Literature DB >> 28749700

Radiographic diagnosis of root fractures: a systematic review, meta-analyses and sources of heterogeneity.

Fernanda Cristina Sales Salineiro1, Solange Kobayashi-Velasco1, Mariana Minatel Braga2, Marcelo Gusmão Paraiso Cavalcanti1.   

Abstract

OBJECTIVES: Many studies to evaluate the accuracy of root fracture diagnosis have been conducted. However, there is a scarcity of studies to assess the quality and the sources of heterogeneity in the literature. For this reason, the aim of this study was to conduct systematic reviews and meta-analyses to summarize the available evidence on detection of root fractures by cone beam CT (CBCT) and periapical radiograph (PR) images and the interference of artefact by investigating possible sources of heterogeneity.
METHODS: Studies reporting root fracture detection, from January 2010 to February 2016, were selected. All selected studies were subjected to selection criteria and then, comparative and qualitative analyses by using the quality assessment of diagnostic accuracy studies (QUADAS-2) tool were performed. Pooled sensitivity, specificity and diagnostic odds ratios were calculated. Also, receiver operator characteristics (ROC) curves were built to summarize the results. SROC curve analyses were performed to investigate the heterogeneity among studies.
RESULTS: Initially, 799 articles were selected. After screening titles and abstracts, 743 articles were excluded. After reading the remaining 56 full-texts, 47 relevant articles were included in this study. Diagnostic odds ratio values revealed a wide range of results across the studies and determined a higher heterogeneity for PR compared with CBCT. The analyses of the SROC curves compared CBCT imaging versus PR in the diagnosis of root fracture, favouring CBCT modality.
CONCLUSIONS: CBCT was the imaging exam that rendered a higher diagnostic accuracy for root fractures.

Entities:  

Keywords:  cone-beam computed tomography; imaging diagnosis; root fracture

Mesh:

Year:  2017        PMID: 28749700      PMCID: PMC5965946          DOI: 10.1259/dmfr.20170400

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  51 in total

Review 1.  Diagnostic accuracy of CBCT for tooth fractures: a meta-analysis.

Authors:  Hu Long; Yang Zhou; Niansong Ye; Lina Liao; Fan Jian; Yan Wang; Wenli Lai
Journal:  J Dent       Date:  2013-12-07       Impact factor: 4.379

2.  What is cone-beam CT and how does it work?

Authors:  William C Scarfe; Allan G Farman
Journal:  Dent Clin North Am       Date:  2008-10

3.  Performance of an artefact reduction algorithm in the diagnosis of in vitro vertical root fracture in four different root filling conditions on CBCT images.

Authors:  G L de Rezende Barbosa; S L Sousa Melo; P N B Alencar; M C C Nascimento; S M Almeida
Journal:  Int Endod J       Date:  2015-06-26       Impact factor: 5.264

4.  Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth.

Authors:  B Bechara; C Alex McMahan; W S Moore; M Noujeim; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

5.  Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth.

Authors:  B Bechara; C A McMahan; M Noujeim; T Faddoul; W S Moore; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-04-26       Impact factor: 2.419

6.  Detection of vertical root fractures in vivo in endodontically treated teeth by cone-beam computed tomography scans.

Authors:  Maria Elissavet Metska; Irene Helena Adriana Aartman; Paul Rudolf Wesselink; Ahmet Rifat Özok
Journal:  J Endod       Date:  2012-06-30       Impact factor: 4.171

7.  A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth.

Authors:  E Brady; F Mannocci; J Brown; R Wilson; S Patel
Journal:  Int Endod J       Date:  2013-12-11       Impact factor: 5.264

8.  QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies.

Authors:  Penny F Whiting; Anne W S Rutjes; Marie E Westwood; Susan Mallett; Jonathan J Deeks; Johannes B Reitsma; Mariska M G Leeflang; Jonathan A C Sterne; Patrick M M Bossuyt
Journal:  Ann Intern Med       Date:  2011-10-18       Impact factor: 25.391

9.  Comparison of periapical radiography with cone beam computed tomography in the diagnosis of vertical root fractures in teeth with metallic post.

