Literature DB >> 31447896

A first attempt of inferior vena cava filter successfully guided by a mixed-reality system: a case report.

Hang Zhu1, Yao Li1, Chi Wang1, Qiu-Yang Li2, Zheng-Yang Xu3, Xin Li4, Abudureyimu Abudulitipujiang4, Ji-Xing Pan4, Er-Long Fan4, Jun Guo1, Yun-Dai Chen1.   

Abstract

Entities:  

Keywords:  Inferior vena cava filter; Mixed-reality technology; Pulmonary embolism

Year:  2019        PMID: 31447896      PMCID: PMC6689521          DOI: 10.11909/j.issn.1671-5411.2019.07.008

Source DB:  PubMed          Journal:  J Geriatr Cardiol        ISSN: 1671-5411            Impact factor:   3.327


× No keyword cloud information.
Pulmonary embolism (PE) is one of the fatal heart attacks, and lower limbs deep vein thrombosis (DVT) is the most common reason for PE. Inferior vena cava filter (IVCF) implantation is a most prevention for PE. But it may carry a high risk of injury because of the radiation and contrast agent. Patients with nephrotic syndrome (NS) or some other renal diseases may prone to thrombosis due to the excretion of protein C and protein S overmuch. So, it is necessary to develop a new therapy without contrast agent. Mixed-reality (MR) is a new technology as a guidance of inferior vena cava filter implantation exposed under no X-ray and required no contrast agent. We describe a case of old man with NS and PE who can't tolerate traditional interventional surgery to prevent the embolus from falling off. We performed IVCF implantation guided by MR system which was totally suitable for this patient. The patient was a 65-year-old man with NS treated with losartan and Haikun Shenxi Capsule regularly for one year. A month ago, he underwent ultrasound for his right leg swelling and thrombosis was found from right external iliac vein to femoral vein. Then he received treatment with thrombolysis and anticoagulation for lower limb DVT without IVCF implantation due to renal insufficiency in the local hospital. But recently, the patient had recurrence of chest distress and dyspnea with oxygen desaturation. Physical examination showed roughly normal. ECG and Echocardiography didn't show a manifestation of PE or right-ventricular failure. Blood levels of D-dimer were severe elevated. As the patient suffered from NS for one year, we also checked his renal function. Serum creatinine was 63.1 µmol/L but the glomerular filtration rate (eGFR) was just 50.96. Pulmonary artery computed tomography angiography (CTA) showed bilateral pulmonary filling defect and chest CT suggested pulmonary infarction in bilateral inferior lobe. An ultrasound of lower limb vein was reexamined and showed that the thrombosis was still there. In summary, the patient had a history of DVT and thrombolysis treatment, high D-dimer and a typical change in pulmonary artery CTA. The diagnosis of PE was confirmed. So, anticoagulation therapy was continued. However, all the therapy did not work, and if we repeated thrombolysis could result in recurrence of PE. Inferior vena cava filter (IVCF) implantation is a most prevention for recurrence of PE. Though his renal insufficiency mattered, the management of PE was prioritized. But IVCF implantation with contrast agent injection of a patient with renal insufficient is at high risk. We hoped to find a method that can avoid the radiation and contrast agent to head-off risk of contrast-induced nephropathy (CIN) and even acute kidney injury (AKI). MR system can visualize human anatomy without the need for contrast agents. This technique requires only a small dose of contrast agent (about 10 mL) for preoperative CT examination to confirm the position of renal vein opening and no contrast agent during the surgery. Before the operation, a CT three-dimensional (3D) reconstruction depend on DICOM data was performed to model the grid (STL) and then carry out the material setting including color assignments and transparency presets. And the data is output in v3d format (a data transmission format in Weizhuo Zhiyuan technology co., LTD, BeiJing) obtain holographic image data (Figure 1). Then we measured the length of the vascular centerline from the puncture point on the body surface to the preset position of the filter, set markers along the way and make a STL model, and push it to the mixed-reality display device (Figure 2).
Figure 1.

