Literature DB >> 28839652

Scope to improve: a multi-centre audit of 16 064 colonoscopies looking at caecal intubation rates, over a 2-year period.

Ajay Mark Verma1, Nadine McGrath1, Paula Bennett2, John de Caestecker3, Andrew Dixon1, Jayne Eaden2, Peter Wurm3, Andrew Chilton1.   

Abstract

OBJECTIVE: Colonoscopy is the 'gold standard' assessment for large bowel mucosal pathology, but a complete examination is essential. The first national colonoscopy audit carried out in 1999 demonstrated caecal intubation rates (CIRs) of 56.9%. As a result, the Joint Advisory Group (JAG) on gastrointestinal endoscopy launched a programme of continuous quality improvement. JAG recommends that practitioners undertake 100+ procedures per annum with a target CIR of 90%. This current audit provides an assessment of performance against this quality standard.
DESIGN: Data were collected from all procedures undertaken in 2008-2009 from six hospitals across three English regions.
RESULTS: 16064 colonoscopies performed: CIR = 90.57% (95% CI 90.11% to 91.01%). Operators doing 100+ procedures per annum, CIR=91.76% (91.24% to 92.25%). Operators doing <100 procedures per annum, CIR=87.77% (86.82% to 88.67%). Gastroenterologists, CIR=91.01% (90.32% to 91.70%). Surgeons, CIR=91.03% (90.27% to 91.79%). Other practitioners, CIR=81.51% (78.79% to 84.22%). Bowel cancer screening programme (BCSP) colonoscopies, CIR=97.71% (97.07% to 98.34%). Non-screening colonoscopies, CIR=88.31% (95% CI 87.68% to 88.94%).
CONCLUSION: This audit of 16064 colonoscopies across three regions demonstrates aggregated achievement of the CIR quality standard. However, there is a significant performance gap when comparing BCSP colonoscopists with non-screening colonoscopists and the overall CIR of >90% is supported by the volume of BCSP colonoscopy. Endoscopists performing low volume colonoscopy (<100 per annum), have CIR of <90%. Endoscopists with low volume practice who do not meet the quality standards should engage in skills augmentation plus further training and increase volume of colonoscopy with local mentorship, or stop performing colonoscopy.

Entities:  

Year:  2012        PMID: 28839652      PMCID: PMC5517280          DOI: 10.1136/flgastro-2012-100118

Source DB:  PubMed          Journal:  Frontline Gastroenterol        ISSN: 2041-4137


  8 in total

Review 1.  Circumstances in which colonoscopy misses cancer.

Authors:  Linda Rabeneck; Lawrence F Paszat
Journal:  Frontline Gastroenterol       Date:  2010-04-01

2.  Colorectal cancer detection: time to abandon barium enema?

Authors:  M K Shariff; K Sheikh; N R Carroll; S Whitley; D Greenberg; M Parkes; E A B Cameron
Journal:  Frontline Gastroenterol       Date:  2011-01-19

3.  Epidemiological study of the relationship between volume and outcome after abdominal aortic aneurysm surgery in the UK from 2000 to 2005.

Authors:  P J E Holt; J D Poloniecki; I M Loftus; J A Michaels; M M Thompson
Journal:  Br J Surg       Date:  2007-04       Impact factor: 6.939

4.  Analysis of administrative data finds endoscopist quality measures associated with postcolonoscopy colorectal cancer.

Authors:  Nancy N Baxter; Rinku Sutradhar; Shawn S Forbes; Lawrence F Paszat; Refik Saskin; Linda Rabeneck
Journal:  Gastroenterology       Date:  2010-09-18       Impact factor: 22.682

5.  Association between colonoscopy rates and colorectal cancer mortality.

Authors:  Linda Rabeneck; Lawrence F Paszat; Refik Saskin; Therese A Stukel
Journal:  Am J Gastroenterol       Date:  2010-03-02       Impact factor: 10.864

6.  A prospective study of colonoscopy practice in the UK today: are we adequately prepared for national colorectal cancer screening tomorrow?

Authors:  C J A Bowles; R Leicester; C Romaya; E Swarbrick; C B Williams; O Epstein
Journal:  Gut       Date:  2004-02       Impact factor: 23.059

7.  Colorectal cancer detection by colonoscopy in a Swedish county, 1979-95.

Authors:  G Dafnis; P Blomqvist; F Granath; L Påhlman; A Ekbom
Journal:  Scand J Gastroenterol       Date:  2003-10       Impact factor: 2.423

8.  The Hawthorne Effect: a randomised, controlled trial.

Authors:  Rob McCarney; James Warner; Steve Iliffe; Robbert van Haselen; Mark Griffin; Peter Fisher
Journal:  BMC Med Res Methodol       Date:  2007-07-03       Impact factor: 4.615

  8 in total
  2 in total

1.  Should patients expect their colonoscopy to reach the standards experienced by bowel cancer screening patients?

Authors:  Matthew R Banks
Journal:  Frontline Gastroenterol       Date:  2012-04-24

2.  Correlation of caecal intubation rate to volume: colonoscopists should undertake at least 120 procedures per year.

Authors:  Ajay M Verma; Andrew D Dixon; Andrew P Chilton
Journal:  Frontline Gastroenterol       Date:  2013-12-17
  2 in total