Literature DB >> 26670847

Shear wave arrival time estimates correlate with local speckle pattern.

Stephen A Mcaleavey, Laurentius O Osapoetra, Jonathan Langdon.   

Abstract

We present simulation and phantom studies demonstrating a strong correlation between errors in shear wave arrival time estimates and the lateral position of the local speckle pattern in targets with fully developed speckle. We hypothesize that the observed arrival time variations are largely due to the underlying speckle pattern, and call the effect speckle bias. Arrival time estimation is a key step in quantitative shear wave elastography, performed by tracking tissue motion via cross-correlation of RF ultrasound echoes or similar methods. Variations in scatterer strength and interference of echoes from scatterers within the tracking beam result in an echo that does not necessarily describe the average motion within the beam, but one favoring areas of constructive interference and strong scattering. A swept-receive image, formed by fixing the transmit beam and sweeping the receive aperture over the region of interest, is used to estimate the local speckle pattern. Metrics for the lateral position of the speckle are found to correlate strongly (r > 0.7) with the estimated shear wave arrival times both in simulations and in phantoms. Lateral weighting of the swept-receive pattern improved the correlation between arrival time estimates and speckle position. The simulations indicate that high RF echo correlation does not equate to an accurate shear wave arrival time estimate-a high correlation coefficient indicates that motion is being tracked with high precision, but the location tracked is uncertain within the tracking beam width. The presence of a strong on-axis speckle is seen to imply high RF correlation and low bias. The converse does not appear to be true-highly correlated RF echoes can still produce biased arrival time estimates. The shear wave arrival time bias is relatively stable with variations in shear wave amplitude and sign (-20 μm to 20 μm simulated) compared with the variation with different speckle realizations obtained along a given tracking vector. We show that the arrival time bias is weakly dependent on shear wave amplitude compared with the variation with axial position/ local speckle pattern. Apertures of f/3 to f/8 on transmit and f/2 and f/4 on receive were simulated. Arrival time error and correlation with speckle pattern are most strongly determined by the receive aperture.

Entities:  

Mesh:

Year:  2015        PMID: 26670847      PMCID: PMC4721527          DOI: 10.1109/TUFFC.2015.007171

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  27 in total

1.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics.

Authors:  A P Sarvazyan; O V Rudenko; S D Swanson; J B Fowlkes; S Y Emelianov
Journal:  Ultrasound Med Biol       Date:  1998-11       Impact factor: 2.998

2.  On the feasibility of remote palpation using acoustic radiation force.

Authors:  K R Nightingale; M L Palmeri; R W Nightingale; G E Trahey
Journal:  J Acoust Soc Am       Date:  2001-07       Impact factor: 1.840

Review 3.  Selected methods for imaging elastic properties of biological tissues.

Authors:  James F Greenleaf; Mostafa Fatemi; Michael Insana
Journal:  Annu Rev Biomed Eng       Date:  2003-04-10       Impact factor: 9.590

4.  Linear system models for ultrasonic imaging: application to signal statistics.

Authors:  Roger J Zemp; Craig K Abbey; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-06       Impact factor: 2.725

5.  2-D companding for noise reduction in strain imaging.

Authors:  P Chaturvedi; M F Insana; T J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

6.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

7.  Harmonic pulsed excitation and motion detection of a vibrating reflective target.

Authors:  Matthew W Urban; James F Greenleaf
Journal:  J Acoust Soc Am       Date:  2008-01       Impact factor: 1.840

8.  Noninvasive evaluation of hepatic fibrosis using acoustic radiation force-based shear stiffness in patients with nonalcoholic fatty liver disease.

Authors:  Mark L Palmeri; Michael H Wang; Ned C Rouze; Manal F Abdelmalek; Cynthia D Guy; Barry Moser; Anna Mae Diehl; Kathryn R Nightingale
Journal:  J Hepatol       Date:  2011-01-21       Impact factor: 25.083

9.  Variance and covariance of accumulated displacement estimates.

Authors:  Matthew Bayer; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

10.  Single tracking location methods suppress speckle noise in shear wave velocity estimation.

Authors:  Etana C Elegbe; Stephen A McAleavey
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

View more
  10 in total

1.  Evaluation of Reconstruction Parameters for 2-D Comb-Push Ultrasound Shear Wave Elastography.

Authors:  Jorge Racedo; Matthew W Urban
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-30       Impact factor: 2.725

2.  Assessment of Structural Heterogeneity and Viscosity in the Cervix Using Shear Wave Elasticity Imaging: Initial Results from a Rhesus Macaque Model.

Authors:  Ivan M Rosado-Mendez; Mark L Palmeri; Lindsey C Drehfal; Quinton W Guerrero; Heather Simmons; Helen Feltovich; Timothy J Hall
Journal:  Ultrasound Med Biol       Date:  2017-02-08       Impact factor: 2.998

3.  Parallel Receive Beamforming Improves the Performance of Focused Transmit-Based Single-Track Location Shear Wave Elastography.

Authors:  Rifat Ahmed; Marvin M Doyley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-01       Impact factor: 2.725

4.  Fourier-Domain Shift Matching: A Robust Time-of-Flight Approach for Shear Wave Speed Estimation.

Authors:  David Rosen; Jingfeng Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-05       Impact factor: 2.725

5.  Single tracking location acoustic radiation force impulse viscoelasticity estimation (STL-VE): A method for measuring tissue viscoelastic parameters.

Authors:  Jonathan H Langdon; Etana Elegbe; Stephen A McAleavey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-07       Impact factor: 2.725

6.  Preclinical Imaging Using Single Track Location Shear Wave Elastography: Monitoring the Progression of Murine Pancreatic Tumor Liver Metastasis In Vivo.

Authors:  Rifat Ahmed; Jian Ye; Scott A Gerber; David C Linehan; Marvin M Doyley
Journal:  IEEE Trans Med Imaging       Date:  2020-02-03       Impact factor: 10.048

7.  On System-Dependent Sources of Uncertainty and Bias in Ultrasonic Quantitative Shear-Wave Imaging.

Authors:  Yufeng Deng; Ned C Rouze; Mark L Palmeri; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-02-08       Impact factor: 2.725

8.  Thee-Dimensional Single-Track-Location Shear Wave Elasticity Imaging.

Authors:  Peter Hollender; Samantha L Lipman; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-09-06       Impact factor: 2.725

9.  Plane-Wave Imaging Improves Single-Track Location Shear Wave Elasticity Imaging.

Authors:  Rifat Ahmed; Scott A Gerber; Stephen A McAleavey; Giovanni Schifitto; Marvin M Doyley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06-01       Impact factor: 2.725

10.  In silico simulation of liver crack detection using ultrasonic shear wave imaging.

Authors:  Erwei Nie; Jiao Yu; Debaditya Dutta; Yanying Zhu
Journal:  BMC Med Imaging       Date:  2018-05-16       Impact factor: 1.930

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.