A CT three-dimensional (3D) reconstruction was performed to obtain holographic image data.

Figure 2.

Set markers on the body surface and push the STL model to the MR display device.

During the operation, 3D holographic images of femoral vein, IVC and renal vein of the patient were presented in MR glasses worn by the operators through image fusion and spatial positioning. And the holographic 3D model was fused with the human body in the real surgery in equal proportions. The right femoral vein was punctured under local anesthesia and 6F vascular sheath was inserted. The operators turn on MR glasses, and inserted an elbow wire of temporary IVCF implant set (LifeTech Scientific Corporation) below the renal vein opening, then withdraw the 6F vascular sheath and expanded the skin with the lancet, and inserted the filter delivery sheath. According to the length of the sheath tube from the body surface puncture point into the vessel, the position of the sheath tube would display in real time in MR glasses. We sent the sheath tube to 1–2 cm below the renal vein opening and confirmed the position of the sheath tube was consistent with the preset position by ultrasound, then released the filter. After the removal of the sheath tube, the patient returned to the ward with no complaints of discomfort (Figure 3).
Figure 3.

The MR technology was applied in the surgery.

PE is one of the three most common cardiovascular diseases.[1] DVT is the main cause of PE. Thrombosis that forms in the veins of the lower extremities or the pelvis breaks off and blocks the pulmonary artery and its branches with venous reflux. For this case, the patient recurrent DVT and PE for his history of nephrotic syndrome (NS). As his renal impairment, protein C, protein S and some other procoagulant are excreted overmuch and increased the risk of DVT and PE. For patients with sufficient anticoagulation but recurrent PE, the implantation of IVCF is an important measure to prevent further PE.[2] The tradition IVCF implantation should be performed under X-ray. The position of the renal vein should be confirmed by cephalography of the IVCF and after the completion of placement, cephalography should be performed again. So 30–50 mL contrast agent is needed during the traditional surgery. CIN is one of the major complications of interventional surgery. In the general population, the incidence of CIN is about 2%. However, some studies have shown that renal impairment is the most important risk factor for CIN,[3],[4] and the incidence of CIN increases to 14.8%–55% in patients with pre-contrast renal impairment.[4], [5] In this case, conventional surgical methods undoubtedly greatly increase the risk of CIN for the patient's NS history. Therefore, the application of Mixed-Reality (MR) technology can guide the surgical operations without radiation and contrast agent, which not only avoids the risk of CIN in patients, but also reduces the radiation injury of the patient and surgeons. Although a CT 3D reconstruction with small dose of contrast agent had to be performed before the operation, the risk of CIN and AKI would be much decreased compared with the risks caused by traditional IVC filter implantation. MR is a brand new digital holographic imaging technology, which generate virtual 3D models of patients' imaging information and superimpose them on the real surgery of the operator to achieve the mixture of real human body and digital model, so as to visualize the human anatomical structure on the surface of human body.[6] The greatest advantage of this new technology is that it reduces the error between the actual structure and the operator's range of vision.[7] Through 3D imaging of the interventional vessels, the authenticity and visual effects of the open surgery can still be achieved during the minimally invasive surgery. In addition, it can make surgeons clearer and more accurate about the interventional route and reduce the occurrence and risk of complications. At present, this technology has been effectively applied in surgery such as cancer operations and robot assisted surgery.[8], [9] In the field of cardiovascular intervention, previous studies have shown that MR has good authenticity and reliability in the 3D imaging of subclavian vein.[10] The successful implementation of this operation provides valuable evidences for the application of this technique in the cardiovascular field. In the future, MR is likely to be widely used in medical education, research, remote consultation and military medicine, promoting the development of medicine towards a more efficient and accurate direction.
  10 in total

1.  A mixed-reality part-task trainer for subclavian venous access.

Authors:  Albert R Robinson; Nikolaus Gravenstein; Lou Ann Cooper; David Lizdas; Isaac Luria; Samsun Lampotang
Journal:  Simul Healthc       Date:  2014-02       Impact factor: 1.929

