Literature DB >> 27769074

The Detection of Prominent Hardware in Volar Locked Plating of Distal Radius Fractures: Intraoperative Fluoroscopy Versus Computed Tomography.

Devin Ganesh1, Ben Service, Brian Zirgibel, Kenneth Koval.   

Abstract

OBJECTIVES: To assess the utility of the dorsal tangential view (DTV) in detecting intraoperative dorsal screw penetration in distal radius fractures treated with volar locked plating.
DESIGN: Retrospective cohort study.
SETTING: Academic level 1 trauma center. PATIENTS/PARTICIPANTS: Skeletally mature patients where open reduction internal fixation with volar locked plating was the definitive treatment. A total of twenty-six patients were evaluated. INTERVENTION: Intraoperative anteroposterior, lateral, 20 degree tilted lateral, and DTVs were obtained through fluoroscopy in all wrists. Screw exchange and position by fluoroscopic view was recorded. A computed tomography (CT) was taken postoperatively to identify residual prominent screws. MAIN OUTCOME MEASURES: Data points included frequency of screw exchange by standard fluoroscopic views, the DTV, and residual prominent screws detected by CT.
RESULTS: Eight constructs of thirty (27%) had prominent screws evident on the DTV but not seen on standard fluoroscopic analysis. CT identified 5 additional screws with ≥1 mm dorsal penetration not identified by the DTV. All except 1 screw was in the second dorsal wrist compartment. The DTV was 67% sensitive with a negative predictive value of 97%.
CONCLUSION: It is risky and unnecessary to place bicortical screws in the distal part of a volar plate. Given that the DTV view was not sufficient to avoid dorsal screw prominence, distal screws should be intentionally 2-4 mm shorter than measured. Recent studies propose bicortical distal locking screws are not needed for sufficient construct stiffness in volar locked plating. We suggest caution when using this view to verify acceptable placement of screws in proximity to the second dorsal compartment. LEVEL OF EVIDENCE: Diagnostic level III. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2016        PMID: 27769074     DOI: 10.1097/BOT.0000000000000661

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  2 in total

1.  A Prospective Observational Assessment of Unicortical Distal Screw Placement During Volar Plate Fixation of Distal Radius Fractures.

Authors:  Agnes Z Dardas; Charles A Goldfarb; Martin I Boyer; Daniel A Osei; Christopher J Dy; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2018-02-01       Impact factor: 2.230

2.  Comparing Dorsal Tangential and Lateral Views of the Wrist for Detecting Dorsal Screw Penetration after Volar Plating of Distal Radius Fractures.

Authors:  Juan M Giugale; Mitchell S Fourman; Deidre L Bielicka; John R Fowler
Journal:  Adv Orthop       Date:  2017-07-31