Literature DB >> 23047858

A navigation platform for guidance of beating heart transapical mitral valve repair.

John T Moore1, Michael W A Chu, Bob Kiaii, Daniel Bainbridge, Gerard Guiraudon, Chris Wedlake, Maria Currie, Martin Rajchl, Rajni V Patel, Terry M Peters.   

Abstract

Traditional surgical approaches for repairing diseased mitral valves (MVs) have relied on placing the patient on cardiopulmonary bypass (on pump), stopping the heart and accessing the arrested heart directly. However, because this approach has the potential for adverse neurological, vascular, and immunological sequelae, less invasive beating heart alternatives are desirable. Emerging beating heart techniques have been developed to offer high-risk patients MV repair using ultrasound guidance alone without stopping the heart. This paper describes the first porcine trials of the NeoChord DS1000 (Minnetonka, MN), employed to attach neochordae to a MV leaflet using the traditional ultrasound-guided protocol augmented by dynamic virtual geometric models. The distance errors of the tracked tool tip from the intended midline trajectory (5.2 ± 2.4 mm versus 16.8 ± 10.9 mm, p = 0.003), navigation times (16.7 ± 8.0 s versus 92.0 ± 84.5 s, p = 0.004), and total path lengths (225.2 ± 120.3 mm versus 1128.9 ± 931.1 mm, p = 0.003) were significantly shorter in the augmented ultrasound compared to navigation with ultrasound alone, indicating a substantial improvement in the safety and simplicity of the procedure.

Entities:  

Mesh:

Year:  2012        PMID: 23047858     DOI: 10.1109/TBME.2012.2222405

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

Review 1.  Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale.

Authors:  Golafsoun Ameri; John S H Baxter; Daniel Bainbridge; Terry M Peters; Elvis C S Chen
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-08-31       Impact factor: 2.924

2.  Navigation guidance for ventricular septal defect closure in heart phantoms.

Authors:  Gerardo Tibamoso-Pedraza; Sarah Amouri; Victor Molina; Iñaki Navarro; Marie-Josée Raboisson; Joaquim Miró; Chantale Lapierre; Sylvie Ratté; Luc Duong
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-07-07       Impact factor: 3.421

3.  On mixed reality environments for minimally invasive therapy guidance: systems architecture, successes and challenges in their implementation from laboratory to clinic.

Authors:  Cristian A Linte; Katherine P Davenport; Kevin Cleary; Craig Peters; Kirby G Vosburgh; Nassir Navab; Philip Eddie Edwards; Pierre Jannin; Terry M Peters; David R Holmes; Richard A Robb
Journal:  Comput Med Imaging Graph       Date:  2013-02-08       Impact factor: 4.790

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.