2.  A 3-D mixed-reality system for stereoscopic visualization of medical dataset.

Authors:  Vincenzo Ferrari; Giuseppe Megali; Elena Troia; Andrea Pietrabissa; Franco Mosca
Journal:  IEEE Trans Biomed Eng       Date:  2009-07-31       Impact factor: 4.538

3.  Head-Mounted Mixed-Reality Technology During Robotic-Assisted Transanal Total Mesorectal Excision.

Authors:  Tobias Huber; Edin Hadzijusufovic; Christian Hansen; Markus Paschold; Hauke Lang; Werner Kneist
Journal:  Dis Colon Rectum       Date:  2019-02       Impact factor: 4.585

4.  Decreasing Utilization of Inferior Vena Cava Filters in Post-FDA Warning Era: Insights From 2005 to 2014 Nationwide Inpatient Sample.

Authors:  Vibhor Wadhwa; Premal S Trivedi; Kshitij Chatterjee; Anobel Tamrazi; Kelvin Hong; Mark L Lessne; Robert K Ryu
Journal:  J Am Coll Radiol       Date:  2017-06-15       Impact factor: 5.532

5.  Acute renal failure after coronary intervention: incidence, risk factors, and relationship to mortality.

Authors:  P A McCullough; R Wolyn; L L Rocher; R N Levin; W W O'Neill
Journal:  Am J Med       Date:  1997-11       Impact factor: 4.965

Review 6.  Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale.

Authors:  Golafsoun Ameri; John S H Baxter; Daniel Bainbridge; Terry M Peters; Elvis C S Chen
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-08-31       Impact factor: 2.924

7.  Mixed Reality in Visceral Surgery: Development of a Suitable Workflow and Evaluation of Intraoperative Use-cases.

Authors:  Igor M Sauer; Moritz Queisner; Peter Tang; Simon Moosburner; Ole Hoepfner; Rosa Horner; Rudiger Lohmann; Johann Pratschke
Journal:  Ann Surg       Date:  2017-11       Impact factor: 12.969

8.  Syncope as an emergency department presentation of pulmonary embolism.

Authors:  T R Wolfe; T L Allen
Journal:  J Emerg Med       Date:  1998 Jan-Feb       Impact factor: 1.484

9.  Incidence and prognostic importance of acute renal failure after percutaneous coronary intervention.

Authors:  Charanjit S Rihal; Stephen C Textor; Diane E Grill; Peter B Berger; Henry H Ting; Patricia J Best; Mandeep Singh; Malcolm R Bell; Gregory W Barsness; Verghese Mathew; Kirk N Garratt; David R Holmes
Journal:  Circulation       Date:  2002-05-14       Impact factor: 29.690

Review 10.  The clinical burden of contrast media-induced nephropathy.

Authors:  Francesco Liistro; Giovanni Falsini; Leonardo Bolognese
Journal:  Ital Heart J       Date:  2003-10
  10 in total
  3 in total

1.  [Application of mixed reality technique for the surgery of oral and maxillofacial tumors].

Authors:  Z N Tang; Y Hui; L H Hu; Y Yu; W B Zhang; X Peng
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-18

2.  A world's first attempt of mixed-reality system guided inferior vena cava filter implantation under remote guidance of 5G communication.

Authors:  Hang Zhu; Yao Li; Guang Gong; Mao-Xiang Zhao; Lin Liu; Si-Yu Yao; Chi Wang; Xin Li; Yun-Dai Chen
Journal:  J Geriatr Cardiol       Date:  2021-03-28       Impact factor: 3.327

3.  Accuracy of Mixed Reality Combined With Surgical Navigation Assisted Oral and Maxillofacial Tumor Resection.

Authors:  Zu-Nan Tang; Lei-Hao Hu; Hui Yuh Soh; Yao Yu; Wen-Bo Zhang; Xin Peng
Journal:  Front Oncol       Date:  2022-01-14       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.