Literature DB >> 28892988

Treatment of Proximal Humerus Fractures using PHILOS Plate.

Chintan Doshi1, Gaurav Mahesh Sharma2, Lokesh Gudda Naik2, Krishna Sudhakar Badgire2, Faisal Qureshi2.   

Abstract

INTRODUCTION: Treatment of proximal humerus fractures always holds a dilemma for the treating surgeon. AIM: To assess the functional outcome of proximal humerus fractures treated with Proximal Humerus Internal Locking System (PHILOS) plating.
MATERIAL AND METHODS: Fifty three consecutive patients were treated with PHILOS plating between August 2013 and August 2014. The inclusion criteria were skeletally matured patients with closed fracture proximal humerus with displacement >1 cm and varus angulation of >450. Severely comminuted fractures, open fractures and valgus impacted fractures were excluded from the study. The outcome was assessed using Neer's scoring system.
RESULTS: The average age was 54.3±5.8 years. As per the Neers classification system, there were 6 (11.32%) 1-part, 19 (35.85%) 2-part, 17 (32.085) and 11 (20.75%) 3 and 4-part fracture respectively. Average surgical duration was 94±10.2 minutes. Radiological union was seen at 12±4.6 weeks. There were 2 (3.77%) cases of varus collapse. Three (5.66%) cases had screw back out, which was later revised and had a favourable outcome. As per the Neer's scoring system, 7 (13.21%) cases had excellent results, 37 (69.81%) had satisfactory, 6 (11.32%) had unsatisfactory while 3 (05.66%) cases had poor outcomes.
CONCLUSION: PHILOS plating has a good functional outcome. However, proper patient selection, thorough knowledge of the anatomy and biomechanical principles are the pre-requisites for a successful surgery.

Entities:  

Keywords:  Fractures closed; Neer’s scoring system; Shoulder fractures

Year:  2017        PMID: 28892988      PMCID: PMC5583799          DOI: 10.7860/JCDR/2017/26782.10304

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  22 in total

1.  Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus.

Authors:  A J Wijgman; W Roolker; T W Patt; E L F B Raaymakers; R K Marti
Journal:  J Bone Joint Surg Am       Date:  2002-11       Impact factor: 5.284

2.  Internal fixation of fractures of the proximal humerus with the MultiLoc nail.

Authors:  M H Hessmann; S Nijs; T Mittlmeier; M Kloub; M J M Segers; V Winkelbach; M Blauth
Journal:  Oper Orthop Traumatol       Date:  2012-09       Impact factor: 1.154

3.  The importance of medial support in locked plating of proximal humerus fractures.

Authors:  Michael J Gardner; Yoram Weil; Joseph U Barker; Bryan T Kelly; David L Helfet; Dean G Lorich
Journal:  J Orthop Trauma       Date:  2007-03       Impact factor: 2.512

4.  Outcome Analysis of Locking Plate Fixation in Proximal Humerus Fracture.

Authors:  Mayank Vijayvargiya; Abhishek Pathak; Sanjiv Gaur
Journal:  J Clin Diagn Res       Date:  2016-08-01

5.  Locking plate fixation for proximal humerus fractures: a comparison with other fixation techniques.

Authors:  Darin M Friess; Albert Attia
Journal:  Orthopedics       Date:  2008-12       Impact factor: 1.390

6.  Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study.

Authors:  N Südkamp; J Bayer; P Hepp; C Voigt; H Oestern; M Kääb; C Luo; M Plecko; K Wendt; W Köstler; G Konrad
Journal:  J Bone Joint Surg Am       Date:  2009-06       Impact factor: 5.284

7.  Non-operative treatment of comminuted fractures of the proximal humerus in elderly patients.

Authors:  K Zyto
Journal:  Injury       Date:  1998-06       Impact factor: 2.586

8.  Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected].

Authors:  Kevin C Owsley; John T Gorczyca
Journal:  J Bone Joint Surg Am       Date:  2008-02       Impact factor: 5.284

9.  A new osteosynthesis device for the treatment of proximal humerus fractures. Description of the technique and preliminary results.

Authors:  Raffaele Russo; Luigi Vernaglia Lombardi; Michele Ciccarelli; Gerardo Giudice; Fabio Cautiero
Journal:  Chir Organi Mov       Date:  2008-02-10

10.  Internal fixation of proximal humeral fractures with locking proximal humeral plate (LPHP) in elderly patients with osteoporosis.

Authors:  Ramchander Siwach; Roop Singh; Rajesh Kumar Rohilla; Virender Singh Kadian; Sukhbir Singh Sangwan; Manjeet Dhanda
Journal:  J Orthop Traumatol       Date:  2008-07-16
View more
  3 in total

1.  Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study.

Authors:  Xiong Chen; Zheng-Xi Yu; Huai-Yun Wang; Feng Shen; Guo-Bing Lin; Sheng Wang; Zong-Sheng Yin
Journal:  Medicine (Baltimore)       Date:  2019-04       Impact factor: 1.817

2.  Open Reduction and Internal Fixation of Posterior Fracture Dislocation of the Shoulder Made Easy!

Authors:  Waqar Saadat; Puneet Monga
Journal:  J Orthop Case Rep       Date:  2017 Nov-Dec

3.  Influence of Medial Support Screws on the Maintenance of Fracture Reduction after Locked Plating of Proximal Humerus Fractures.

Authors:  Lang-Qing Zeng; Lu-Lu Zeng; Yu-Wen Jiang; Hai-Feng Wei; Wen Zhang; Yun-Feng Chen
Journal:  Chin Med J (Engl)       Date:  2018-08-05       Impact factor: 2.628