Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients.

Dianna D Cody1, Donna M Moxley, Kerry T Krugh, Jennifer C O'Daniel, Louis K Wagner, Farzin Eftekhari.   

Abstract

OBJECTIVE: Our aim was to formulate appropriate MDCT chest and abdominopelvic CT scan protocols for pediatric patients.
MATERIALS AND METHODS: Surface radiation dose measurements from a set of anthropomorphic phantoms (nominal 1 year old, 5 year old, and 10 year old) and an adult phantom were compared with standard CT dose index measurements. Image-noise values on axial 5-mm-thick anthropomorphic phantom images were obtained as a measure of image quality.
RESULTS: Peripheral CT dose index values obtained with the standard 16-cm acrylic phantom were within approximately 10% of the CT surface dose measurements for the pediatric anthropomorphic phantoms for both chest and abdominopelvic scan protocols. The noise value for the adult phantom image acquired using a typical clinical CT technique was identified, and targeting this level of noise for pediatric CT examinations resulted in a decrease in dose of 60-90%. Initially, 80 kVp was selected for use with very small children; however, beam-hardening artifacts were severe enough to cause us to abandon this option. Current pediatric protocols at M. D. Anderson Cancer Center rely on 100- and 120-kVp settings. The display field-of-view parameter can be used as a surrogate for patient size to develop clinical pediatric CT protocol charts.
CONCLUSION: CT dose index measurements obtained using the 16-cm standard acrylic phantom are sufficiently accurate for estimating chest and abdominopelvic CT entrance exposures for pediatric patients of the same approximate size as the anthropomorphic phantoms used in this study. Image-noise measurements can be used to adjust chest and abdominopelvic CT techniques for pediatric populations, resulting in a decrease in measured entrance dose by 60-90%.

Entities:  

Mesh:

Year:  2004        PMID: 15039151     DOI: 10.2214/ajr.182.4.1820849

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  24 in total

Review 1.  Exposing the thyroid to radiation: a review of its current extent, risks, and implications.

Authors:  Bridget Sinnott; Elaine Ron; Arthur B Schneider
Journal:  Endocr Rev       Date:  2010-07-21       Impact factor: 19.871

2.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

Review 3.  Coronary CT angiography: Dose reduction strategies.

Authors:  Akmal Sabarudin; Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

4.  IAEA survey of paediatric computed tomography practice in 40 countries in Asia, Europe, Latin America and Africa: procedures and protocols.

Authors:  Jenia Vassileva; Madan M Rehani; Kimberly Applegate; Nada A Ahmed; Humoud Al-Dhuhli; Huda M Al-Naemi; Jamila Salem Al Suwaidi; Danijela Arandjic; Adnan Beganovic; Tony Benavente; Simone Dias; Leila El-Nachef; Dario Faj; Mirtha E Gamarra-Sánchez; Juan Garcia Aguilar; Vesna Gershan; Eduard Gershkevitsh; Edward Gruppetta; Alexandru Hustuc; Sonja Ivanovic; Arif Jauhari; Mohammad Hassan Kharita; Siarhei Kharuzhyk; Nadia Khelassi-Toutaoui; Hamid Reza Khosravi; Desislava Kostova-Lefterova; Ivana Kralik; Lantao Liu; Jolanta Mazuoliene; Patricia Mora; Wilbroad Muhogora; Pirunthavany Muthuvelu; Denisa Nikodemova; Leos Novak; Aruna S Pallewatte; Mohamed Shaaban; Esti Shelly; Karapet Stepanyan; Eu-Leong Harvey J Teo; Naw Thelsy; Pannee Visrutaratna; Areesha Zaman; Dejan Zontar
Journal:  Eur Radiol       Date:  2012-09-01       Impact factor: 5.315

5.  Development of pediatric CT protocols for specific scanners: why bother?

Authors:  Dianna D Cody
Journal:  Pediatr Radiol       Date:  2014-10-11

6.  Role of Computed Tomography in Pediatric Chest Conditions.

Authors:  Aparna Irodi; R V Leena; Shailesh M Prabhu; Sridhar Gibikote
Journal:  Indian J Pediatr       Date:  2016-02-26       Impact factor: 1.967

7.  The accuracy of focused abdominal CT in patients presenting to the emergency department.

Authors:  Ali Latifi; Omid Torkzad; Fausto Labruto; Ulla Ullberg; Michael R Torkzad
Journal:  Emerg Radiol       Date:  2008-11-08

8.  CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland.

Authors:  Francis R Verdun; Daniel Gutierrez; John Paul Vader; Abbas Aroua; Leonor Trinidad Alamo-Maestre; François Bochud; François Gudinchet
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

9.  Scan time and patient dose for thoracic imaging in neonates and small children using axial volumetric 320-detector row CT compared to helical 64-, 32-, and 16- detector row CT acquisitions.

Authors:  Lucia J M Kroft; Joost J H Roelofs; Jacob Geleijns
Journal:  Pediatr Radiol       Date:  2009-12-08

Review 10.  Computed tomography and cystic fibrosis: promises and problems.

Authors:  Z A Aziz; J C Davies; E W Alton; A U Wells; D M Geddes; D M Hansell
Journal:  Thorax       Date:  2007-02       Impact factor: 9.139

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.