Literature DB >> 28197703

Contemporary dual-mobility cup regional and private register: methodology and results.

André Ferreira1, Jean-Louis Prudhon2, Régis Verdier3, Jean-Marc Puch4, Loys Descamps4, Guy Dehri5, Marcel Remi6, Jacques H Caton7.   

Abstract

INTRODUCTION: The dual-mobility cup (DMC) was introduced in 1979. Due to lack of referenced publications, this interesting and innovating concept was ignored during close to 20 years. However, 180 studies (level III or IV) have now been published. Evidence-based medicine is based on level I studies. Over the past three decades, the role of national registries developed with the intention of surveying orthopaedic implants. In 2012, we developed, registered, and implemented a specific database for contemporary DMC.
MATERIAL AND METHODS: Data are collected with an electronic case-report form, and this evaluation is limited to a single product line . From May 2012 to December 2016, 2090 cases of Quattro cup implantation have been registered; results of the first 636 primary cases with a minimum follow-up of three years were previously reported (series 1). Of the 1454 remaining cases, dislocation rate only was monitored (series 2) and results are reported here.
RESULTS: In series1 comprising 553 degenerative diseases and 83 proximal femoral fractures (PFF), one dislocation (1.2%) occurred in PFF and none in degenerative disease. Survivorship (infection excluded) at three years was 99.8%. In series 2 (1315 degenerative diseases; 139 PFFs), dislocation rate was 0.27% (four cases). In neither series did we observe any intraprosthetic dislocation. DISCUSSION: Results of this private regional register confirm the high efficiency of DMC to decrease dislocation rate (0.23%). Few outcomes of DMC in primary total hip arthroplasty (THA) are published in national registries. The Swedish Hip Arthroplasty Register has reported on 287 primary DMC hips of 78,098 THAs. No dislocations were reported. We conclude that DMC decreases dislocation rate, and the national registry of Lithuania also reports a significant decrease in the rate of revision for dislocation in the DMC group. These data-available online-allow us to monitor DMC in real time, although they lack short-term follow-up.

Entities:  

Keywords:  Dislocation; Dual-mobility cup; Register; Total hip arthroplasty

Mesh:

Year:  2017        PMID: 28197703     DOI: 10.1007/s00264-017-3405-6

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  13 in total

1.  The dual mobility socket concept: experience with 668 cases.

Authors:  Claude Vielpeau; Benoit Lebel; Ludovic Ardouin; Gilles Burdin; Christine Lautridou
Journal:  Int Orthop       Date:  2010-12-24       Impact factor: 3.075

2.  Dual mobility cup: dislocation rate and survivorship at ten years of follow-up.

Authors:  Jean-Louis Prudhon; André Ferreira; Régis Verdier
Journal:  Int Orthop       Date:  2013-09-13       Impact factor: 3.075

3.  Evora® chromium-cobalt dual mobility socket: results at a minimum 10 years' follow-up.

Authors:  S Leclercq; J Y Benoit; J P de Rosa; E Tallier; C Leteurtre; P H Girardin
Journal:  Orthop Traumatol Surg Res       Date:  2013-10-29       Impact factor: 2.256

4.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

5.  [Survival of the cementless Bousquet dual mobility cup: Minimum 15-year follow-up of 437 total hip arthroplasties].

Authors:  C Lautridou; B Lebel; G Burdin; C Vielpeau
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2008-07-24

6.  The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty.

Authors:  Daniel J Berry; Marius von Knoch; Cathy D Schleck; W Scott Harmsen
Journal:  J Bone Joint Surg Am       Date:  2004-01       Impact factor: 5.284

7.  A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk.

Authors:  Jacques H Caton; Jean Louis Prudhon; André Ferreira; Thierry Aslanian; Régis Verdier
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

Review 8.  Total hip arthroplasty versus hemiarthroplasty for displaced femoral neck fractures in the healthy elderly: a meta-analysis and systematic review of randomized trials.

Authors:  Paul T P W Burgers; Arnoud R Van Geene; Michel P J Van den Bekerom; Esther M M Van Lieshout; Bastiaan Blom; Ilyas S Aleem; M Bhandari; Rudolf W Poolman
Journal:  Int Orthop       Date:  2012-05-24       Impact factor: 3.075

9.  Trans trochanteric approach with coronal osteotomy of the great trochanter: A new technique for extra-capsular trochanteric fracture patients treated by total hip arthroplasty (THA) in elderly.

Authors:  Francois Steffann; Jean-Louis Prudhon; Jean-Marc Puch; André Ferreira; Loys Descamps; Régis Verdier; Jacques Caton
Journal:  SICOT J       Date:  2015-06-05

10.  The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis. An analysis of 78,098 operations in the Swedish Hip Arthroplasty Register.

Authors:  Nils P Hailer; Rüdiger J Weiss; André Stark; Johan Kärrholm
Journal:  Acta Orthop       Date:  2012-10-08       Impact factor: 3.717

View more
  11 in total

1.  Dual-mobility cup: a new French revolution.

Authors:  Jacques Henri Caton; André Ferreira
Journal:  Int Orthop       Date:  2017-02-14       Impact factor: 3.075

2.  High-volume surgeons and high-volume journals in a multivariate orthopedic environment.

Authors:  Marius M Scarlat; Marko Pećina; Andrew Quaile
Journal:  Int Orthop       Date:  2018-09       Impact factor: 3.075

3.  Pelvic reconstructions following peri-acetabular bone tumour resections using a cementless ice-cream cone prosthesis with dual mobility cup.

Authors:  Samir-Pierre Issa; David Biau; Antoine Babinet; Valérie Dumaine; Malo Le Hanneur; Philippe Anract
Journal:  Int Orthop       Date:  2018-01-27       Impact factor: 3.075

4.  Equal access to orthopaedic research funding, databases and scientific publications.

Authors:  Marius M Scarlat; Cyril Mauffrey; Andreas Mavrogenis
Journal:  Int Orthop       Date:  2019-10       Impact factor: 3.075

5.  Intraprosthetic dislocation of dual mobility total hip arthroplasty: still occurring?

Authors:  Thomas Neri; Bertrand Boyer; Jean Geringer; Alexandre Di Iorio; Jacques H Caton; Remi PhiIippot; Frederic Farizon
Journal:  Int Orthop       Date:  2018-07-19       Impact factor: 3.075

6.  Successful initial experience with a novel outpatient total hip arthroplasty program in a public health system in Chile.

Authors:  Orlando Paredes; Rodrigo Ñuñez; Ianiv Klaber
Journal:  Int Orthop       Date:  2018-03-21       Impact factor: 3.075

7.  Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series.

Authors:  Ji-Hyo Hwang; Sang-Min Kim; Kwang-Jun Oh; Yeesuk Kim
Journal:  Int Orthop       Date:  2017-10-07       Impact factor: 3.075

8.  Dual mobility cups for total hip arthroplasty: tips and tricks.

Authors:  Thomas Neri; Bertrand Boyer; Cécile Batailler; Antonio Klasan; Sebastien Lustig; Remi Philippot; Frederic Farizon
Journal:  SICOT J       Date:  2020-06-17

9.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

10.  Postero-posterolateral approach in total hip arthroplasty.

Authors:  Mokrane Ait Mokhtar
Journal:  Int Orthop       Date:  2020-07-17       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.