Literature DB >> 11834145

Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique.

Anders Gabrielsen1, Regitze Videbaek, Morten Schou, Morten Damgaard, Jens Kastrup, Peter Norsk.   

Abstract

Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodilution (CO(TD)) methods in patients with heart failure or pulmonary hypertension. In 11 patients, of which three had shunt flow through areas without significant gas exchange, the mean difference (bias) and limits of agreement (+/- 2 S.D.) were 0.6 +/- 1.2 litre x min(-1) when comparing CO(FICK) and Q(EP), and -0.8 +/- 1.3 litre x min(-1) when comparing CO(FICK) and CO(TD). When correction for intrapulmonary shunt flow was applied (i.e. calculation of CO(RB)) in all 11 patients, the bias between CO(FICK) and CO(RB) was 0.1 +/- 0.9 litre x min(-1), primarily because agreement improved in the three patients with significant shunt flow. In the eight patients without significant shunt flow, the agreement between Q(EP) and CO(FICK) was 0.3 +/- 0.9 litre x min(-1). In conclusion, a foreign gas rebreathing method with a new infrared photoacoustic gas analyser provided at least as reliable a measure of cardiac output as did thermodilution. In the absence of significant shunt flow, measurement of Q(EP) itself provides a reliable estimate of cardiac output in heart failure patients. The infrared photoacoustic gas analyser markedly facilitates clinical use of the rebreathing method in general, which makes the method available to a larger group of clinicians working with patients with cardiovascular diseases.

Entities:  

Mesh:

Year:  2002        PMID: 11834145

Source DB:  PubMed          Journal:  Clin Sci (Lond)        ISSN: 0143-5221            Impact factor:   6.124


  33 in total

1.  Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis.

Authors:  Sebastiaan A Bartels; Wim J Stok; Rick Bezemer; Remco J Boksem; Jeroen van Goudoever; Thomas G V Cherpanath; Johannes J van Lieshout; Berend E Westerhof; John M Karemaker; Can Ince
Journal:  J Clin Monit Comput       Date:  2011-10-15       Impact factor: 2.502

Review 2.  [Hemodynamics and physical capacity in patients with left ventricular assist devices : An overview].

Authors:  N Reiss; M Altesellmeier; S Mommertz; T Schmidt; S Schulte-Eistrup; D Willemsen
Journal:  Herz       Date:  2016-02-11       Impact factor: 1.443

3.  Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients.

Authors:  Liang Dong; Jian-an Wang; Chen-yang Jiang
Journal:  J Zhejiang Univ Sci B       Date:  2005-12       Impact factor: 3.066

4.  Comparison of cardiac output determined by different rebreathing methods at rest and at peak exercise.

Authors:  Djordje G Jakovljevic; David Nunan; Gay Donovan; Lynette D Hodges; Gavin R H Sandercock; David A Brodie
Journal:  Eur J Appl Physiol       Date:  2007-12-11       Impact factor: 3.078

5.  Reproducibility of cardiac output measurement by the nitrous oxide rebreathing technique.

Authors:  Philip J Peyton; Michael Bailey; Bruce R Thompson
Journal:  J Clin Monit Comput       Date:  2009-06-19       Impact factor: 2.502

6.  Non-invasive haemodynamic assessments using Innocor during standard graded exercise tests.

Authors:  Piero Fontana; Urs Boutellier; Marco Toigo
Journal:  Eur J Appl Physiol       Date:  2009-10-29       Impact factor: 3.078

7.  A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output.

Authors:  Frederik Trinkmann; Manuel Berger; Ursula Hoffmann; Martin Borggrefe; Jens J Kaden; Joachim Saur
Journal:  Clin Res Cardiol       Date:  2011-07-01       Impact factor: 5.460

8.  Non-invasive measurement of hemodynamic response to postural stress using inert gas rebreathing.

Authors:  Ksenija Stach; Julia D Michels; Christina Doesch; Joachim Brade; Theano Papavassiliu; Martin Borggrefe; Ibrahim Akin; Joachim Saur; Frederik Trinkmann
Journal:  Biomed Rep       Date:  2019-07-18

9.  Cardiac output by pulse contour analysis does not match the increase measured by rebreathing during human spaceflight.

Authors:  Richard L Hughson; Sean D Peterson; Nicholas J Yee; Danielle K Greaves
Journal:  J Appl Physiol (1985)       Date:  2017-08-10

10.  Comparative Noninvasive Measurement of Cardiac Output Based on the Inert Gas Rebreathing Method (Innocor®) and MRI in Patients with Univentricular Hearts.

Authors:  Miriam Kuhn; Andreas Hornung; Heidi Ulmer; Christian Schlensak; Michael Hofbeck; Gesa Wiegand
Journal:  Pediatr Cardiol       Date:  2018-02-03       Impact factor: 1.655

View more