Abstract

OBJECTIVE: CT technique should be adjusted while scanning infants and children. One format that has proven successful in simplifying pediatric care and reducing medical error is the size-based, color-coded Broselow-Luten pediatric system. This color-coded system can serve as a format for CT protocols. The purpose of this investigation was to compare variation (or error) occurrence and technologist preference for conventional and color-coded formats for pediatric multidetector body CT protocols.
MATERIALS AND METHODS: Multidetector CT examinations were set up using either a conventional or a color-coded format for a period of 6 weeks each. Variations (errors) from protocol parameters (including tube current, detector configuration, table speed, and IV contrast media dose) were tabulated. Qualitative assessment consisted of a survey of CT technologists (n = 20) for preference in six areas related to ease of use and clarity of the formats.
RESULTS: There were 44 CT examinations (n = 30 infants and children) in the conventional group and 55 CT examinations (n = 31 infants and children) in the color-coded protocol format group. Overall, the number of errors was significantly less in the color-coded group (p < 0.01), with a significantly lower error percentage in individual parameters affecting radiation dose, including tube current, detector configuration, and table speed (p < 0.05). In all areas, the color-coded format was preferred over the conventional format (p < 0.0003).
CONCLUSION: Color-coded CT formatting is an extension of a clinical color-coded system. This system provides an easy, expeditious, consistent, and preferable format for general pediatric body CT protocols. Most importantly, the color-coded system can reduce variations (errors) in the radiology department.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11856705     DOI: 10.2214/ajr.178.3.1780721

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  13 in total

1.  Management of patient dose and image noise in routine pediatric CT abdominal examinations.

Authors:  Francis R Verdun; D Lepori; Pascal Monnin; Jean-François Valley; Pierre Schnyder; F Gudinchet
Journal:  Eur Radiol       Date:  2004-01-13       Impact factor: 5.315

Review 2.  Multislice CT: update on radiation and screening.

Authors:  Mannudeep K Kalra; Michael M Maher; Sanjay Saini
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

3.  Image quality and dose optimisation for infant CT using a paediatric phantom.

Authors:  Jack W Lambert; Andrew S Phelps; Jesse L Courtier; Robert G Gould; John D MacKenzie
Journal:  Eur Radiol       Date:  2015-08-26       Impact factor: 5.315

4.  Paediatric CT reference doses based on weight and CT dosimetry phantom size: local experience using a 64-slice CT scanner.

Authors:  Debbie J Watson; Kerry S Coakley
Journal:  Pediatr Radiol       Date:  2010-01-13

5.  Size-based quality-informed framework for quantitative optimization of pediatric CT.

Authors:  Ehsan Samei; Xiang Li; Donald P Frush
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-21

Review 6.  CT dose reduction in children.

Authors:  Peter Vock
Journal:  Eur Radiol       Date:  2005-08-10       Impact factor: 5.315

7.  Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation.

Authors:  Hyun Woo Goo; Hyum Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-02-25

Review 8.  Chest computed tomography angiography in children on extracorporeal membrane oxygenation (ECMO).

Authors:  Nathan C Hull; Gary R Schooler; Larry A Binkovitz; Eric E Williamson; Phillip A Araoz; Lifeng Yu; Philip M Young
Journal:  Pediatr Radiol       Date:  2017-12-07

Review 9.  [Low dose multislice CT in the pediatric patient].

Authors:  A Hojreh; F Kainberger; S Puig
Journal:  Radiologe       Date:  2003-12       Impact factor: 0.635

Review 10.  Multidetector CT in children: current concepts and dose reduction strategies.

Authors:  Rutger A J Nievelstein; Ingrid M van Dam; Aart J van der Molen