Literature DB >> 28840168

Size-based quality-informed framework for quantitative optimization of pediatric CT.

Ehsan Samei1, Xiang Li2, Donald P Frush3.   

Abstract

The purpose of this study was to formulate a systematic, evidence-based method to relate quantitative diagnostic performance to radiation dose, enabling a multidimensional system to optimize computed tomography imaging across pediatric populations. Based on two prior foundational studies, radiation dose was assessed in terms of organ doses, effective dose ([Formula: see text]), and risk index for 30 patients within nine color-coded pediatric age-size groups as a function of imaging parameters. The cases, supplemented with added noise and simulated lesions, were assessed in terms of nodule detection accuracy in an observer receiving operating characteristic study. The resulting continuous accuracy-dose relationships were used to optimize individual scan parameters. Before optimization, the nine protocols had a similar [Formula: see text] of [Formula: see text] with accuracy decreasing from 0.89 for the youngest patients to 0.67 for the oldest. After optimization, a consistent target accuracy of 0.83 was established for all patient categories with [Formula: see text] ranging from 1 to 10 mSv. Alternatively, isogradient operating points targeted a consistent ratio of accuracy-per-unit-dose across the patient categories. The developed model can be used to optimize individual scan parameters and provide for consistent diagnostic performance across the broad range of body sizes in children.

Entities:  

Keywords:  children; computed tomography; diagnostic accuracy; image quality; lung nodule; pediatric; radiation dose; size-specific protocols

Year:  2017        PMID: 28840168      PMCID: PMC5565677          DOI: 10.1117/1.JMI.4.3.031209

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  45 in total

1.  Childhood cancer--mainly curable so where next?

Authors:  A W Craft
Journal:  Acta Paediatr       Date:  2000-04       Impact factor: 2.299

2.  Dose reduction in pediatric CT: a rational approach.

Authors:  John M Boone; Estella M Geraghty; J Anthony Seibert; Sandra L Wootton-Gorges
Journal:  Radiology       Date:  2003-08       Impact factor: 11.105

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  The application of effective dose to medical exposures.

Authors:  Colin J Martin
Journal:  Radiat Prot Dosimetry       Date:  2007-10-20       Impact factor: 0.972

5.  Helical CT of the body: are settings adjusted for pediatric patients?

Authors:  A Paterson; D P Frush; L F Donnelly
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

6.  Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large Children's Hospital.

Authors:  L F Donnelly; K H Emery; A S Brody; T Laor; V M Gylys-Morin; C G Anton; S R Thomas; D P Frush
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

7.  National survey of doses from CT in the UK: 2003.

Authors:  P C Shrimpton; M C Hillier; M A Lewis; M Dunn
Journal:  Br J Radiol       Date:  2006-12       Impact factor: 3.039

8.  Distinguishing benign from malignant pulmonary nodules with helical chest CT in children with malignant solid tumors.

Authors:  M Beth McCarville; Henrique M Lederman; Victor M Santana; Najat C Daw; Stephen J Shochat; Chin-Shang Li; Robert A Kaufman
Journal:  Radiology       Date:  2006-05       Impact factor: 11.105

9.  Improved pediatric multidetector body CT using a size-based color-coded format.

Authors:  Donald P Frush; Britt Soden; Karen S Frush; Carolyn Lowry
Journal:  AJR Am J Roentgenol       Date:  2002-03       Impact factor: 3.959

10.  Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients.

Authors:  Dianna D Cody; Donna M Moxley; Kerry T Krugh; Jennifer C O'Daniel; Louis K Wagner; Farzin Eftekhari
Journal:  AJR Am J Roentgenol       Date:  2004-04       Impact factor: 3.959

View more
  1 in total

1.  Detection of unwarranted CT radiation exposure from patient and imaging protocol meta-data using regularized regression.

Authors:  Ruidi Chen; Ioannis Ch Paschalidis; Hiroto Hatabu; Vladimir I Valtchinov; Jenifer Siegelman
Journal:  Eur J Radiol Open       Date:  2019-06-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.