Performance of Orbitrap mass analyzer at various space charge and non-ideal field conditions: simulation approach.

Andriy Kharchenko1, Gleb Vladimirov, Ron M A Heeren, Eugene N Nikolaev.   

Abstract

The orbital trap mass analyzer provides a number of unique analytical features along with inevitable limitations as an electrostatic instrument operating in high space charge regimes resulting in systematic measured frequency errors as an effect of stored ion clouds on the trap field and each other effect of non-ideal machining the trap electrodes, effect of injection slot, effect of real versus theoretical trap dimensions, etc. This paper deals with determining the influence of the space charge effect and imperfection of the electrostatic field on the motion of ion ensembles in the orbital trap. We examine effects of theoretically modeled non-harmonicity of the electrostatic potential and the number of confined ions on stability of coherent ion motion in the trap that determines the frequency shifts of axial ion oscillation. Three different Orbitrap geometries were considered: geometry close to preproduction Orbitrap, close to standard Orbitrap, close to high field Orbitrap. Frequency shifts for m/z = 500 and for charge state +23 of cytochrome c isotopic cluster particles with 10(4)-6*10(6) elemental charges in the trap were considered. Refined spectra were calculated using the filter diagonalization method proposed by Mandelshtam et al. and applied to mass spectrometry by O'Connor and Aizikov.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22354683     DOI: 10.1007/s13361-011-0325-3

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

1.  Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis

Authors: 
Journal:  Anal Chem       Date:  2000-03-15       Impact factor: 6.986

2.  Interfacing the orbitrap mass analyzer to an electrospray ion source.

Authors:  Mark Hardman; Alexander A Makarov
Journal:  Anal Chem       Date:  2003-04-01       Impact factor: 6.986

3.  Initial experimental characterization of a new ultra-high resolution FTICR cell with dynamic harmonization.

Authors:  Eugene N Nikolaev; Ivan A Boldin; Roland Jertz; Gökhan Baykut
Journal:  J Am Soc Mass Spectrom       Date:  2011-04-19       Impact factor: 3.109

4.  Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly.

Authors:  Ivan A Boldin; Eugene N Nikolaev
Journal:  Rapid Commun Mass Spectrom       Date:  2011-01-15       Impact factor: 2.419

5.  The Orbitrap: a new mass spectrometer.

Authors:  Qizhi Hu; Robert J Noll; Hongyan Li; Alexander Makarov; Mark Hardman; R Graham Cooks
Journal:  J Mass Spectrom       Date:  2005-04       Impact factor: 1.982

6.  Use of the filter diagonalization method in the study of space charge related frequency modulation in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Konstantin Aizikov; Peter B O'Connor
Journal:  J Am Soc Mass Spectrom       Date:  2006-04-17       Impact factor: 3.109

7.  Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer.

Authors:  Alexander Makarov; Eduard Denisov; Alexander Kholomeev; Wilko Balschun; Oliver Lange; Kerstin Strupat; Stevan Horning
Journal:  Anal Chem       Date:  2006-04-01       Impact factor: 6.986

8.  Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer.

Authors:  Alexander Makarov; Eduard Denisov; Oliver Lange; Stevan Horning
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-05       Impact factor: 3.109

Review 9.  Orbitrap mass spectrometry: instrumentation, ion motion and applications.

Authors:  Richard H Perry; R Graham Cooks; Robert J Noll
Journal:  Mass Spectrom Rev       Date:  2008 Nov-Dec       Impact factor: 10.946

Review 10.  Fourier transform ion cyclotron resonance mass spectrometry: a primer.

Authors:  A G Marshall; C L Hendrickson; G S Jackson
Journal:  Mass Spectrom Rev       Date:  1998 Jan-Feb       Impact factor: 10.946

View more
  10 in total

1.  Space charge induced nonlinear effects in quadrupole ion traps.

Authors:  Dan Guo; Yuzhuo Wang; Xingchuang Xiong; Hua Zhang; Xiaohua Zhang; Tao Yuan; Xiang Fang; Wei Xu
Journal:  J Am Soc Mass Spectrom       Date:  2014-01-03       Impact factor: 3.109

2.  Accelerated simulation study of space charge effects in quadrupole ion traps using GPU techniques.

Authors:  Xingchuang Xiong; Wei Xu; Xiang Fang; Yulin Deng; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2012-08-09       Impact factor: 3.109

3.  Twelve million resolving power on 4.7 T Fourier transform ion cyclotron resonance instrument with dynamically harmonized cell--observation of fine structure in peptide mass spectra.

Authors:  Igor A Popov; Konstantin Nagornov; Gleb N Vladimirov; Yury I Kostyukevich; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2014-03-07       Impact factor: 3.109

4.  Preliminary Figures of Merit for Isotope Ratio Measurements: The Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Ionization Source Coupled to an Orbitrap Mass Analyzer.

Authors:  Edward D Hoegg; Charles J Barinaga; George J Hager; Garret L Hart; David W Koppenaal; R Kenneth Marcus
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-14       Impact factor: 3.109

5.  Multiparticle Simulations of Quadrupolar Ion Detection in an Ion Cyclotron Resonance Cell with Four Narrow Aperture Detection Electrodes.

Authors:  Joshua A Driver; Konstantin O Nagornov; Anton N Kozhinov; Yury O Tsybin; Andriy Kharchenko; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2017-10-16       Impact factor: 3.109

6.  Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.

Authors:  Jeremy A Barry; Guillaume Robichaud; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

7.  Qualitative and quantitative top-down mass spectral analysis of crustacean hyperglycemic hormones in response to feeding.

Authors:  Chenxi Jia; Qing Yu; Jingxin Wang; Lingjun Li
Journal:  Proteomics       Date:  2014-03-20       Impact factor: 3.984

8.  MSIWarp: A General Approach to Mass Alignment in Mass Spectrometry Imaging.

Authors:  Jonatan O Eriksson; Alejandro Sánchez Brotons; Melinda Rezeli; Frank Suits; György Markó-Varga; Peter Horvatovich
Journal:  Anal Chem       Date:  2020-12-02       Impact factor: 6.986

9.  Optimization of mass spectrometry settings for steroidomic analysis in young and old killifish.

Authors:  Rahel Dabrowski; Roberto Ripa; Christian Latza; Andrea Annibal; Adam Antebi
Journal:  Anal Bioanal Chem       Date:  2020-04-24       Impact factor: 4.142

10.  Frequency chasing of individual megadalton ions in an Orbitrap analyser improves precision of analysis in single-molecule mass spectrometry.

Authors:  Tobias P Wörner; Konstantin Aizikov; Joost Snijder; Kyle L Fort; Alexander A Makarov; Albert J R Heck
Journal:  Nat Chem       Date:  2022-03-10       Impact factor: 24.274

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.