Comparison of particle-in-cell simulations with experimentally observed frequency shifts between ions of the same mass-to-charge in Fourier transform ion cyclotron resonance mass spectrometry.

Franklin E Leach1, Andriy Kharchenko, Ron M A Heeren, Eugene Nikolaev, I Jonathan Amster.   

Abstract

It has been previously observed that the measured frequency of ions in a Fourier transform mass spectrometry experiment depend upon the number of trapped ions, even for populations consisting exclusively of a single mass-to-charge. Since ions of the same mass-to-charge are thought not to exert a space-charge effect among themselves, the experimental observation of such frequency shifts raises questions about their origin. To determine the source of such experimentally observed frequency shifts, multiparticle ion trajectory simulations have been conducted on monoisotopic populations of Cs(+) ranging from 10(2) ions to 10(6) ions. A close match to experimental behavior is observed. By probing the effect of ion number and orbital radius on the shift in the cyclotron frequency, it is shown that for a monoisotopic population of ions, the frequency shift is caused by the interaction of ions with their image-charge. The addition of ions of a second mass-to-charge to the simulation allows the comparison of the magnitude of the frequency shift resulting from space-charge (ion-ion) effects versus ion interactions with their image charge. 2010. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19896390      PMCID: PMC4451813          DOI: 10.1016/j.jasms.2009.10.001

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  12 in total

1.  Mass measurement errors caused by 'local" frequency perturbations in FTICR mass spectrometry.

Authors:  Christophe Masselon; Aleksey V Tolmachev; Gordon A Anderson; Richard Harkewicz; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2002-01       Impact factor: 3.109

2.  Use of the filter diagonalization method in the study of space charge related frequency modulation in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Konstantin Aizikov; Peter B O'Connor
Journal:  J Am Soc Mass Spectrom       Date:  2006-04-17       Impact factor: 3.109

3.  Analyzing complex FTMS simulations: a case study in high-level visualization of ion motions.

Authors:  Wojciech Burakiewicz; Robert van Liere
Journal:  IEEE Trans Vis Comput Graph       Date:  2006 Sep-Oct       Impact factor: 4.579

4.  Analysis and elimination of systematic errors originating from coulomb mutual interaction and image charge in Fourier transform ion cyclotron resonance precise mass difference measurements.

Authors:  M V Gorshkov; A G Marshall; E N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  1993-11       Impact factor: 3.109

5.  Experimental Evidence for Space-Charge Effects between Ions of the Same Mass-to-Charge in Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry.

Authors:  Richard L Wong; I Jonathan Amster
Journal:  Int J Mass Spectrom       Date:  2007-09-01       Impact factor: 1.986

6.  Cyclotron motion of two Coulombically interacting ion clouds with implications to Fourier-transform ion cyclotron resonance mass spectrometry.

Authors: 
Journal:  Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics       Date:  1995-10

7.  Routine Part-per-Million Mass Accuracy for High- Mass Ions:  Space-Charge Effects in MALDI FT-ICR.

Authors:  M L Easterling; T H Mize; I J Amster
Journal:  Anal Chem       Date:  1999-02-01       Impact factor: 6.986

8.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

9.  Statistical evaluation of internal and external mass calibration laws utilized in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  David C Muddiman; Ann L Oberg
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

10.  Electron detachment dissociation of glycosaminoglycan tetrasaccharides.

Authors:  Jeremy J Wolff; I Jonathan Amster; Lianli Chi; Robert J Linhardt
Journal:  J Am Soc Mass Spectrom       Date:  2006-10-30       Impact factor: 3.109

View more
  10 in total

1.  Fourier transform ion cyclotron resonance mass resolution and dynamic range limits calculated by computer modeling of ion cloud motion.

Authors:  Gleb Vladimirov; Christopher L Hendrickson; Greg T Blakney; Alan G Marshall; Ron M A Heeren; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-27       Impact factor: 3.109

2.  A novel 9.4 tesla FTICR mass spectrometer with improved sensitivity, mass resolution, and mass range.

Authors:  Nathan K Kaiser; John P Quinn; Gregory T Blakney; Christopher L Hendrickson; Alan G Marshall
Journal:  J Am Soc Mass Spectrom       Date:  2011-05-05       Impact factor: 3.109

3.  Ion Behavior in an Electrically Compensated Ion Cyclotron Resonance Trap.

Authors:  Adam M Brustkern; Don L Rempel; Michael L Gross
Journal:  Int J Mass Spectrom       Date:  2011-03-01       Impact factor: 1.986

4.  Mass resolution and mass accuracy: how much is enough?

Authors:  Alan G Marshall; Greg T Blakney; Tong Chen; Nathan K Kaiser; Amy M McKenna; Ryan P Rodgers; Brian M Ruddy; Feng Xian
Journal:  Mass Spectrom (Tokyo)       Date:  2013-04-15

5.  Twelve million resolving power on 4.7 T Fourier transform ion cyclotron resonance instrument with dynamically harmonized cell--observation of fine structure in peptide mass spectra.

Authors:  Igor A Popov; Konstantin Nagornov; Gleb N Vladimirov; Yury I Kostyukevich; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2014-03-07       Impact factor: 3.109

6.  Reducing Space Charge Effects in a Linear Ion Trap by Rhombic Ion Excitation and Ejection.

Authors:  Xiaohua Zhang; Yuzhuo Wang; Lili Hu; Dan Guo; Xiang Fang; Mingfei Zhou; Wei Xu
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-14       Impact factor: 3.109

7.  Multiparticle Simulations of Quadrupolar Ion Detection in an Ion Cyclotron Resonance Cell with Four Narrow Aperture Detection Electrodes.

Authors:  Joshua A Driver; Konstantin O Nagornov; Anton N Kozhinov; Yury O Tsybin; Andriy Kharchenko; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2017-10-16       Impact factor: 3.109

8.  Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.

Authors:  Jeremy A Barry; Guillaume Robichaud; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

9.  Autophaser: an algorithm for automated generation of absorption mode spectra for FT-ICR MS.

Authors:  David P A Kilgour; Rebecca Wills; Yulin Qi; Peter B O'Connor
Journal:  Anal Chem       Date:  2013-03-26       Impact factor: 6.986

10.  Physiotherapeutic Reduction of Orofacial Pain Using Extremely Low-Frequency Electromagnetic Field and Light-Emitting Diode Therapy-A Pilot Study.

Authors:  Danuta Lietz-Kijak; Roman Ardan
Journal:  Pain Res Manag       Date:  2022-02-08       Impact factor: 3.037

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.