Literature DB >> 28829307

Robust Self-Calibrating nCPMG Acquisition: Application to Body Diffusion-Weighted Imaging.

Eric K Gibbons, Patrick Le Roux, Shreyas S Vasanawala, John M Pauly, Adam B Kerr.   

Abstract

This paper demonstrates a robust diffusion-weighted single-shot fast spin echo (SS-FSE) sequence in the presence of significant off-resonance, which includes a variable-density acquisition and a self-calibrated reconstruction as improvements. A non-Carr-Purcell-Meiboom-Gill (nCPMG) SS-FSE acquisition stabilizes both the main and parasitic echo families for each echo. This preserves both the in-phase and quadrature components of the magnetization throughout the echo train. However, nCPMG SS-FSE also promotes aliasing of the quadrature component, which complicates reconstruction. A new acquisition and reconstruction approach is presented here, where the field-of-view is effectively doubled, but a partial k-space and variable density sampling is used to improve scan efficiency. The technique is presented in phantom scans to validate SNR and robustness against rapidly varying object phase. In vivo healthy volunteer examples and the clinical cases are demonstrated in abdominal imaging. This new approach provides comparable SNR to previous nCPMG acquisition techniques as well as providing more uniform apparent diffusion coefficient maps in phantom scans. In vivo scans suggest that this method is more robust against motion than previous approaches. The proposed reconstruction is an improvement to the nCPMG sequence as it is auto-calibrating and is justified to accurately treat the signal model for the nCPMG SS-FSE sequence.

Entities:  

Mesh:

Year:  2017        PMID: 28829307      PMCID: PMC5784776          DOI: 10.1109/TMI.2017.2741421

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  23 in total

1.  Multishot diffusion-weighted FSE using PROPELLER MRI.

Authors:  James G Pipe; Victoria G Farthing; Kirsten P Forbes
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

2.  On the application of a non-CPMG single-shot fast spin-echo sequence to diffusion tensor MRI of the human brain.

Authors:  Mark E Bastin; Patrick Le Roux
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

3.  On the application of ultra-fast RARE experiments.

Authors:  D G Norris; P Börnert; T Reese; D Leibfritz
Journal:  Magn Reson Med       Date:  1992-09       Impact factor: 4.668

4.  Phase insensitive preparation of single-shot RARE: application to diffusion imaging in humans.

Authors:  D C Alsop
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

5.  Diffusion tensor imaging of the human optic nerve using a non-CPMG fast spin echo sequence.

Authors:  Steren Chabert; Nicolas Molko; Yann Cointepas; Patrick Le Roux; Denis Le Bihan
Journal:  J Magn Reson Imaging       Date:  2005-08       Impact factor: 4.813

6.  Partial k-space reconstruction in single-shot diffusion-weighted echo-planar imaging.

Authors:  Pippa Storey; Fred J Frigo; R Scott Hinks; Bryan J Mock; Bruce D Collick; Nicole Baker; Jonathan Marmurek; Simon J Graham
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

7.  Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Authors:  Olaf Dietrich; José G Raya; Scott B Reeder; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

8.  Diffusion-weighted imaging with dual-echo echo-planar imaging for better sensitivity to acute stroke.

Authors:  S J Holdsworth; K W Yeom; M U Antonucci; J B Andre; J Rosenberg; M Aksoy; M Straka; N J Fischbein; R Bammer; M E Moseley; G Zaharchuk; S Skare
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-24       Impact factor: 3.825

9.  Slice profile effects on nCPMG SS-FSE.

Authors:  Eric K Gibbons; Patrick Le Roux; John M Pauly; Adam B Kerr
Journal:  Magn Reson Med       Date:  2017-03-31       Impact factor: 4.668

10.  ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.

Authors:  Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more
  1 in total

1.  Body diffusion-weighted imaging using magnetization prepared single-shot fast spin echo and extended parallel imaging signal averaging.

Authors:  Eric K Gibbons; Shreyas S Vasanawala; John M Pauly; Adam B Kerr
Journal:  Magn Reson Med       Date:  2017-10-17       Impact factor: 4.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.