Parallel Receive Beamforming Improves the Performance of Focused Transmit-Based Single-Track Location Shear Wave Elastography.

Rifat Ahmed, Marvin M Doyley.   

Abstract

Single-track location shear wave elastography (STL-SWEI) is robust against speckle-induced noise in shear wave speed (SWS) estimates; however, it is not immune to other incoherent sources of noise (such as electronic noise) that increases the variance in SWS estimates. Although estimation averaging enabled by parallel receive beamforming adequately suppresses these noise sources, these beamforming techniques often rely on broad transmit beams (plane or diverging). While broad beam approaches, such as plane-wave imaging, are becoming ubiquitous in research ultrasound systems, clinical systems usually employ focused transmit beams due to compatibility with hardware beamforming and deeper penetration. Consequently, improving the noise robustness of focused transmit-based STL-SWEI may enable easier translation to clinical scenarios. In this article, we experimentally evaluated the performance of parallel beamforming for STL-SWEI using fixed or multiple transmit focus. By imaging tissue-mimicking phantoms, we found that parallel beamforming improved the focal zone elastographic signal-to-noise ratio (SNRe) by 40.9%. For a receive line spacing equivalent to transducer pitch, averaging estimates from three parallel lines produced peak SNRe at the focal zone (25 mm), while, at the shallower regions (< 20 mm), a larger number of parallel lines (>7) were needed. Increasing the beamforming line density by a factor of 8 increased the focal zone SNRe only by 13.2%. When SWS quantification was desirable at a fixed depth (such as within the push focal depth), using a deeper tracking focal zone enabled higher parallel line count and improved the peak SNRe by 33%. The multifocusing strategy produced a lower SNRe than the single-focus configurations. For a fixed tracking focal zone, a depth-dependent averaging based on the simulated transmit intensity adequately accounted for the transmit beamwidth. The results in this work demonstrated that STL-SWEI can be implemented using focused transmit beams with robust noise-suppression capability.

Entities:  

Mesh:

Year:  2020        PMID: 32746171      PMCID: PMC7590368          DOI: 10.1109/TUFFC.2020.2998979

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  23 in total

1.  Shear-wave generation using acoustic radiation force: in vivo and ex vivo results.

Authors:  Kathryn Nightingale; Stephen McAleavey; Gregg Trahey
Journal:  Ultrasound Med Biol       Date:  2003-12       Impact factor: 2.998

2.  Supersonic shear imaging: a new technique for soft tissue elasticity mapping.

Authors:  Jérémy Bercoff; Mickaël Tanter; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-04       Impact factor: 2.725

Review 3.  WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 2: breast.

Authors:  Richard G Barr; Kazutaka Nakashima; Dominique Amy; David Cosgrove; Andre Farrokh; Fritz Schafer; Jeffrey C Bamber; Laurent Castera; Byung Ihn Choi; Yi-Hong Chou; Christoph F Dietrich; Hong Ding; Giovanna Ferraioli; Carlo Filice; Mireen Friedrich-Rust; Timothy J Hall; Kathryn R Nightingale; Mark L Palmeri; Tsuyoshi Shiina; Shinichi Suzuki; Ioan Sporea; Stephanie Wilson; Masatoshi Kudo
Journal:  Ultrasound Med Biol       Date:  2015-03-18       Impact factor: 2.998

4.  Single- and multiple-track-location shear wave and acoustic radiation force impulse imaging: matched comparison of contrast, contrast-to-noise ratio and resolution.

Authors:  Peter J Hollender; Stephen J Rosenzweig; Kathryn R Nightingale; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2015-02-17       Impact factor: 2.998

5.  Analysis of Transient Shear Wave in Lossy Media.

Authors:  Kevin J Parker; Juvenal Ormachea; Scott Will; Zaegyoo Hah
Journal:  Ultrasound Med Biol       Date:  2018-04-26       Impact factor: 2.998

6.  Recovery of the Complete Data Set From Focused Transmit Beams.

Authors:  Nick Bottenus
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-01       Impact factor: 2.725

7.  WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: liver.

Authors:  Giovanna Ferraioli; Carlo Filice; Laurent Castera; Byung Ihn Choi; Ioan Sporea; Stephanie R Wilson; David Cosgrove; Christoph F Dietrich; Dominique Amy; Jeffrey C Bamber; Richard Barr; Yi-Hong Chou; Hong Ding; Andre Farrokh; Mireen Friedrich-Rust; Timothy J Hall; Kazutaka Nakashima; Kathryn R Nightingale; Mark L Palmeri; Fritz Schafer; Tsuyoshi Shiina; Shinichi Suzuki; Masatoshi Kudo
Journal:  Ultrasound Med Biol       Date:  2015-03-20       Impact factor: 2.998

8.  Evaluation of ultrasound synthetic aperture imaging using bidirectional pixel-based focusing: preliminary phantom and in vivo breast study.

Authors:  Choye Kim; Changhan Yoon; Jong-Ho Park; Yuhwa Lee; Won Hwa Kim; Jung Min Chang; Byung Ihn Choi; Tai-Kyong Song; Yang-Mo Yoo
Journal:  IEEE Trans Biomed Eng       Date:  2013-05-15       Impact factor: 4.538

9.  Shear wave arrival time estimates correlate with local speckle pattern.

Authors:  Stephen A Mcaleavey; Laurentius O Osapoetra; Jonathan Langdon
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-12       Impact factor: 2.725

10.  Ultrasound Open Platforms for Next-Generation Imaging Technique Development.

Authors:  Enrico Boni; Alfred C H Yu; Steven Freear; Jorgen Arendt Jensen; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.