Literature DB >> 28798205

Cardiac output by pulse contour analysis does not match the increase measured by rebreathing during human spaceflight.

Richard L Hughson1, Sean D Peterson2, Nicholas J Yee3, Danielle K Greaves3.   

Abstract

Pulse contour analysis of the noninvasive finger arterial pressure waveform provides a convenient means to estimate cardiac output (Q̇). The method has been compared with standard methods under a range of conditions but never before during spaceflight. We compared pulse contour analysis with the Modelflow algorithm to estimates of Q̇ obtained by rebreathing during preflight baseline testing and during the final month of long-duration spaceflight in nine healthy male astronauts. By Modelflow analysis, stroke volume was greater in supine baseline than seated baseline or inflight. Heart rate was reduced in supine baseline so that there were no differences in Q̇ by Modelflow estimate between the supine (7.02 ± 1.31 l/min, means ± SD), seated (6.60 ± 1.95 l/min), or inflight (5.91 ± 1.15 l/min) conditions. In contrast, rebreathing estimates of Q̇ increased from seated baseline (4.76 ± 0.67 l/min) to inflight (7.00 ± 1.39 l/min, significant interaction effect of method and spaceflight, P < 0.001). Pulse contour analysis utilizes a three-element Windkessel model that incorporates parameters dependent on aortic pressure-area relationships that are assumed to represent the entire circulation. We propose that a large increase in vascular compliance in the splanchnic circulation invalidates the model under conditions of spaceflight. Future spaceflight research measuring cardiac function needs to consider this important limitation for assessing absolute values of Q̇ and stroke volume.NEW &amp; NOTEWORTHY Noninvasive assessment of cardiac function during human spaceflight is an important tool to monitor astronaut health. This study demonstrated that pulse contour analysis of finger arterial blood pressure to estimate cardiac output failed to track the 46% increase measured by a rebreathing method. These results strongly suggest that alternative methods not dependent on pulse contour analysis are required to track cardiac function in spaceflight.
Copyright © 2017 the American Physiological Society.

Entities:  

Keywords:  Modelflow; aortic compliance; arterial blood pressure; astronaut; stroke volume

Mesh:

Year:  2017        PMID: 28798205      PMCID: PMC5792103          DOI: 10.1152/japplphysiol.00651.2017

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  33 in total

1.  Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique.

Authors:  Anders Gabrielsen; Regitze Videbaek; Morten Schou; Morten Damgaard; Jens Kastrup; Peter Norsk
Journal:  Clin Sci (Lond)       Date:  2002-02       Impact factor: 6.124

Review 2.  Syncope, cerebral perfusion, and oxygenation.

Authors:  Johannes J Van Lieshout; Wouter Wieling; John M Karemaker; Niels H Secher
Journal:  J Appl Physiol (1985)       Date:  2003-03

3.  The nutritional status of astronauts is altered after long-term space flight aboard the International Space Station.

Authors:  Scott M Smith; Sara R Zwart; Gladys Block; Barbara L Rice; Janis E Davis-Street
Journal:  J Nutr       Date:  2005-03       Impact factor: 4.798

4.  Control of red blood cell mass in spaceflight.

Authors:  C P Alfrey; M M Udden; C Leach-Huntoon; T Driscoll; M H Pickett
Journal:  J Appl Physiol (1985)       Date:  1996-07

5.  Central venous pressure in space.

Authors:  J C Buckey; F A Gaffney; L D Lane; B D Levine; D E Watenpaugh; S J Wright; C W Yancy; D M Meyer; C G Blomqvist
Journal:  J Appl Physiol (1985)       Date:  1996-07

6.  Cardiovascular response to submaximal exercise in sustained microgravity.

Authors:  B E Shykoff; L E Farhi; A J Olszowka; D R Pendergast; M A Rokitka; C G Eisenhardt; R A Morin
Journal:  J Appl Physiol (1985)       Date:  1996-07

7.  Upright cardiac output measurements in the transition to weightlessness during parabolic flights.

Authors:  Ulrich Limper; Peter Gauger; Luis E J Beck
Journal:  Aviat Space Environ Med       Date:  2011-04

8.  Effect of gravity and microgravity on intracranial pressure.

Authors:  Justin S Lawley; Lonnie G Petersen; Erin J Howden; Satyam Sarma; William K Cornwell; Rong Zhang; Louis A Whitworth; Michael A Williams; Benjamin D Levine
Journal:  J Physiol       Date:  2017-02-14       Impact factor: 5.182

9.  The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model.

Authors:  G J Langewouters; K H Wesseling; W J Goedhard
Journal:  J Biomech       Date:  1984       Impact factor: 2.712

10.  Lumbar Spine Paraspinal Muscle and Intervertebral Disc Height Changes in Astronauts After Long-Duration Spaceflight on the International Space Station.

Authors:  Douglas G Chang; Robert M Healey; Alexander J Snyder; Jojo V Sayson; Brandon R Macias; Dezba G Coughlin; Jeannie F Bailey; Scott E Parazynski; Jeffrey C Lotz; Alan R Hargens
Journal:  Spine (Phila Pa 1976)       Date:  2016-12-15       Impact factor: 3.241

View more
  5 in total

1.  Indirect measurement of absolute cardiac output during exercise in simulated altered gravity is highly dependent on the method.

Authors:  Richard S Whittle; Lindsay M Stapleton; Lonnie G Petersen; Ana Diaz-Artiles
Journal:  J Clin Monit Comput       Date:  2021-10-22       Impact factor: 1.977

2.  Inflight leg cuff test does not identify the risk for orthostatic hypotension after long-duration spaceflight.

Authors:  Katelyn N Wood; Kevin R Murray; Danielle K Greaves; Richard L Hughson
Journal:  NPJ Microgravity       Date:  2019-10-11       Impact factor: 4.415

Review 3.  A perspective on spaceflight associated neuro-ocular syndrome causation secondary to elevated venous sinus pressure.

Authors:  Grant Alexander Bateman; Alexander Robert Bateman
Journal:  NPJ Microgravity       Date:  2022-02-15       Impact factor: 4.970

Review 4.  Implementation of exercise countermeasures during spaceflight and microgravity analogue studies: Developing countermeasure protocols for bedrest in older adults (BROA).

Authors:  Eric T Hedge; Courtney A Patterson; Carmelo J Mastrandrea; Vita Sonjak; Guy Hajj-Boutros; Andréa Faust; José A Morais; Richard L Hughson
Journal:  Front Physiol       Date:  2022-08-09       Impact factor: 4.755

5.  Efficacy of fluid loading as a countermeasure to the hemodynamic and hormonal changes of 28-h head-down bed rest.

Authors:  Heather Edgell; Anna Grinberg; Keith R Beavers; Nathalie Gagné; Richard L Hughson
Journal:  Physiol Rep       Date:  2018-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.