Literature DB >> 14561551

Spatio-temporal directional filtering for improved inversion of MR elastography images.

A Manduca1, D S Lake, S A Kruse, R L Ehman.   

Abstract

Dynamic magnetic resonance elastography can visualize and measure propagating shear waves in tissue-like materials subjected to harmonic mechanical excitation. This allows the calculation of local values of material parameters such as shear modulus and attenuation. Various inversion algorithms to perform such calculations have been proposed, but they are sensitive to areas of low displacement amplitude (and hence low SNR) that result from interference patterns due to reflection and refraction. A spatio-temporal directional filter applied as a pre-processing step can separate interfering waves so they can be processed separately. Weighted combinations of inversions from such directionally separated data sets can significantly improve reconstructions of shear modulus and attenuation.

Mesh:

Year:  2003        PMID: 14561551     DOI: 10.1016/s1361-8415(03)00038-0

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  113 in total

1.  Neuropilin-1 stimulates tumor growth by increasing fibronectin fibril assembly in the tumor microenvironment.

Authors:  Usman Yaqoob; Sheng Cao; Uday Shergill; Kumaravelu Jagavelu; Zhimin Geng; Meng Yin; Thiago M de Assuncao; Ying Cao; Anna Szabolcs; Snorri Thorgeirsson; Martin Schwartz; Ju Dong Yang; Richard Ehman; Lewis Roberts; Debabrata Mukhopadhyay; Vijay H Shah
Journal:  Cancer Res       Date:  2012-06-27       Impact factor: 12.701

2.  Shear wave speed recovery in sonoelastography using crawling wave data.

Authors:  Kui Lin; Joyce McLaughlin; Daniel Renzi; Ashley Thomas
Journal:  J Acoust Soc Am       Date:  2010-07       Impact factor: 1.840

3.  Magnetic Resonance Elastography.

Authors:  Daniel V Litwiller; Yogesh K Mariappan; Richard L Ehman
Journal:  Curr Med Imaging Rev       Date:  2012

4.  A multiresolution approach to shear wave image reconstruction.

Authors:  Peter Hollender; Nick Bottenus; Gregg Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-08       Impact factor: 2.725

5.  Evaluation of Reconstruction Parameters for 2-D Comb-Push Ultrasound Shear Wave Elastography.

Authors:  Jorge Racedo; Matthew W Urban
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-30       Impact factor: 2.725

Review 6.  Magnetic resonance elastography of abdomen.

Authors:  Sudhakar Kundapur Venkatesh; Richard L Ehman
Journal:  Abdom Imaging       Date:  2015-04

7.  Feasibility of using magnetic resonance elastography to study the effect of aging on shear modulus of skeletal muscle.

Authors:  Zachary J Domire; Matthew B McCullough; Qingshan Chen; Kai-Nan An
Journal:  J Appl Biomech       Date:  2009-02       Impact factor: 1.833

Review 8.  Abdominal magnetic resonance elastography.

Authors:  Meng Yin; Jun Chen; Kevin J Glaser; Jayant A Talwalkar; Richard L Ehman
Journal:  Top Magn Reson Imaging       Date:  2009-04

Review 9.  Magnetic resonance elastography of liver: technique, analysis, and clinical applications.

Authors:  Sudhakar K Venkatesh; Meng Yin; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2013-03       Impact factor: 4.813

10.  In vivo quantification of myocardial stiffness in hypertensive porcine hearts using MR elastography.

Authors:  Ria Mazumder; Samuel Schroeder; Xiaokui Mo; Bradley D Clymer; Richard D White; Arunark Kolipaka
Journal:  J Magn Reson Imaging       Date:  2016-08-26       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.