Literature DB >> 34677821

Indirect measurement of absolute cardiac output during exercise in simulated altered gravity is highly dependent on the method.

Richard S Whittle1, Lindsay M Stapleton1, Lonnie G Petersen2, Ana Diaz-Artiles3,4.   

Abstract

PURPOSE: Altered gravity environments introduce cardiovascular changes that may require continuous hemodynamic monitoring in both spaceflight and terrestrial analogs. Conditions in such environments are often prohibitive to direct/invasive methods and therefore, indirect measurement techniques must be used. This study compares two common cardiac measurement techniques used in the human spaceflight domain, pulse contour analysis (PCA-Nexfin) and inert gas rebreathing (IGR-Innocor), in subjects completing ergometer exercise under altered gravity conditions simulated using a tilt paradigm.
METHODS: Seven subjects were tilted to three different angles representing Martian, Lunar, and microgravity conditions in the rostrocaudal direction. They completed a 36-min submaximal cardiovascular exercise protocol in each condition. Hemodynamics were continuously monitored using Nexfin and Innocor.
RESULTS: Linear mixed-effects models revealed a significant bias of [Formula: see text] ml ([Formula: see text]) in stroke volume and [Formula: see text] l/min ([Formula: see text]) in cardiac output, with Nexfin measuring greater than Innocor in both variables. These values are in agreement with a Bland-Altman analysis. The correlation of stroke volume and cardiac output measurements between Nexfin and Innocor were [Formula: see text] ([Formula: see text]) and [Formula: see text] ([Formula: see text]) respectively.
CONCLUSION: There is a poor agreement in absolute stroke volume and cardiac output values between measurement via PCA (Nexfin) and IGR (Innocor) in subjects who are exercising in simulated altered gravity environments. These results suggest that the chosen measurement method and device greatly impacts absolute measurements of cardiac output. However, there is a good level of agreement between the two devices when measuring relative changes. Either of these devices seem adequate to capture cardiac changes, but should not be solely relied upon for accurate measurement of absolute cardiac output.
© 2021. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Altered gravity; Cardiac output; Inert gas rebreathing; Innocor; Nexfin; Pulse contour analysis

Mesh:

Year:  2021        PMID: 34677821     DOI: 10.1007/s10877-021-00769-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   1.977


  50 in total

Review 1.  Plasma and blood volume in space.

Authors:  André Diedrich; Sachin Y Paranjape; David Robertson
Journal:  Am J Med Sci       Date:  2007-07       Impact factor: 2.378

2.  Dynamic adaptation of cardiac baroreflex sensitivity to prolonged exposure to microgravity: data from a 16-day spaceflight.

Authors:  M Di Rienzo; P Castiglioni; F Iellamo; M Volterrani; M Pagani; G Mancia; J M Karemaker; G Parati
Journal:  J Appl Physiol (1985)       Date:  2008-08-28

3.  Adaptation of heart rate and blood pressure to short and long duration space missions.

Authors:  Bart Verheyden; Jiexin Liu; Frank Beckers; André E Aubert
Journal:  Respir Physiol Neurobiol       Date:  2009-03-28       Impact factor: 1.931

4.  Central venous pressure in humans during microgravity.

Authors:  N Foldager; T A Andersen; F B Jessen; P Ellegaard; C Stadeager; R Videbaek; P Norsk
Journal:  J Appl Physiol (1985)       Date:  1996-07

5.  Central venous pressure in space.

Authors:  J C Buckey; F A Gaffney; L D Lane; B D Levine; D E Watenpaugh; S J Wright; C W Yancy; D M Meyer; C G Blomqvist
Journal:  J Appl Physiol (1985)       Date:  1996-07

6.  Mechanisms of increase in cardiac output during acute weightlessness in humans.

Authors:  Lonnie G Petersen; Morten Damgaard; Johan C G Petersen; Peter Norsk
Journal:  J Appl Physiol (1985)       Date:  2011-06-02

7.  Microgravity decreases heart rate and arterial pressure in humans.

Authors:  J M Fritsch-Yelle; J B Charles; M M Jones; M L Wood
Journal:  J Appl Physiol (1985)       Date:  1996-03

8.  Human vagal baroreflex mechanisms in space.

Authors:  Dwain L Eckberg; John R Halliwill; Larry A Beightol; Troy E Brown; J Andrew Taylor; Ross Goble
Journal:  J Physiol       Date:  2010-02-15       Impact factor: 5.182

9.  Fluid shifts, vasodilatation and ambulatory blood pressure reduction during long duration spaceflight.

Authors:  Peter Norsk; Ali Asmar; Morten Damgaard; Niels Juel Christensen
Journal:  J Physiol       Date:  2015-02-01       Impact factor: 5.182

10.  Cardiac Effects of Repeated Weightlessness During Extreme Duration Swimming Compared With Spaceflight.

Authors:  James P MacNamara; Katrin A Dias; Satyam Sarma; Stuart M C Lee; David Martin; Maks Romeijn; Vlad G Zaha; Benjamin D Levine
Journal:  Circulation       Date:  2021-03-29       Impact factor: 29.690

View more
  1 in total

1.  The Influence of Altered-Gravity on Bimanual Coordination: Retention and Transfer.

Authors:  Ana Diaz-Artiles; Yiyu Wang; Madison M Davis; Renee Abbott; Nathan Keller; Deanna M Kennedy
Journal:  Front Physiol       Date:  2022-01-07       Impact factor: 4.566

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.