Authors:  Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli da Silva; Sergio Sabio; Paulo Ricardo Febrairo Albino
Journal:  J Conserv Dent       Date:  2014-05

10.  Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system.

Authors:  Mahdis Mohammadpour; Neema Bakhshalian; Shahriar Shahab; Shaya Sadeghi; Mona Ataee; Soodeh Sarikhani
Journal:  Imaging Sci Dent       Date:  2014-06-11
View more
  15 in total

1.  Assessment of fractures in endodontically treated teeth restored with and without root canal posts using high-resolution cone beam computed tomography.

Authors:  David Aristizabal-Elejalde; Luis-Ernesto Arriola-Guillén; Aron Aliaga-Del Castillo; Gustavo-Armando Ruíz-Mora; Yalil-Augusto Rodríguez-Cárdenas
Journal:  J Clin Exp Dent       Date:  2020-06-01

2.  Determination of a cone-beam CT low-dose protocol for root fracture diagnosis in non-endodontically treated anterior maxillary teeth.

Authors:  Fedil Andraws Yalda; Chrysoula Theodorakou; Rosalyn J Clarkson; Jonathan Davies; Lee Feinberg; Anita Sengupta; Keith Horner
Journal:  Dentomaxillofac Radiol       Date:  2021-09-08       Impact factor: 2.419

3.  The detection of vertical root fractures in post-core restored teeth with cone-beam CT: in vivo and ex vivo.

Authors:  Svetlana F Byakova; Nina E Novozhilova; Irina M Makeeva; Vasiliy I Grachev; Inna V Kasatkina
Journal:  Dentomaxillofac Radiol       Date:  2019-05-24       Impact factor: 2.419

4.  Evaluation of an artificial intelligence system for detecting vertical root fracture on panoramic radiography.

Authors:  Motoki Fukuda; Kyoko Inamoto; Naoki Shibata; Yoshiko Ariji; Yudai Yanashita; Shota Kutsuna; Kazuhiko Nakata; Akitoshi Katsumata; Hiroshi Fujita; Eiichiro Ariji
Journal:  Oral Radiol       Date:  2019-09-18       Impact factor: 1.852

5.  Influence of the exomass on the detection of simulated root fracture in cone-beam CT - an ex-vivo study.

Authors:  Amanda Pelegrin Candemil; Francesca Mangione; Karla Farias Vasconcelos; Anne Caroline Oenning; Reinhilde Jacobs; Deborah Queiroz Freitas; Francisco Haiter-Neto; Benjamin Salmon; Matheus Lima Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2020-12-11       Impact factor: 2.419

Review 6.  Two decades of research on CBCT imaging in DMFR - an appraisal of scientific evidence.

Authors:  Hugo Gaêta-Araujo; André Ferreira Leite; Karla de Faria Vasconcelos; Reinhilde Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2021-02-15       Impact factor: 2.419

7.  Does anthropomorphic model design in ex vivo studies affect diagnostic accuracy for dental root fracture using CBCT?

Authors:  Fedil Andraws Yalda; Rosalyn J Clarkson; Jonathan Davies; Peter G J Rout; Anita Sengupta; Keith Horner
Journal:  Dentomaxillofac Radiol       Date:  2020-06-09       Impact factor: 2.419

Review 8.  Diagnosis of cracked teeth using cone-beam computed tomography: literature review and clinical experience.

Authors:  Antian Gao; Dantong Cao; Zitong Lin
Journal:  Dentomaxillofac Radiol       Date:  2021-04-29       Impact factor: 3.525

9.  Diagnostic efficacy of cone beam computed tomography in paediatric dentistry: a systematic review.

Authors:  K Horner; S Barry; M Dave; C Dixon; A Littlewood; C L Pang; A Sengupta; V Srinivasan
Journal:  Eur Arch Paediatr Dent       Date:  2019-12-19

10.  Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study.

Authors:  Ava Nikbin; Zahra Dalili Kajan; Mehran Taramsari; Negar Khosravifard
Journal:  Imaging Sci Dent       Date:  2018-12-20
View more