Two potential causes of EPL rupture after distal radius volar plate fixation.

Eric C Benson1, Alex DeCarvalho, Elizabeth A Mikola, John M Veitch, Moheb S Moneim.   

Abstract

Rupture of the extensor pollicis longus tendon can occur after volar plate fixation of dorsally comminuted distal radius fractures. We attempted to identify the etiology of extensor pollicis longus tendon injury after volar plate fixation of the distal radius and potential solutions to this problem. After describing two case reports, we examine six cadaveric specimens and retrospectively review 10 selected patients to evaluate possible technique refinements to minimize damage to the extensor pollicis longus tendon during volar plating of the distal radius. We identify specific screw holes in three commercially available volar distal radius plates that direct the drill bit or prominent screw tips into the third extensor compartment. In addition, after reduction and plate fixation, bone fragments or dorsal gapping may predispose the extensor pollicis longus tendon to injury. We recommend either using shorter screw lengths or leaving the implicated plate holes unfilled. In addition, we suggest consideration of an open assessment of the third extensor compartment, if indicated, as performed through a small dorsal incision ulnar to Lister's tubercle.

Entities:  

Mesh:

Year:  2006        PMID: 16770281     DOI: 10.1097/01.blo.0000223998.02765.0d

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  31 in total

1.  The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures.

Authors:  Lucile Vaiss; Satoshi Ichihara; Sarah Hendriks; Chihab Taleb; Philippe Liverneaux; Sybille Facca
Journal:  J Wrist Surg       Date:  2014-11

2.  Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating.

Authors:  Kagan Ozer; Serdar Toker
Journal:  Hand (N Y)       Date:  2011-01-07

3.  Anatomical and radiological study applied to distal radius surgery.

Authors:  N Gasse; D Lepage; R Pem; C Bernard; J M Lerais; P Garbuio; L Obert
Journal:  Surg Radiol Anat       Date:  2010-12-07       Impact factor: 1.246

4.  The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates.

Authors:  Lindley B Wall; Michael D Brodt; Matthew J Silva; Martin I Boyer; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2012-02-02       Impact factor: 2.230

5.  Detections of Screw Penetration during Volar Plating for Distal Radius Fractures.

Authors:  Soo Min Cha; Hyun Dae Shin
Journal:  J Wrist Surg       Date:  2017-06-02

6.  Volar locking plate fixation of distal radius fractures: use of an intra-operative 'carpal shoot through' view to identify dorsal compartment and distal radioulnar joint screw penetration.

Authors:  Daniel Marsland; Chris M Hobbs; Philip S Sauvé
Journal:  Hand (N Y)       Date:  2014-12

7.  Cadaver study of the topography of the musculotendinous junction of the finger extensor muscles: applicability to tendon rupture following closed wrist trauma.

Authors:  D Lepage; L Tatu; F Loisel; F Vuillier; B Parratte
Journal:  Surg Radiol Anat       Date:  2015-01-11       Impact factor: 1.246

8.  Sonographic assessment of orthopedic hardware impingement on soft tissues of the limbs.

Authors:  R Guillin; S Bianchi
Journal:  J Ultrasound       Date:  2012-01-23

9.  A Prospective Observational Assessment of Unicortical Distal Screw Placement During Volar Plate Fixation of Distal Radius Fractures.

Authors:  Agnes Z Dardas; Charles A Goldfarb; Martin I Boyer; Daniel A Osei; Christopher J Dy; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2018-02-01       Impact factor: 2.230

10.  Volar plate fixation of intra-articular distal radius fractures: a retrospective study.

Authors:  Margaret W M Fok; Melissa A Klausmeyer; Diego L Fernandez; Jorge L Orbay; Alex Lluch Bergada
Journal:  J Wrist Surg       Date:  2013-08