Literature DB >> 22899119

Parameters affecting the resolution and accuracy of 2-D quantitative shear wave images.

Ned C Rouze1, Michael H Wang, Mark L Palmeri, Kathryn R Nightingale.   

Abstract

Time-of-flight methods allow quantitative measurement of shear wave speed (SWS) from ultrasonically tracked displacements following impulsive acoustic radiation force excitation in tissue. In heterogeneous materials, reflections at boundaries can distort the wave shape and confound determination of the wave arrival time. The magnitude of these effects depends on the shear wavelength of the excitation, the kernel size used to calculate the SWS, and the method used to determine the wave arrival time. In this study, we perform a parametric analysis of these factors using finite element modeling of the tissue response and simulated ultrasonic tracking. Two geometries are used, a stiff vertical layer and a stiff spherical inclusion, each in a uniform background. Wave arrival times are estimated using the peak displacement, peak slope of the leading edge, and cross-correlation methods. Results are evaluated in terms of reconstruction accuracy, resolution, contrast, and contrast-to-noise ratio of reconstructed SWS images. Superior results are obtained using narrower excitation widths and arrival time estimators which identify the leading edge of the propagating wave. The optimal kernel size is determined by a tradeoff between improved accuracy for larger kernels at the expense of spatial resolution.

Entities:  

Mesh:

Year:  2012        PMID: 22899119      PMCID: PMC3425955          DOI: 10.1109/TUFFC.2012.2377

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  19 in total

1.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics.

Authors:  A P Sarvazyan; O V Rudenko; S D Swanson; J B Fowlkes; S Y Emelianov
Journal:  Ultrasound Med Biol       Date:  1998-11       Impact factor: 2.998

2.  On the feasibility of remote palpation using acoustic radiation force.

Authors:  K R Nightingale; M L Palmeri; R W Nightingale; G E Trahey
Journal:  J Acoust Soc Am       Date:  2001-07       Impact factor: 1.840

3.  Spatio-temporal directional filtering for improved inversion of MR elastography images.

Authors:  A Manduca; D S Lake; S A Kruse; R L Ehman
Journal:  Med Image Anal       Date:  2003-12       Impact factor: 8.545

4.  Shear-wave generation using acoustic radiation force: in vivo and ex vivo results.

Authors:  Kathryn Nightingale; Stephen McAleavey; Gregg Trahey
Journal:  Ultrasound Med Biol       Date:  2003-12       Impact factor: 2.998

5.  Supersonic shear imaging: a new technique for soft tissue elasticity mapping.

Authors:  Jérémy Bercoff; Mickaël Tanter; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-04       Impact factor: 2.725

6.  Quantifying elasticity and viscosity from measurement of shear wave speed dispersion.

Authors:  Shigao Chen; Mostafa Fatemi; James F Greenleaf
Journal:  J Acoust Soc Am       Date:  2004-06       Impact factor: 1.840

7.  A finite-element method model of soft tissue response to impulsive acoustic radiation force.

Authors:  Mark L Palmeri; Amy C Sharma; Richard R Bouchard; Roger W Nightingale; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-10       Impact factor: 2.725

8.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

9.  Robust estimation of time-of-flight shear wave speed using a radon sum transformation.

Authors:  Ned C Rouze; Michael H Wang; Mark L Palmeri; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-12       Impact factor: 2.725

10.  Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging.

Authors:  Mickael Tanter; Jeremy Bercoff; Alexandra Athanasiou; Thomas Deffieux; Jean-Luc Gennisson; Gabriel Montaldo; Marie Muller; Anne Tardivon; Mathias Fink
Journal:  Ultrasound Med Biol       Date:  2008-04-08       Impact factor: 2.998

View more
  38 in total

1.  A multiresolution approach to shear wave image reconstruction.

Authors:  Peter Hollender; Nick Bottenus; Gregg Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-08       Impact factor: 2.725

2.  Robust Short-Lag Spatial Coherence Imaging of Breast Ultrasound Data: Initial Clinical Results.

Authors:  Alycen Wiacek; Ole Marius Hoel Rindal; Eniola Falomo; Kelly Myers; Kelly Fabrega-Foster; Susan Harvey; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-27       Impact factor: 2.725

3.  Evaluation of Reconstruction Parameters for 2-D Comb-Push Ultrasound Shear Wave Elastography.

Authors:  Jorge Racedo; Matthew W Urban
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-30       Impact factor: 2.725

4.  Dual-Phase Transmit Focusing for Multiangle Compound Shear-Wave Elasticity Imaging.

Authors:  Heechul Yoon; Salavat R Aglyamov; Stanislav Y Emelianov
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-07-11       Impact factor: 2.725

5.  High-resolution harmonic motion imaging (HR-HMI) for tissue biomechanical property characterization.

Authors:  Teng Ma; Xuejun Qian; Chi Tat Chiu; Mingyue Yu; Hayong Jung; Yao-Sheng Tung; K Kirk Shung; Qifa Zhou
Journal:  Quant Imaging Med Surg       Date:  2015-02

6.  Comb-push ultrasound shear elastography (CUSE) with various ultrasound push beams.

Authors:  Pengfei Song; Matthew W Urban; Armando Manduca; Heng Zhao; James F Greenleaf; Shigao Chen
Journal:  IEEE Trans Med Imaging       Date:  2013-04-12       Impact factor: 10.048

7.  Contrast in intracardiac acoustic radiation force impulse images of radiofrequency ablation lesions.

Authors:  Stephanie A Eyerly; Tristram D Bahnson; Jason I Koontz; David P Bradway; Douglas M Dumont; Gregg E Trahey; Patrick D Wolf
Journal:  Ultrason Imaging       Date:  2014-04       Impact factor: 1.578

8.  High-resolution acoustic-radiation-force-impulse imaging for assessing corneal sclerosis.

Authors:  Cho-Chiang Shih; Chih-Chung Huang; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Med Imaging       Date:  2013-04-08       Impact factor: 10.048

Review 9.  Production of acoustic radiation force using ultrasound: methods and applications.

Authors:  Matthew W Urban
Journal:  Expert Rev Med Devices       Date:  2018-10-31       Impact factor: 3.166

10.  Acoustic radiation force beam sequence performance for detection and material characterization of atherosclerotic plaques: preclinical, ex vivo results.

Authors:  Russell H Behler; Tomasz J Czernuszewicz; Chih-Da Wu; Timothy C Nichols; Hongtu Zhu; Jonathon W Homeister; Elizabeth P Merricks; Caterina M Gallippi
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-12       Impact factor: 2.725

View more