Literature DB >> 25457447

The dorsal tangential X-ray view to determine dorsal screw penetration during volar plating of distal radius fractures.

Alexander Brunner1, Christin Siebert2, Claudia Stieger1, Alexander Kastius1, Björn-Christian Link1, Reto Babst1.   

Abstract

PURPOSE: To evaluate whether the dorsal tangential view (DTV) allows for reliable and valid in vivo measurement of the distance between screw tips and the dorsal radial cortex (STCD) during volar plating of distal radius fractures.
METHODS: Subjects included 22 patients with displaced distal radius fractures who had volar plate osteosynthesis. We performed standardized DTV images intraoperatively. After surgery, we performed computed tomography (CT) scans with reconstructions parallel to the distal screws. Three independent observers blinded to the study protocol measured the STCD on the basis of the DTV images and CT reconstructions. We calculated inter- and intraobserver reliability and the correlation between STCD values measured with DTV images and CT scans.
RESULTS: Eleven screws were changed intraoperatively. We observed no cases of postoperative screw perforations. Inter- and intraobserver reliability of STCD measurement was good when measured with DTV images and excellent when measured on the basis of CT reconstructions. Statistical analysis showed a good correlation between mean STCD values measured with DTV and CT.
CONCLUSIONS: The DTV allowed in vivo evaluation of the dorsal radial cortex and enabled reliable assessment of the distance between the screw tip and the dorsal cortex. It may allow detection of dorsal screw perforation during volar plating of distal radial fractures.
Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  DTV; distal radius; extensor tendon injury; screw perforation; volar plating

Mesh:

Year:  2014        PMID: 25457447     DOI: 10.1016/j.jhsa.2014.10.021

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  7 in total

1.  Detections of Screw Penetration during Volar Plating for Distal Radius Fractures.

Authors:  Soo Min Cha; Hyun Dae Shin
Journal:  J Wrist Surg       Date:  2017-06-02

2.  Carpal Translocation Following Dorsal Bridge Plate Fixation of Distal Radius Fractures: A Cadaveric Study.

Authors:  Ali Azad; Jessica M Intravia; J Ryan Hill; Hyuma Leland; Venus Vakhshori; Milan Stevanovic; Alidad Ghiassi
Journal:  J Wrist Surg       Date:  2019-03-18

3.  Immobilization following Distal Radius Fractures: A Randomized Clinical Trial.

Authors:  J Ryan Hill; Paul D Navo; Gabriel Bouz; Ali Azad; William Pannell; R Kiran Alluri; Alidad Ghiassi
Journal:  J Wrist Surg       Date:  2018-08-07

4.  Distal radius fluoroscopic skyline view: extension-supination versus flexion-supination.

Authors:  Laëla El Amiri; Yuka Igeta; Chiara Pizza; Sybille Facca; Juan José Hidalgo Diaz; Liverneaux Philippe
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-10-29

5.  Are Routine Radiographs Needed the Day After Open Reduction and Internal Fixation Surgery for Distal Radius and Ankle Fractures: Study Protocol for a Prospective, Open Label, Randomized Controlled Trial.

Authors:  Florian Oehme; Annika Rühle; Julia Mühlhäusser; Lana Fourie; Björn-Christian Link; Reto Babst; Frank Jp Beeres
Journal:  JMIR Res Protoc       Date:  2017-08-16

6.  Comparing Dorsal Tangential and Lateral Views of the Wrist for Detecting Dorsal Screw Penetration after Volar Plating of Distal Radius Fractures.

Authors:  Juan M Giugale; Mitchell S Fourman; Deidre L Bielicka; John R Fowler
Journal:  Adv Orthop       Date:  2017-07-31

7.  Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration.

Authors:  Yusuf Gurbuz; Levent Kucuk; Huseyin Gunay; Kemal Ozaksar; Tahir Sadik Sugun; Okan Bilge
Journal:  Acta Orthop Traumatol Turc       Date:  2017-11-01       Impact factor: 1.511

  7 in total