| Literature DB >> 28831312 |
Juan M Giugale1, Mitchell S Fourman1, Deidre L Bielicka2, John R Fowler1.
Abstract
BACKGROUND: The dorsal tangential (DT) view has been shown to improve the detection of dorsal screw perforation during volar distal radius fracture fixation. Here we performed a cadaveric imaging survey study to evaluate if the DT view was uniformly beneficial for all screws.Entities:
Year: 2017 PMID: 28831312 PMCID: PMC5555008 DOI: 10.1155/2017/1402517
Source DB: PubMed Journal: Adv Orthop ISSN: 2090-3464
Figure 1Fluoroscopic (a) dorsal tangential and (b) traditional lateral views of third screw from the radial aspect of the plate with a 4 mm dorsal cortex protrusion, as presented during survey analysis. Yellow arrows denote the protruding screw.
Cohort and subgroup accuracy in the identification of screw prominence using either the DT or lateral views.
| Accuracy DT view | Accuracy lateral view |
| |
|---|---|---|---|
| Cohort ( | 78.6% | 62.4% | <.0001 |
| Attending ( | 80.3% | 65.6% | <.05 |
| Fellow ( | 73.2% | 65.8% | .39 |
| Resident ( | 80.2% | 57.6% | <.0001 |
Statistical significance (p < .05).
Overall accuracy based on imaging technique and screw position and degree of prominence.
| 1 (radial styloid) | 2 | 3 | 4 (ulnar corner) | |
|---|---|---|---|---|
| DT 0 mm | 84.6% (1 image) | |||
| Lat 0 mm | 85.7% (1 image) | |||
| DT 2 mm | 78.1 ± 4.4% | 100% (1 image) | 79.5 ± 11.4% | 50 ± 44.2% |
| Lat 2 mm | 5.9 ± 8.3% | 35.6 ± 49.01% | 18.9% (1 image) | 61.1% (1 image) |
| DT 4 mm | 93.45 ± 6.3% | 100% (1 image) | 60 ± 56.6% | 65.8 ± 40.0% |
| Lat 4 mm | 13.0 ± 1.8% | 75 ± 35.4% | 100% (1 image) | 83.3% (1 image) |
| DT 6 mm | 96.9 ± 4.4% | 100% (1 image) | 75.2 ± 26.8% | 78.9 ± 3.4% |
| Lat 6 mm | 49.4 ± 61.5% | 97.6 ± 4.1% | 100% (1 image) | 50.8 ± 61.7% |
(a) Lateral view
| Actual screw prominence | |||
| Prominent | Not prominent | ||
|
| |||
| Survey response | Prominent | 212 | 128 |
| Not prominent | 8 | 22 | |
| Sensitivity | 96.4% | ||
| Specificity | 14.7% | ||
| PPV | 62.4% | ||
| NPV | 73.3% | ||
(b) DT view
| Actual screw prominence | |||
| Prominent | Not prominent | ||
|
| |||
| Survey response | Prominent | 274 | 71 |
| Not prominent | 8 | 21 | |
| Sensitivity | 97.2% | ||
| Specificity | 22.8% | ||
| PPV | 79.4% | ||
| NPV | 72.4% | ||