Literature DB >> 28885153

Thee-Dimensional Single-Track-Location Shear Wave Elasticity Imaging.

Peter Hollender, Samantha L Lipman, Gregg E Trahey.   

Abstract

Conventional multiple-track-location shear wave elasticity imaging (MTL-SWEI) is a powerful tool for noninvasively estimating tissue elasticity. The resolution and noise levels of MTL-SWEI systems, however, are limited by ultrasound speckle. Single-track-location SWEI (STL-SWEI) is a novel variant which fixes the position of the tracking beam and modulates the push location to effectively cancel out the effects of speckle-induced bias. We present here a 3-D STL-SWEI system, which provides full suppression of lateral and elevation speckle bias for high-resolution volumetric elasticity imaging, and requires no spatial smoothing to make accurate measurements of shear wave speed. We demonstrate and analyze the system's performance in homogeneous and layered elasticity phantoms.

Entities:  

Mesh:

Year:  2017        PMID: 28885153      PMCID: PMC5767318          DOI: 10.1109/TUFFC.2017.2749566

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  25 in total

1.  Spatio-temporal directional filtering for improved inversion of MR elastography images.

Authors:  A Manduca; D S Lake; S A Kruse; R L Ehman
Journal:  Med Image Anal       Date:  2003-12       Impact factor: 8.545

2.  On the effects of reflected waves in transient shear wave elastography.

Authors:  Thomas Deffieux; Jean-Luc Gennisson; Jeremy Bercoff; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-10       Impact factor: 2.725

3.  4-D ultrafast shear-wave imaging.

Authors:  Jean-Luc Gennisson; Jean Provost; Thomas Deffieux; Clément Papadacci; Marion Imbault; Mathieu Pernot; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-06       Impact factor: 2.725

4.  Magnetic resonance elastography: non-invasive mapping of tissue elasticity.

Authors:  A Manduca; T E Oliphant; M A Dresner; J L Mahowald; S A Kruse; E Amromin; J P Felmlee; J F Greenleaf; R L Ehman
Journal:  Med Image Anal       Date:  2001-12       Impact factor: 8.545

5.  On the precision of time-of-flight shear wave speed estimation in homogeneous soft solids: initial results using a matrix array transducer.

Authors:  Michael Wang; Brett Byram; Mark Palmeri; Ned Rouze; Kathryn Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-04       Impact factor: 2.725

6.  Parameters affecting the resolution and accuracy of 2-D quantitative shear wave images.

Authors:  Ned C Rouze; Michael H Wang; Mark L Palmeri; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-08       Impact factor: 2.725

7.  Single tracking location methods suppress speckle noise in shear wave velocity estimation.

Authors:  Etana C Elegbe; Stephen A McAleavey
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

8.  Shearwave dispersion ultrasound vibrometry (SDUV) on swine kidney.

Authors:  Carolina Amador; Matthew W Urban; Shigao Chen; James F Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-12       Impact factor: 2.725

9.  Shear wave arrival time estimates correlate with local speckle pattern.

Authors:  Stephen A Mcaleavey; Laurentius O Osapoetra; Jonathan Langdon
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-12       Impact factor: 2.725

10.  Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging.

Authors:  Mickael Tanter; Jeremy Bercoff; Alexandra Athanasiou; Thomas Deffieux; Jean-Luc Gennisson; Gabriel Montaldo; Marie Muller; Anne Tardivon; Mathias Fink
Journal:  Ultrasound Med Biol       Date:  2008-04-08       Impact factor: 2.998

View more
  4 in total

1.  Parallel Receive Beamforming Improves the Performance of Focused Transmit-Based Single-Track Location Shear Wave Elastography.

Authors:  Rifat Ahmed; Marvin M Doyley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-01       Impact factor: 2.725

Review 2.  Production of acoustic radiation force using ultrasound: methods and applications.

Authors:  Matthew W Urban
Journal:  Expert Rev Med Devices       Date:  2018-10-31       Impact factor: 3.166

3.  Preclinical Imaging Using Single Track Location Shear Wave Elastography: Monitoring the Progression of Murine Pancreatic Tumor Liver Metastasis In Vivo.

Authors:  Rifat Ahmed; Jian Ye; Scott A Gerber; David C Linehan; Marvin M Doyley
Journal:  IEEE Trans Med Imaging       Date:  2020-02-03       Impact factor: 10.048

4.  Plane-Wave Imaging Improves Single-Track Location Shear Wave Elasticity Imaging.

Authors:  Rifat Ahmed; Scott A Gerber; Stephen A McAleavey; Giovanni Schifitto; Marvin M Doyley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06-01       Impact factor: 2.725

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.