hyperbolic Penning trap for Fourier transform mass spectrometry.

Authors:  D L Rempel; E B Ledford; S K Huang; M L Gross
Journal:  Anal Chem       Date:  1987-10-15       Impact factor: 6.986

8.  Trapping ring electrode cell: a FTICR mass spectrometer cell for improved signal-to-noise and resolving power.

Authors:  Chad R Weisbrod; Nathan K Kaiser; Gunnar E Skulason; James E Bruce
Journal:  Anal Chem       Date:  2008-08-06       Impact factor: 6.986

9.  An electrically compensated trap designed to eighth order for FT-ICR mass spectrometry.

Authors:  Adam M Brustkern; Don L Rempel; Michael L Gross
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-02       Impact factor: 3.109

  9 in total
  34 in total

1.  A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry.

Authors:  Tzu-Yung Lin; Roger J Green; Peter B O'Connor
Journal:  Rev Sci Instrum       Date:  2011-12       Impact factor: 1.523

2.  Performance of Orbitrap mass analyzer at various space charge and non-ideal field conditions: simulation approach.

Authors:  Andriy Kharchenko; Gleb Vladimirov; Ron M A Heeren; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2012-02-22       Impact factor: 3.109

3.  Angular averaged profiling of the radial electric field in compensated FTICR Cells.

Authors:  Aleksey V Tolmachev; Errol W Robinson; Si Wu; Richard D Smith; Jean H Futrell; Ljiljana Paša-Tolić
Journal:  J Am Soc Mass Spectrom       Date:  2012-05-08       Impact factor: 3.109

4.  Mass resolution and mass accuracy: how much is enough?

Authors:  Alan G Marshall; Greg T Blakney; Tong Chen; Nathan K Kaiser; Amy M McKenna; Ryan P Rodgers; Brian M Ruddy; Feng Xian
Journal:  Mass Spectrom (Tokyo)       Date:  2013-04-15

5.  From Supercomputer Modeling to Highest Mass Resolution in FT-ICR.

Authors:  Evgene N Nikolaev; Gleb N Vladimirov; Roland Jertz; Gökhan Baykut
Journal:  Mass Spectrom (Tokyo)       Date:  2013-04-15

6.  Elemental composition validation from stored waveform inverse Fourier transform (SWIFT) isolation FT-ICR MS isotopic fine structure.

Authors:  Brian M Ruddy; Gregory T Blakney; Ryan P Rodgers; Christopher L Hendrickson; Alan G Marshall
Journal:  J Am Soc Mass Spectrom       Date:  2013-08-06       Impact factor: 3.109

7.  Unit mass baseline resolution for an intact 148 kDa therapeutic monoclonal antibody by Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Santosh G Valeja; Nathan K Kaiser; Feng Xian; Christopher L Hendrickson; Jason C Rouse; Alan G Marshall
Journal:  Anal Chem       Date:  2011-10-20       Impact factor: 6.986

8.  Resolving isotopic fine structure to detect and quantify natural abundance- and hydrogen/deuterium exchange-derived isotopomers.

Authors:  Qian Liu; Michael L Easterling; Jeffrey N Agar
Journal:  Anal Chem       Date:  2013-12-20       Impact factor: 6.986

9.  Front-End Electron Transfer Dissociation Coupled to a 21 Tesla FT-ICR Mass Spectrometer for Intact Protein Sequence Analysis.

Authors:  Chad R Weisbrod; Nathan K Kaiser; John E P Syka; Lee Early; Christopher Mullen; Jean-Jacques Dunyach; A Michelle English; Lissa C Anderson; Greg T Blakney; Jeffrey Shabanowitz; Christopher L Hendrickson; Alan G Marshall; Donald F Hunt
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-18       Impact factor: 3.109

Review 10.  Mass spectrometry of natural products: current, emerging and future technologies.

Authors:  Amina Bouslimani; Laura M Sanchez; Neha Garg; Pieter C Dorrestein
Journal:  Nat Prod Rep       Date:  2014-05-07       Impact factor: 13.423

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.