Literature DB >> 28861693

Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale.

Golafsoun Ameri1, John S H Baxter2, Daniel Bainbridge3, Terry M Peters2, Elvis C S Chen2.   

Abstract

PURPOSE: Real-time ultrasound has become a crucial aspect of several image-guided interventions. One of the main constraints of such an approach is the difficulty in interpretability of the limited field of view of the image, a problem that has recently been addressed using mixed reality, such as augmented reality and augmented virtuality. The growing popularity and maturity of mixed reality has led to a series of informal guidelines to direct development of new systems and to facilitate regulatory approval. However, the goals of mixed reality image guidance systems and the guidelines for their development have not been thoroughly discussed. The purpose of this paper is to identify and critically examine development guidelines in the context of a mixed reality ultrasound guidance system through a case study.
METHODS: A mixed reality ultrasound guidance system tailored to central line insertions was developed in close collaboration with an expert user. This system outperformed ultrasound-only guidance in a novice user study and has obtained clearance for clinical use in humans. A phantom study with 25 experienced physicians was carried out to compare the performance of the mixed reality ultrasound system against conventional ultrasound-only guidance. Despite the previous promising results, there was no statistically significant difference between the two systems.
RESULTS: Guidelines for developing mixed reality image guidance systems cannot be applied indiscriminately. Each design decision, no matter how well justified, should be the subject of scientific and technical investigation. Iterative and small-scale evaluation can readily unearth issues and previously unknown or implicit system requirements.
CONCLUSIONS: We recommend a wary eye in development of mixed reality ultrasound image guidance systems emphasizing small-scale iterative evaluation alongside system development. Ultimately, we recommend that the image-guided intervention community furthers and deepens this discussion into best practices in developing image-guided interventions.

Entities:  

Keywords:  Augmented reality; Augmented virtuality; Central line; Guidelines; Internal jugular vein catheterization; Mixed reality; System development; Ultrasound guidance

Mesh:

Year:  2017        PMID: 28861693     DOI: 10.1007/s11548-017-1665-7

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  30 in total

Review 1.  Preventing complications of central venous catheterization.

Authors:  David C McGee; Michael K Gould
Journal:  N Engl J Med       Date:  2003-03-20       Impact factor: 91.245

2.  Prostate biopsy assistance system with gland deformation estimation for enhanced precision.

Authors:  Michael Baumann; Pierre Mozer; Vincent Daanen; Jocelyne Troccaz
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

Review 3.  3D echocardiography: a review of the current status and future directions.

Authors:  Judy Hung; Roberto Lang; Frank Flachskampf; Stanton K Shernan; Marti L McCulloch; David B Adams; James Thomas; Mani Vannan; Thomas Ryan
Journal:  J Am Soc Echocardiogr       Date:  2007-03       Impact factor: 5.251

4.  First human experience with real-time integration of intracardiac echocardiography and 3D electroanatomical imaging to guide right free wall accessory pathway ablation.

Authors:  Yaariv Khaykin; Ofer Klemm; Atul Verma
Journal:  Europace       Date:  2007-11-13       Impact factor: 5.214

5.  Value of augmented reality-enhanced transesophageal echocardiography (TEE) for determining optimal annuloplasty ring size during mitral valve repair.

Authors:  Joerg Ender; Jasmina Koncar-Zeh; Chirojit Mukherjee; Stephan Jacobs; Michael A Borger; Christoph Viola; Michael Gessat; Jens Fassl; Friedrich W Mohr; Volkmar Falk
Journal:  Ann Thorac Surg       Date:  2008-11       Impact factor: 4.330

6.  Central venous catheter care for the patients with cancer: ultrasound-guided insertion should be strongly recommended for internal jugular vein catheterization.

Authors:  L Cavanna; G Civardi; P Mordenti; D Vallisa; R Bertè; C Di Nunzio
Journal:  Ann Oncol       Date:  2013-10-07       Impact factor: 32.976

Review 7.  Ultrasound-guided vascular access: a comprehensive review.

Authors:  Menachem M Weiner; Paul Geldard; Alexander J C Mittnacht
Journal:  J Cardiothorac Vasc Anesth       Date:  2012-09-18       Impact factor: 2.628

8.  Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging.

Authors:  K J M Surry; H J B Austin; A Fenster; T M Peters
Journal:  Phys Med Biol       Date:  2004-12-21       Impact factor: 3.609

9.  A navigation platform for guidance of beating heart transapical mitral valve repair.

Authors:  John T Moore; Michael W A Chu; Bob Kiaii; Daniel Bainbridge; Gerard Guiraudon; Chris Wedlake; Maria Currie; Martin Rajchl; Rajni V Patel; Terry M Peters
Journal:  IEEE Trans Biomed Eng       Date:  2012-10-03       Impact factor: 4.538

10.  An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance.

Authors:  Michael Blaivas; Srikar Adhikari
Journal:  Crit Care Med       Date:  2009-08       Impact factor: 7.598

View more
  6 in total

1.  Automatic segmentation of the carotid artery and internal jugular vein from 2D ultrasound images for 3D vascular reconstruction.

Authors:  Leah A Groves; Blake VanBerlo; Natan Veinberg; Abdulrahman Alboog; Terry M Peters; Elvis C S Chen
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-08-24       Impact factor: 2.924

2.  Development of a Head-Mounted Holographic Needle Guidance System for Enhanced Ultrasound-Guided Neuraxial Anesthesia: System Development and Observational Evaluation.

Authors:  Jaya Tanwani; Fahad Alam; Clyde Matava; Stephen Choi; Paul McHardy; Oskar Singer; Geraldine Cheong; Julian Wiegelmann
Journal:  JMIR Form Res       Date:  2022-06-23

3.  A first attempt of inferior vena cava filter successfully guided by a mixed-reality system: a case report.

Authors:  Hang Zhu; Yao Li; Chi Wang; Qiu-Yang Li; Zheng-Yang Xu; Xin Li; Abudureyimu Abudulitipujiang; Ji-Xing Pan; Er-Long Fan; Jun Guo; Yun-Dai Chen
Journal:  J Geriatr Cardiol       Date:  2019-07       Impact factor: 3.327

4.  Application of Mixed Reality Using Optical See-Through Head-Mounted Displays in Transforaminal Percutaneous Endoscopic Lumbar Discectomy.

Authors:  Xiaoyang Liu; Jianmin Sun; Meimei Zheng; Xingang Cui
Journal:  Biomed Res Int       Date:  2021-02-16       Impact factor: 3.411

5.  Mixed-Reality-Assisted Puncture of the Common Femoral Artery in a Phantom Model.

Authors:  Christian Uhl; Johannes Hatzl; Katrin Meisenbacher; Lea Zimmer; Niklas Hartmann; Dittmar Böckler
Journal:  J Imaging       Date:  2022-02-16

6.  Towards a First-Person Perspective Mixed Reality Guidance System for Needle Interventions.

Authors:  Leah Groves; Natalie Li; Terry M Peters; Elvis C S Chen
Journal:  J Imaging       Date:  2022-01-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.