Literature DB >> 6480618

The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model.

G J Langewouters, K H Wesseling, W J Goedhard.   

Abstract

Segments of 45 human thoracic and 20 abdominal aortas, including 13 pairs, aged 30-88 yr at autopsy, were perfused with 37 degrees C Tyrode's solution at in-situ length. Diameter changes due to 20 mmHg pressure steps, between 20 and 180 mmHg, were measured to 1 micron accuracy with balanced transducers. Absolute diameter at 100 mmHg was measured to 50 micron accuracy. At 100 mmHg, cross-sectional area ranged from 2.6 to 7.6 for thoracic and from 1.0 to 3.2 cm2 for abdominal segments. Compliances ranged from 1.9 to 17 for thoracic and from 0.6 to 4.4 mm3/mmHg.cm for abdominal segments. An arctangent model with three free parameters A(p) = Am(1/2 + tan-1 [p-p0)/p1)/pi) explained over 99% of the variance in area with pressure for each aorta. Changes in compliance, characteristic impedance and propagation velocity are equally well described. Abdominal fits on the average appeared down scaled by a factor of 2 and shifted 20 mmHg towards lower pressures from paired thoracic (significant at p = 0.001).

Entities:  

Mesh:

Year:  1984        PMID: 6480618     DOI: 10.1016/0021-9290(84)90034-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  79 in total

1.  Mechanical properties of the fetal ductus venosus and umbilical vein.

Authors:  L R Hellevik; T Kiserud; F Irgens; N Stergiopulos; M Hanson
Journal:  Heart Vessels       Date:  1998       Impact factor: 2.037

2.  Assessment of the mechanical properties of coronary arteries using intravascular ultrasound: an in vivo study.

Authors:  M J Williams; R A Stewart; C J Low; G T Wilkins
Journal:  Int J Card Imaging       Date:  1999-08

3.  Effect of exercise training on biologic vascular age in healthy seniors.

Authors:  Shigeki Shibata; Benjamin D Levine
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-01-20       Impact factor: 4.733

4.  A passive strain-energy function for elastic and muscular arteries: correlation of material parameters with histological data.

Authors:  Dimitrios P Sokolis
Journal:  Med Biol Eng Comput       Date:  2010-06       Impact factor: 2.602

Review 5.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis.

Authors:  Ramakrishna Mukkamala; Da Xu
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-09       Impact factor: 4.733

6.  Modelflow underestimates cardiac output in heat-stressed individuals.

Authors:  Manabu Shibasaki; Thad E Wilson; Morten Bundgaard-Nielsen; Thomas Seifert; Niels H Secher; Craig G Crandall
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2010-11-17       Impact factor: 3.619

Review 7.  Is there a role for invasive hemodynamic monitoring in acute heart failure management?

Authors:  Daniel De Backer
Journal:  Curr Heart Fail Rep       Date:  2015-06

8.  Asymmetric time-dependent model for the dynamic finger arterial pressure-volume relationship.

Authors:  Jaak Talts; Rein Raamat; Kersti Jagomägi
Journal:  Med Biol Eng Comput       Date:  2006-08-03       Impact factor: 2.602

9.  Standard pulse contour methods are not applicable in animals.

Authors:  Jos R Jansen
Journal:  Intensive Care Med       Date:  2006-10-20       Impact factor: 17.440

Review 10.  Elastin and collagen fibre microstructure of the human aorta in ageing and disease: a review.

Authors:  Alkiviadis Tsamis; Jeffrey T Krawiec; David A Vorp
Journal:  J R Soc Interface       Date:  2013-03-27       Impact factor: 4.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.